12
EXPLANATION
FUNCTIONAL PRINCIPLE
1 The micom can remember the time from the begining of drain to reset point when the pressure switch reaches to
“OFF” point
2 In case of continuous draining, residual drain time is determined by micom.
Draining time as a whole = D + 40
Residual drain time.
The time remembered by micom.
Draining
Good draining
The washer begins spin process after drainage.
condition
Bad draining
Draininig time is prolonged.
No draining
Program is stopped and gives the alarm.
Drain Time
Movement of the Program
Less than
Continue draining
10 minutes
More than
Program stops and gives the alarm with
blinked on display lamp.
10 minutes
Automatic Drainning time Adjustment
This system adjusts the draining time automatically according to the draining condition.