Daewoo DWF-805M Скачать руководство пользователя страница 9

8

FEATURE

FUNCTIONAL PRINCIPLE

The micom can remember the time from the begining of drain to reset point when the pressure switch reaches to

“OFF” point

In case of continuous draining, residual drain time is determined by micom.

Draining time as a whole = D + 90

Residual drain time.
The time remembered by micom.

FUNCTIONAL PRINCIPLE

Bubble Motor supplies the air from the bottom of outer tub to the inner space of pulsator, the air is dispersed by the
rotation of pulsator. Air-bubble is created by the centrifugal force, and rises up.

Draining

Good draining

The washer begins spin process after drainage.

condition

Bad draining

Draininig time is prolonged.

No draining 

Program is stopped and gives the alarm.

Drain Time

Movement of the Program

Less than

Continue draining

15 minutes

More than

Program stops and gives the alarm with 

blinked on display lamp.

15 minutes

FUNCTIONAL PRINCIPLE OF BUBBLE WASHING MACHINE

ACROSS SECTION

AUTOMATIC DRAINNING TIME ADJUSTMENT

This system adjusts the draining time automatically according to the draining condition.

Air bubble

Tub

Outer tub

Pulsator

Содержание DWF-805M

Страница 1: ...Service Manual Auto Washer Model DWF 805M DAEWOO ELECTRONICS CO LTD...

Страница 2: ...R 4 HOW TO INSTALL ON AN INCLINED PLACE 4 HOW TO CONNECT THE INLET HOSE 5 HOW TO CLEAN THE FILTER 6 4 FEATURE AND TECHNICAL EXPLANATION 7 FEATURE OF THE WASHING MACHINE 7 WATER CURRENT TO ADJUST THE U...

Страница 3: ...78 4N cm2 50Hz 9 60Hz 10 PULSATOR 6 WINGS 376mm 11 WATER LEVEL CONTROL ELECTRONICAL SENSOR 12 GEAR MECHANISM ASS Y HELICAL GEAR 13 LINT FILTER O 14 SOFTENER INLET O 15 FUNCTION OF SOAK WASH O 16 ALAR...

Страница 4: ...EDRAIN FORPUMP COVER UNDER OPTION HOSE DRAIN CLAMP WATER TAP ADAPTER HOSE DRAIN FOR NONPUMP INLET HOSE CONNECTORINLET OPTION Accessories U P The parts and features of your washer are illustrated on th...

Страница 5: ...d on an unsuitable floor it could make considerable noise and vibration INSTALLING PLACE N Ne ev ve er r i in ns st ta al ll l i in n t th he es se e p pl la ac ce es s 2Push the noise insulation plat...

Страница 6: ...ap tightly HOW TO CONNECT THE INLET HOSE Be careful not to mistake in supplying between the hot maximum 50 C and cold water In using only one water tap or in case of attached one water inlet valve con...

Страница 7: ...cleaned at proper time every 10 times of use Drain problem could be caused 3Return the filter as it was and insert the filter frame into the slot 1Pull the Filter frame upward 2Turn the lint filter in...

Страница 8: ...the unbalanced load 7 One touch operation system WATER CURRENT TO ADJUST THE UNBALANCED LOAD It is a function to prevent eccentricity of the clothes after wash by rotating pulsator C W and C C W for 3...

Страница 9: ...d by the rotation of pulsator Air bubble is created by the centrifugal force and rises up Draining Good draining The washer begins spin process after drainage condition Bad draining Draininig time is...

Страница 10: ...h due to the serious vibration and the spin process is interrupted 3 In case that P C B ASS Y gets OFF signal from the safety switch spin process are stopped and rinse process is started auto maticall...

Страница 11: ...hen operation is finished the TIME INDICATOR will light up STRUCTURE FUNCTIONAL PRINCIPLE 1 When the DRAIN MOTOR connected to the power source the DRAIN MOTOR rotates with 900 r p m and revolves the p...

Страница 12: ...witch is inferior The load sensing is inferior After the load sensing operates about 7 seconds the message is displayed during 0 5 second and water level is always fixed high The water level sensing i...

Страница 13: ...27V 220 240V RATING REFER TO RATING PLATE AC SOURCE BK or BR WH or BL GN or GN YW FUSE A BL YW WH BK BL WH RD WH RD WH RD WH RD WH RD BL YW BK GN WH BK WH BR BR YW PK VT VT BL VT MOTOR DRAIN MOTOR COL...

Страница 14: ...TING V 110 127V 220 240V RATING REFER TO RATING PLATE AC SOURCE BK or BR WH or BL GN or GN YW FUSE A BL YW WH BK BL WH RD WH RD WH RD WH RD BL YW BK GN WH BK WH BR BR PK VT VT BL VT MOTOR DRAIN MOTOR...

Страница 15: ...TO RATING PLATE AC SOURCE BK or BR WH or BL GN or GN YW FUSE A BL YW BL WH WH BK BL WH RD WH RD WH RD WH WH RD RD BL YW BK GN WH BK WH BR BR YW PK VT VT BL VT MOTOR DRAIN MOTOR HOT WATER VALVE PUMP MO...

Страница 16: ...31 PARTS DIAGRAM PARTS DIAGRAM...

Страница 17: ...32 PARTS DIAGRAM...

Страница 18: ...33 PARTS DIAGRAM...

Страница 19: ...INA 3611304910 VCTF 3X0 75 2 3M INDIA 3611305310 H05W F 3X0 75 2 3M WH MALAYSIA 3611305410 H05W F 3X0 75 2 3M BK SINGAPOLE 3611305810 H05W F 3X0 75 2 3M GY SOUTH AFRICA 3611305610 F H05W 3X0 75 2 3M B...

Страница 20: ...1600MM PUMP B03 SCREW TAPPING 7122401211 TRS 4X12 MFZN 4 B04 PLATE UPPER 3614519400 PP 1 B05 SUPPORTER TUB BL 3615302931 FRPP 5203G6 1 B06 SCREW TAPPING 7112401211 T1 TRS 4X12 MFZN 8 B07 SUPPORTER TU...

Страница 21: ...A L 184 1 PUMP C21 HOSE OVERFLOW 3613208901 PE LD L 280mm 1 NON PUMP C22 SPECIAL BOLT 7341601611 6B 16X16 MFZN 2 C23 HARNESS EARTHINNER 3612757010 L 560mm 1 C24 SPECIAL SCREW 3616006900 SCM24H 6 5X18...

Страница 22: ...37 PARTS DIAGRAM CIRCUIT DIAGRAM NON PUMP SINGLE VALVE...

Страница 23: ...38 CIRCUIT DIAGRAM CIRCUIT DIAGRAM NON PUMP DUAL VALVE...

Страница 24: ...39 CIRCUIT DIAGRAM CIRCUIT DIAGRAM PUMP DUAL VALVE...

Страница 25: ...DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 82 32 510 7628 TEL 82 32 510 7630 http www dwe daewoo co kr PRINTED...

Отзывы: