background image

Содержание DWD-1211RT

Страница 1: ...JUL 2005 Model DWD 1211RT DWD 1221RT DWD 1223RT WDE1211001 DRUM WASHING MACHINE ...

Страница 2: ...OF DRUM WASHING MACHINE 6 3 VERIFICATION OF DRUM ASSY 7 4 PARTS LIST FOR EACH ASSY 8 5 SEQUENCE CHART OF PCB 20 6 SPECIFICATION OF ELECTRONIC PARTS 28 7 WIRING DIAGRAM 47 8 TROUBLESHOOTING REGARDING DRAIN 49 9 INSTALLATION GUIDE 50 10 ATTENTION POINT WITH SERVICE 52 ...

Страница 3: ... 99 9 No damage and entanglement but excellent washability 4way savings noise vibration washing times energy Self cleaning course of Drum Good washing performance with heating system Condensing dry system with saving energy Sunshine dry effects with infrared x ray Big door glass with easy laundry take in out The higest spin speed 1200rpm No use of Drain pump good quality of drain and low noise 2 S...

Страница 4: ...3 DD CONTROL DIRECT DRIVE TYPE BLDC MOTOR 3 THE DRIVE SYSTEM OF DRUM WASHING MACHINE TUB DRUM LIFTER WASH BLDC DRAIN MOTOR ...

Страница 5: ...PREWASH 5 DOOR부 DOORLOCKS W WATERADDINGFUNCTION LOCKHINGE DOORAS GLASS GASKET 7 DRAIN DRAINMOTOR VALVEHOUSING 6 DRY PARTS HEATERDRY 1200W BLOWERFAN FANMOTOR BLDC THERMISTOR THERMOSTAT FUSE BI METAL CONDENSINGSYSTEM DRYFANDRIVE GENERATIONOF HEATER SHEAT TEMP SENSOR 95 OFF87 ON ...

Страница 6: ...CB FRONTPCB HARNESS NOISEFILTER POWERCORD 15A 2 DRIVE PARTS BLDCMOTOR DRUM BEARING SPIDER SHAFT TUB WEIGHTBALANCER 4 WASH HEATING WASHHEATER 1000W THERMISTOR 30 FIXEDTEMP CONTROL 50 60 BOIL 8 SUPPORTER BASE DAMPERAS 3 70N ...

Страница 7: ...3 INLET PARTS 3 WAYINLETVALVE 2 WAYINLETVALVE INLETBOX 1 CONTROLLER FRONTPCB NOISEFILTER MAINPCB 5 DOOR AS GLASS HINGE DOORLOCKS W GASKET 7 DRAIN DRAINMOTOR VALVEHOUSING HOSE 8 SUPPORTER BASE DAMPERAS 3 70N SPRING 4 ...

Страница 8: ...OR SHAFT BEARING SPIDER DRUM TUB WEIGHTBALANCER 4 WASH HEATING WASHHEATER THERMISTOR RAIN RAINMOTOR ALVEHOUSING OSE 6 DRY DUCT AS BLDC MOTOR DRIVE PARTS 2 ROTATION FAN FANMOTOR HEATERDRY BI METALS W TEMP SENSOR TEMP FUSE ...

Страница 9: ...YPE DRUMTYPE DRYTYPE Digitalcondensingdrysystem OPERATIONWATERPRESSURE 29kPa 784kPa 0 3 f cm2 8 f cm2 NO PARTS NAME 1 FRME DOOR O 2 DOOR WINDOW 3 DCD STICKER 4 PANEL LOWER 5 CABINET FRONT 6 PANEL LOWER 7 FRAME TOP F 8 FRAME TOP R 9 CABINET 10 PLATE TOP 11 CASE HANDLE 12 HANDLE CAP 13 BADGE 14 WINDOW DISPLAY 15 DECO WINDOW 16 BUTTONDOORUNLOCK 17 BUTTON FUNCTION 18 DECO FUNCTION 19 PLATE DISPENSER 2...

Страница 10: ...7 3 VERIFICATION OF DRUM ASSY PLATE TOP ASS Y 7 EA INLETBOX ASS Y PANEL F ASS Y CABINET F ASS Y 19 EA PANEL 1 20EA PANEL 2 17 EA ...

