background image

Service Manual
No-Frost
Combi-Refrigerator

Models:

ERF-366N, 366A 
ERF-396N, 396A 

ERF-416N, 416A

DAEWOO ELECTRONICS
MANUFACTURING ESPAÑA, S.A.

Содержание ERF-366A

Страница 1: ...Service Manual No Frost Combi Refrigerator Models ERF 366N 366A ERF 396N 396A ERF 416N 416A DAEWOO ELECTRONICS MANUFACTURING ESPA A S A...

Страница 2: ...GS 3 REAL VIEW 4 MACHINE ROOM VIEW 5 REFRIGERANT CYCLE 6 TEMPERATURES DIAGRAM 7 WIRING DIAGRAMS 8 PCB CIRCUIT DIAGRAMS 9 COMPONENTS DISASSEMBLY PICTURES 10 DOOR POSITION CHANGE PROCESS 11 EXPLODE DRAW...

Страница 3: ...1765 1896 1896 1985 1985 Width 600 600 600 600 600 600 Depth 642 642 642 642 642 642 N N N N N N 70 70 74 74 76 76 Net weight kg Freezing capacity kg 24h Climate class Star rating Rated input A Divisi...

Страница 4: ...R 17 Bottle pocket 18 Guide bottle pocket 19 Multi pocket 20 Adjustable foot 1 Shelves ERF 366 N 2EA ERF 396 N 3EA ERF 416 N 3EA 2 Knob control 3 Multi duct 4 Shelf of low temp compartment 5 Low temp...

Страница 5: ...3 REAL VIEW 4...

Страница 6: ...4 MACHINE ROOM VIEW 5 SCREW MACHINE...

Страница 7: ...5 REFRIGERANT CYCLE 6 CAPILLARY TUBE...

Страница 8: ...Refrigerator Low temp compartment 3 C Vegetables compartment 0 C 5 C Freezer SUPER 0 C HIGH 1 C MID 3 C LOW 5 C VAC 6 C SUPER 23 C HIGH 22 C MID 20 C LOW 18 C VAC 16 C 6 TEMPERATURES DIAGRAM 7...

Страница 9: ...7 WIRING DIAGRAMS 8 7 1 ERF XX6A...

Страница 10: ...7 2 ERF XX6N 9...

Страница 11: ...8 PCB CIRCUIT DIAGRAMS 10 8 1 ERF XX6A...

Страница 12: ...8 2 ERF XX6N 11...

Страница 13: ...ter sleeve between Window FCP and Panel F control Important Input carefully cutter in the area that picture shows down right Lift Window FCP up Remark Input cutter deeply and carefully in order to lif...

Страница 14: ...to the left side and input a thin driver in the rigth part as picture shows After this operation lift switch up Remark Input driver carefully in order to lift up easily and avoid paint damages and sc...

Страница 15: ...ctors from M pcb and force plastic locker of pcb box in order to take out the pcb Remark In ERF xx6N models forced defrost button is located in M PCB so pcb box cover must be disassembled 4 RELAY BOX...

Страница 16: ...I DUCT Take out window r pulling the top part sleeve Unscrew all fixing screws To disassemble V PCB force left plastic stopper and lift pcb up To disassemble R sensor lift it up from the wires careful...

Страница 17: ...the two fixing screw for disassembly louver A and B Disconnect fan motor housing Unscrew the fixing screw in order to disassemble Louver A 16 TO DIASEMBLE IT IS NECESSARY A STAR DRIVER WITH A MINIMAL...

Страница 18: ...ck Knob F louver position Default position is M 7 CHANGE DOOR OPEN SIDE Unscrew cover T hinge Before changing door open side disconnect door housing connector Follow next sheets instructions to change...

Страница 19: ...M 4 Remove F door 5 Remove COVER BRACKET 6 Remove HINGE U 7 Reverse the position of COVER BUSHING 8 Move R DOOR HANDLE to F DOOR 9 Reverse the position of CAP DR BUSHING 10 Move F DOOR HANDLE to R DOO...

Страница 20: ...Reverse the position of HINGE M and CAP SCREW HOLE 1 Attach the R DOOR 15 Attach the HINGE T on the left of cabinet after assembling to R DOOR 16 Reverse the position of COVER HINGE and COVER CAB HAR...

Страница 21: ...11 EXPLODE DRAWING 20...

Страница 22: ...21...

Страница 23: ...0100 1 1 1 1 1 1 BLUE MILKY 20 DECO M DUCT COVER 3011633200 1 1 1 BLUE 21 SENSOR R AS 3012731800 1 1 1 1 1 1 22 COVER T HINGE DMS1494310 1 1 1 1 1 1 SNOW WHITE DMS1494320 1 1 1 1 1 1 03 SILVER 23 HING...

Страница 24: ...UE MILKY 50 POCKET MULTI AS 3019026200 1 1 1 1 1 1 BLUE MILKY 51 CAP HANDLE 3010910000 4 4 4 4 4 4 SNOW WHITE DMS0910030 4 4 4 4 4 4 03 SILVER 52 HANDLE F 3012639800 1 1 1 1 1 1 03 SILVER DMS2639810 1...

Страница 25: ...IAL SCREW A 3016004300 4 4 4 4 4 4 82 CAPACITOR RUN DMS6402129 1 1 1 1 1 1 83 SPECIAL WASHER R C DMS6006510 1 1 1 1 1 1 84 SPECIAL NUT R C DMS6006410 1 1 1 1 1 1 85 RELAY BOX DMS0527900 1 1 1 1 1 1 86...

Страница 26: ...WHEN TEMP CONTROL S W IS PRESSED 4 TIMES 5 SUPER STEP LED ON WHEN TEMP CONTROL S W IS PRESSED 5 TIMES 6 ERROR LED DISPLAY ON MAIN PCB FUNCTION DISPLAY D1 ERROR LED is off on one time D2 ERROR LED is o...

Страница 27: ...2 1 COMP will be controlled by the on off condition of each mode 2 2 STEP DIFF of ROOM R Vac Low 1 75 deg Low Middle 0 7deg Mid High 1 05deg High Super 1 4 deg 2 3 OFF point of ROOM R in MID position...

Страница 28: ...t 1 2 Process General operation Heater on Pause 6min General operation Heater defrosts When the temperature at D sensor is over 10 C heater turns off Limit time 80 min 30 min on D SENSOR ERROR 2 Force...

Страница 29: ...is on 4 2 CONTROL The system is normally operating but the controlling by RT SENSOR doesn t work 4 3 CANCEL when RT SENSOR is working normally 5 DR ERROR 5 1 Display LED is on continuously 5 2 Contro...

Страница 30: ...set the initial mode How to clear press REF TEMP button 5 time with pressing POWER button 15 FUNCTION OF LOW ROOM TEMPERATURE 1 Condition of LOW RT TEMP 1 1 LOW RT A RT SENSOR 14 C 1 2 LOW RT B 15 C...

Страница 31: ...F POINT Variation C 0 5 C DEF 1 0 C down 2 0 C down 3 0 C down 1 0 C up 2 0 C up 3 0 C up R26 R27 Resistan ce kOhms Jumper adoption R27 40 R26 10 R27 23 3 R26 10 R27 15 R26 10 R27 10 R26 10 R27 3 5 R2...

Страница 32: ...e 0 7 deg 28 Total step Difference 6 3 deg ERROR LED DISPLAY ON MAIN PCB DISPLAY LED FUNCTION DISPLAY D1 ERROR LED is off on one time D2 ERROR LED is off on two times R1 ERROR LED is on off one time R...

Страница 33: ...rolled by the on off point of R Sensor at each mode 2 2 STEP DIFF of ROOM R 1 4 deg 2 3 Middle OFF point of ROOM R 0 15 C 2 4 ON OFF DIFF of ROOM R 3 deg ON OFF 2 85 0 15 5 65 2 65 0 05 2 95 1 25 1 55...

Страница 34: ...termination of defrost 1 2 Process General operation Heater on Pause 6min General operation Heater defrost When the temperature at D sensor is over 10 C heater turns off Limit time 80 min 30 min on D...

Страница 35: ...ISPLAY On off two times while LED is on 4 2 CONTROL The system is normally operating but the controlling by RT SENSOR doesn t work 4 3 CANCEL when RT SENSOR is working normally 5 DR ERROR 5 1 Display...

Страница 36: ...perating Temperature 1 C up LOW RT TEMP B Condition R SENSOR Operating Temperature 16 R SENSOR OFF POINT ADJUSTING OPTION 1 R Sensor OFF Point can be adjusted by changing the input voltage of Micom 26...

Страница 37: ...J2 CHANGING R OFF POINT 1DEG UP MICOM 26 port 2 5V LOW COOLING OPTION a R SENSOR OFF POINT ADJUSTMENT 1 DEG DOWN b J1 DELETION onLOW COOLING OPTION Default resistance 31 4KOhms 1 5 KOhms 32 9 KOhms O...

Страница 38: ...DAEWOO ELECTRONICS MANUFACTURING ESPA A S A Pol gono industrial de J ndiz C Zurrupitieta 27 01015 Vitoria Spain Tel 00 34 945292292 Fax 00 34 945290965...