![Daewoo DWF-160M Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/daewoo/dwf-160m/dwf-160m_service-manual_499207023.webp)
22
7. TECHNICAL POINT
Valve Drain Assy and Gear Mechanism
Replacing Process of Synchronous Motor Wire
We changed the shape of the Lever because of preventing water leakage and noise of G/M.
Please refer to the changing date as following table
OLD type
NEW type
Valve Drain Assy
G/M with Tub O
Part name
Part Cord
Specification
Part Cord
Specification
Plate valve conn’r
4509k78070
SECC
–
Link valve drain
–
3617801900
POM
G/M
3617305821
GM-1300-KJ6XO
3617307610
GM-1300-KS6PO
Syncronous Motor
4505D45100 L =56.5/18mm(110-130V/60Hz) 4505E45120 L=64.5/23mm(110-130V/60Hz)
3966010200 L =56.5/18mm(220-240V/50Hz) 3966010220 L=64.5/23mm(220-240V/50Hz)
– replace the New G/M
– replace the Link valve drain
from Plate valve connector
– insert the Link v/v drain into the G/M Lever with pulling the Lever toward
Syncronous Motor
– to assemble the wire of Syncronous Motor to the inside of Link valve
drain with pulling the Lever toward Syncronous Motor
Содержание DWF-160M
Страница 32: ...31 WIRING DIAGRAM APPENDIX è Wiring Diagram non pump ...
Страница 33: ...32 WIRING DIAGRAM è Non Pump Single Valve ...
Страница 34: ...33 WIRING DIAGRAM è Pump ...
Страница 35: ...34 PARTS DIAGRAM è Parts Diagram ...
Страница 36: ...35 PARTS DIAGRAM ...
Страница 37: ...36 PARTS DIAGRAM ...
Страница 42: ...41 PARTS DIAGRAM è Circuit Diagram Non Pump ...
Страница 43: ...42 CIRCUIT DIAGRAM è Circuit Diagram Non Pump Single Valve ...
Страница 44: ...43 CIRCUIT DIAGRAM è Circuit Diagram Pump ...