Страница 11: ...7 BASE U AS 8 EA TUB AS 29 EA CABINET AS 10 EA DUCT B AS A DUCT PIPE 23 EA ...

Страница 12: ...NT 3611139500 PP 1 D04 CAPSOFTENER 3610916600 PP 1 D05 INLETBOX 3617505310 FRPP 1 D06 NOZZLEAS3618103510NOZZLETOP UNDER 1 D07 PACKING 3614010000 EPDM 1 D08 HOSEINLET3613266400 EPDM 1 INLETBOX TUBR D09 CLAMPAS 3611203200 SWC SPC ID 60 2 PREWASH D10 HOSEC 3613267000 EPDM ID 10 OD 16 L 355mm 1 WASHING D11 HOSEA 3613266600 EPDM ID 10 OD 16 L 335mm 1 D12 CLAMPSPRING 3611203800 ID 15 5 4 D13 VALVEINLET ...

Страница 13: ...ABS 1 B08 DECORATORFUNCTION 361163900 ABS 1 B09 BUTTONFUNCTION 3616602700 ABS 1 SCREWTAPPING 7121301208 T2SPAN3X12SUS 3 B10 WINDOWDISPLAY 3615502700 ABS 2 B11 DECORATORWINDOW 3611630800 ABS 1 B12 HOLDERPOWER 3613048800 ABS 1 B13 HOLDERCOURSEMAIN 3613049100 ABS 1 B14 BUTTONDIALMIDDLE 3616602400 ABS 1 B15 BUTTONDIALOUT 3616602500 ABS 1 B16 BUTTONDIALIN 3616602300 ABS 1 B17 CUSTOMLED 3613014400 ABS 1...

Страница 14: ...TTONPOWER 3616603100 ABS 1 B06 BUTTONDOOROPEN 361603200 ABS 1 B07 BUTTONFUNCTION 3616603000 ABS 1 SCREWTAPPING 7121301208 T2SPAN3X12SUS 3 B08 HOLDERLEDCOURSE 3613049300 ABS 1 B09 HOLDERLEDCUSTOM 3613049200 ABS 1 B10 CASEPCBF3611139600 HIPS 1 SCREWTAPPING 7122401411 T2STRS4X14MFZN 7 B11 PCB PRPSSW2D10 DWD E1221RT 1 B12 BUTTONDIALOUT 3616603400 ABS 1 B13 BUTTONDIALIN 3616603300 ABS 1 B14 WINDOWDISPL...

Страница 15: ...11 3 THE EXPLODED VIEW OF CABINET F ASSEMBLY ...

Страница 16: ...AMEDOORI 3612204700 TB53 Heat ResistancePP 1 C09 STOPPERDOOR 3615202300 TB53 Heat ResistancePP 3 C10 SCREWTAPPING 7115401608 4X16 SUS 3 C11 SCREWTAPPING 3606001310 4X20 12 C12 DOORGLASS361A110600 GLASS 1 C13 PROTECTORGLASS 3618304200 1 C14 FRAMEDOORO 3612204600 ABS CRCOATING 1 FRAMEDOORO 3612204610 ABS UVSPRAY 1 C15 COVERHANDLE 3611425600 ABSMP0160 1 C16 SPRINGHOOK 3615113700 SUS ID 4 5 1 C17 PINH...

Страница 17: ... DWD E1223RT 1 PCBAS PRPSSW2D04 DWD E1221WT DWD E1223WT 1 G02 LINEFILTERAS 3611908000 EMI 1 G03 BASEU 3610391900 PP 1 G04 TRANSSMPS DWD 5EM1028010 T2S V24 600uH 1 3 1 G05 SUPPORTERLEG 3615303600 PO Coating 3 0T 4 G06 FIXTURELEG 3612006400 ABS 4 G07 FOOT 3612100600 BUTYL 4 SPECIALBOLT 3616029000 10X1 25 51MM 4 4 THE EXPLODED VIEW OF BASE U ASSEMBLY ...

Страница 18: ...14 5 THE EXPLODED VIEW OF TUB ASSEMBLY ...

