![Daewoo DWM-7510 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/daewoo/dwm-7510/dwm-7510_service-manual_4114168016.webp)
15
Problem
Check Point
Cause
Solution
Draining does not
function during
drain selecting.
Draining does not
function during
Spinning.
Is the Drain Selector in the DRAIN
position?
Is the pump Motor wiring properly
connected?
The position is fault.
Defective wiring.
Defective wiring.
Defective Spin Timer.
Defective Pump Motor.
Reconnect wiring.
Reconnect wiring.
Replace Spin Timer.
Replace Pump Motor.
NO
NO
NO
NO
YES
YES
YES
Are the wiring of the Spin Timer and
the Pump Motor good?
Is the Spin Timer contact good?
Turn the Drain Selector
to DRAIN.
Defective Pump Motor.
Replace Pump Motor.
YES
Problem
Check Point
Cause
Solution
Drainage is not
satisfactory.
Are there impurties in the Drain Strainer?
Impurities are obstrusting
drainage.
Disassemble Pulsator and
take out impurities in Drain
Strainer.
Impurities are obstrusting
drainage.
Remove impurities or replace
Valve Housing or Inlet Joint.
Are there impurities in the Valve Housing
or Inlet Joint?
Impurities are blocking the
Drain Hose.
Remove impurities.
Water Keeps
Draining during
wash.
Is the Drain Selector DRAIN position
on the panel.
The position is fault.
Turn the Drain Selector to
WASH/RINSE position.
There are impurities
between Valve Housing
and Valve Bellows.
Remove impurities or
replace Valve Housing.
YES
NO
NO
NO
YES
YES
Concerning Drainage (NON PUM P)
Содержание DWM-7510
Страница 17: ...16 6 EXPLODED VIEW AND PARTS LIST ASSY PANEL BACK...
Страница 19: ...18 ASSY TUB PUMP MODEL...
Страница 21: ...20 ASSY MAIN...
Страница 25: ...24 7 WIRING DIAGRAM 7 1 SINGLE VOLTAGE NORMAL 7 2 SINGLE VOLTAGE PUMP...
Страница 26: ...25 7 3 DUAL VOLTAGE NORMAL 7 4 DUAL VOLTAGE PUMP...