PRINCIPLES OF OPERATION AND EXPLANATION OF FUNCTIONS
Problem
Check Point
Cause
Solution
Problem
Check Point
Cause
Solution
There are strange
noise and severe
vibration during
spinning.
There is leakage
during spin drying.
Spin Dryer does
not stop with the
open.
Door Spin *O
Drainage is not
satisfactory.
Does the Brake Band touches the Drum
coupling when the Door Spin *O open.
Is the electric connection of the Door
Switch good?
Brake wire is too short
Brake Band is w orn out.
Defecive Door Switch
Replace D oor Switch
The Drain Hose is too High.
Im purities are obstructing
drainage.
Im purities are obstructing
drainage.
Im purities are blocking the
Drain Hose.
Replace Brake Band or
Brake Fix Assembly.
Hang the Drain Hose lower
Disassemble Pulsator and
take out impurities in Drain
strainer
Rem ove impurities or
replace Case Valve or
inlet joint.
Rem ove impurities
Is the Bellow s Assem bly properly
assem bled?
N O
NO
NO
NO
NO
YES
YES
YES
YES
Is the height of the drainage area where
the Drain H ose hangs over 1m?
(pump m odel)
Are there impurities in the Drain Strainer?
Are there im purities in the case valve or
Inlet Joint.
The Waterseal or the Oilless metal in the
Bellows Assembly worn out.
Waterproofing not working
due to defective assembly.
The waterseal or the oilless
metal in the Bellows
Assembly is worn out.
Replace Bellows Assembly
Re-assemble Bellows
Assembly.
Replace Bellows Assembly.
Assemble after loosening
Link Brake and adjusting
upward.
The contact of the D oor
switch does not open due
to deformity of the Lever
of Door Switch.
Replace D oor Switch or
reshape the Lever of
Door Switch.
YES
YES
YES
NO
Concerning Drainage
Содержание DWM-500M
Страница 6: ...WIRING AND CIRCUIT DIAGRAM 1 SINGLE VOLTAGE NONPUMP MODEL 2 DUAL VOLTAGE NONPUMP MODEL 5 ...
Страница 7: ...WIRING AND CIRCUIT DIAGRAM 3 SINGLE VOLTAGE PUMP MODEL 4 DUAL VOLTAGE PUMP MODEL 6 ...
Страница 20: ... EXPLODED VIEWS 1 PANEL ASS Y ...
Страница 21: ... EXPLODED VIEWS 2 TUB ASS Y ...
Страница 22: ... EXPLODED VIEWS 3 BASE ASS Y ...