Страница 19: ...UMAS 3617003300 SUS 1 H13 LIFTAS 361A400300 1 H14 SPIDERAS 361A300200 AL S45C 1 H15 DRAINMOTOR 36196TAK00 SV HJ7T20D100 110V 1 H16 VALVEDRAINAS 3615415100 ASSY 1 H17 AIRTRAPAS3610AAR100 1 H18 SPRINGSUSPENSIONR 3615113600 BLACK 2 H19 GASKETTUBE 3612321100 EPDRFORM 1 H20 WATERSEAL361A600100 EPDM 1 H21 BEARINGI 3616303100 6506 1 H22 BEARINGHOUSING 3616303000 AL 1 H23 BEARINGO 3616303200 6205 1 H24 HO...

Страница 20: ...16 6 THE EXPLODED VIEW OF DUCT B AS A DUCT PIPE ASSEMBLY WASH ...

Страница 21: ... E09 FRAMEHEATERFRANGE 3612204100 SBHG1 0t 1 E10 DUCTBLOWER 361A200100 AL 1 E11 PACKINGTHERMOSTAT 3614009900 SILICON 1 E12 SWITCHTHERMOSTAT 3619046500 ON120 OFF150 230V15A 1 E13 HEATERDRY3612801300110V1 2KW23 0Ω6 1W SQINCOLOY800RL89 1 E14 THERMISTORDRY 361AAAAC00 CWT DEW 1C03 1 E15 PACKINGRUBBER 3614009800 SILICON 1 E16 CUSHIONDRY 3611562800 NBR 2 E17 GASKETSEALA 3612320800 EPDMFOAM 1 E18 GASKETSE...

Страница 22: ...3612204900 GI 1 6T 1 F04 CABINET 3610810900 SGCC 0 8T PAINTING 1 F05 COVERBACK 3611425500 0 4T SGCC 1 F06 STOPPERSPRING 3615202200 POM 4 F07 FRAMECOVER 3612205000 SGCC1 2T 1 F08 FRAMEUPPER 3612204000 SBHG 1 2T 1 F09 HANDLECABINET 3612608100 PP 4 F10 FRAMELOWER 3612204200 SBHG 1 2T 1 F11 SENSORPRESSURE 3614825200 5VDRUM DL DW01 1 F12 CORDPOWERAS 3611339810 VCTFK2C15A125V 1 ...

Страница 23: ...04400 ABS 1 A02 FRAMEPLATER 3612204500 ABS 1 A03 PLATETOP3614531600 MFC3244g 1 A04 PADCUSHION 3614110500 SPONGE 1 A05 FIXTUREPLATET 3612007100 STAPLE 12 A06 CAUTIONSTICKER 3613553800 ART OPP 1 SCREWTAPPING 7122401411 T2STRS4X14MFZN 2 8 THE EXPLODED VIEW OF PLATE TOP ASSEMBLY ...

Страница 24: ...er Supply 2min Rinse 1 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 1min 7min Main Spin 5min 3min Cloths Release 60sec END 10sec Wrinkles Protect 30min Over Time Indication 1 32 1 37 1 34 1 59 2 27 2 37 1 47 2 02 NOTE Pre Wash 預 預洗 洗 W a s h i n g 洗 洗 衣 衣 R i n ...

Страница 25: ... Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 1min 7min Mid Spin 5min 3min 포풀림 60sec Dry 40min 18min Cooling 5min END 10sec Wrinkles Protect 30min Cloths Release 60sec END 10sec Over Time Indication 46 46 1 07 1 15 1 48 NOTE W a s h i n g 洗 洗 衣 衣 R i n s e 洗 洗 淸 淸 S p i n D R Y 烘 烘 乾 乾 End Blanket Delicate 高 高級 級衣 衣物 物 Wool 毛 毛衣 衣 Quick30 快 快洗 洗 Drain 槽 槽洗 洗淨 淨 Memory 記 記憶 憶 1 Quick30 ...

Страница 26: ... Rotatingthesame45rpmwithleftandrightdirectionalternatively Attachingstop Attachingthelaundrytodruminsidewithconstantspeed Unbalancecheckingpoint Firststep checktheU Bat95rpm 160rpm Secondstep checktheU Bat95rpm 350rpm Thirdstep at300rpm iftheunbalancedataisoverthecriterion Thisprocesswillberepeated Drainstep Drainatwateraround160rpm Afterdrain checktheunbalancedataagain Thisisso calledbalancespin...

