41
TROUBLESHOOTING GUIDE
MESSAGE
ERROR
CAUSE
SOLUTION
H5 WATER TEMP.
ERROR
The water temp. is over 45˚C in delicate & wool course.
(The thermistor wash is an inferior product or broke down.)
Change the thermistor wash.
H6 HEATER WASH
ERROR
The heater wash dose not work.
(The water temp. doesn't rise over 2˚C during 15min.)
Change the heater wash.
H8
HEATER WASH
OVERHEATING
ERROR
The heater worked without the water in the tub.
Check the water level and the heater wash.
lb
IGBT
ERROR
The PCB ASSʼY is an inferior product.
Change the PCB ASSʼY.
PFE PUMP FILTER
ERROR
The drain pump filter is clogged.
Clean the drain pump filter.
The drain pump does not work during spin.
Change the drain pump.
The large amount of detergent was used.
Use the proper amount of detergent.
The drain hose is placed higher than 1m above the floor.
Place the drain hose 1m below the floor.
HP HIGH POWER
ERROR
HP ERROR occurs when the input power is more than
280V
Hp error disappears below the 270v input
voltage.