Страница 27: ...id supply20msecpulse untilunlock Afterdoorlocking allpartscanworknormally After pressing power button if the temperature of wash thermistor is over 50 or the water level is over the safety level thedoorwillbelocked Thedoorthewillbeunlockedimmediatelyafterallprocessesarefinished Thedoorcanbeopenedduringprocessingifthereisnoproblemtounlock ...

Страница 28: ...N Display LOCK off Dooropen drain fanmotoron coldwatersupply waterlevelis lessthansafetylevel NO NO YES YES Temperatureis lessthan50 2 DOOROPENSYSTEM Ifaddthelaundryduringwashing pressthedoorunlockbutton Dooropensequenceatabnormalcondition ...

Страница 29: ...nordentounlockChildLockmode press TEMP and DRY simultaneously 2 5 Thesequenceofdrain Ifthecheckingtimetoresetpointisbelow1min theremainingdraintimeis30sec Ifthecheckingtimetoresetpointisover1min theremainingdraintimeis2min Ifthecheckingtimetoresetpointisover10min OEsingalwillbeappearedonPCB Ifthetemperatureisover50 thewaterwillbesuppliedtohighwaterlevel thenthedrainwillstart ...

Страница 30: ...urnon LOCK singal allprocessisconductingnormaly Whenworkingstarts thePCBdisplysallthesensorconditions Inthiscase BLDCMotorisnottested Inordertotestit selectspinorrinse 2 Continoustestingmode 1 Process afterpressing WASH RINSE SPIN buttonsimultaniously press POWER button ALLLEDOn Off1time L C LockClosed R Motorright L MotorLeft F FanMotor H HotV V C ColdV V b pre washV V d dryV V bb bubble h1 HEATE...

Страница 31: ...hugenoise re installation E5 HIGHVOLTAGE spiningwithjammingclothesbetweengasket rearrangethelaundry ERROR PCBbroken ChangethePCB hugenoise re installation E6 EMGERROR spiningwithjammingclothesbetweengasket rearrangethelaundry motorbroken ChangetheMotor PCBbroken ChangethePCB E7 DirectionError moveoppositedirection motorHallICbroken checktheconnectorandchange E8 motordisorder connectorproblem Theco...

Страница 32: ...801100 110V1KW12 1Ω4 3W SQSUS1R1A03305144 IR1A033005 11 HEATERDRY 110 50 60 3612801300 110V1 2KW23 0Ω6 1W SQINCOLOY8001R1A034001 IR1A034005 12 SWITCHTHERMOSTAT 100 250V 3619046500 ON120 OFF150 230V15AVDE NT 103NA UNITMOTORBLDC 36189L4000 3254D02000 3114D02000 310V 250W 3254D02000 13 UNITSTATORBLDC A11 36189L4800 Φ265X28H 36SLOT 25NESOR 3254D02000 3114D02000 UNITROTORBLDC 36189L4900 MAGNET24 SERRAT...

Страница 33: ...8s VDE FUSE128 DF128S15A 250V TUBESRGT ID Φ5 WH L WUL1015AWG18105 600V DF PA66 IMQCA02 01619 BI METAL SOLEN0ID PA6625 GFV0 ICOWS W BI M 16A125V SOLENOID125V130Ω PTCHEATER IR1A033005 SUS321 VDE72709 THERMAL THERMALFUSE167 TUBEAISI321 SUS321 FUSE BRACKET Mg0INSULATION SEALANTEPOXY120 1 IR1A034005 INCOLOY800 VDE62726 BRACKET TUBEINCOLOY800 INSULATIONMg0 GASKETSILICONE INSULATINGBUSHINGCERAMIC SEALANT...

Страница 34: ...ℓ 7 12ℓ 8 13ℓ 8 13ℓ 8 13ℓ VALVE 3 WAY 3615415000 IVORY PP MAINWASH 4320 5280Ω 2 5ℓ 7 12ℓ 8 13ℓ 8 13ℓ 8 13ℓ VALVE VALVE DRYVALVE 4320 5280Ω 0 2 1 2ℓ PRE WASH 4320 5280Ω 2 5ℓ 7 12ℓ 8 13ℓ 8 13ℓ 8 13ℓ 2 WAY 3615414900 BLUE PP VALVE VALVE MAINWASH 4320 5280Ω 2 5ℓ 7 12ℓ 8 13ℓ 8 13ℓ 8 13ℓ VALVE 0 2kgf 1 0kgf 3 0kgf 5 0kgf 8 0kgf ...

Страница 35: ...mbled Openthewatertap Cleanthefilter ChangetheInlet Valve Thecontactofthe Connector ChangetheInlet Valve ChangetheSensor Pressure Changethebad parts ChangetheInlet Valve ChangetheInlet Valve IE IE IE IE IE IE IE E2 E2 checkthewatertapopened checktheresistance4320 5280Ω checkthefilter checktheconnector checktheresistance4320 5280Ω checktheconnector checkthepressureswitch checkthehosetornortwisted c...

Страница 36: ...e changethehose removethealien reconnecting changethe pressureswitch E2 E2 E2 E2 E9 E9 E9 frequencyCheck refertobelow frequencyCheck refertobelow checkthefinehole checkthehosecondition checktheconnectorcondition frequencyCheck refertobelow connectorbroken Checkingmethodofcoilregistance harness connector E2 overflowerror Waterlevelishigherthanoverflowlevelbecauseofcontinuouswatersupply E9 Pressures...

Страница 37: ... CloseDoorsecurely ReplaceDOORAS ReplaceDOORS W AssembleConnector InsertReceptacleno 2 orno 3 ReplaceDOORS W Afterdrainingwater openthedoor LE LE LE LE LE LE LE checkthejoiningstatusof connectorbyeye Ticksoundhappen checkthejoiningstatusof connectorbyeye Refertobelowchecking method Refertobelowchecking method Checkwhetherthewater levelisoversafetylevel WhenDoorislocked unlocked thisSolenoidWorking...

Страница 38: ...33 2 CheckingmethodofDOORLOCKSWITCH 3 CheckingmethodofDOORLOCKSWITCH 2345 Nono 1 BetweenNo 3 No 4 if156 234Ω itisnormal BetweenViloetandBluewire If156 234Ω itisnormal PIN array ...

Страница 39: ...d in heater SUS430 361280110 heater dry IRCA 110V 1200W 5 10 08 3 5 128 exterior exterior INCLOY800 3612801300 1 Temperaturefuse Iftheheaterisonwithoutwater becauseofpressureswitchtrouble firecanbeoccurred Temperaturefusepreventsthishazardoffire Theheaterwashmustbesubmergedinwater 2 Thedeviceforoverheatingpreventionofthedryheater Temperaturefuse 128 cut offtype 250V15A Thermostat 150 off120 on 230...

Страница 40: ...ndsis23 3 25 7Ω Checkwhetherdisconnectedornot SeeFig A Measuretheresistanceoftwoendsofthesensor refer totheattachedtemp resistancetable Measuretheresistanceoftwoendsofthesensor refer totheattachedtemp resistancetable Checkwhetherdisconnectedornot SeeFig B Checkwhetherdisconnectedornot ifnormal the resistancebetweentwoendsis22 3 24 7Ω ShippedoutChecktheconnectionoftwoendsoffuse temp Checkwhetherdis...

Страница 41: ...torDryOPEN SHORT 2 H2 ThermisterWashOPEN SHORT 3 H3 DryOverheating SensingTemp isover125 4 H4 WashOverheating SensingTemp isover95 5 H5 Wash Overheating InWool Lingeriecoursessensingtemp isover45 6 H6 Abnormal condition of Heater Wash whenthetemp increaseat10minutesafterheateroperationisunder10 7 H7 Abnormal condition of Heater Dry when the temp increase at 10 minutes afterheateroperationisunder10...

Страница 42: ...rivingmechanismofBLDCMOTOR BLDCMOTOR의구성 MagneticdensityflowofBLDCMotor SequencediagramofBLDCMOTOR 5 MOTOR Rotor Insulator Core Insulator electromagnet generatinghighpowerbyrotator apermanentmagnet andstator multiplecoils ...

Страница 43: ...1 DRY SYSTEM F H I A B C D E G J DIVISION PARTSNAME A DUCTCOVER B FANMOTOR C HEATERDRY D DUCTBUNDER E VALVEINLET DRY F THERMOSTAT Bie METAL G THERMISTOR H DUCTBUPPER I FANAS J FUSETEMPERATURE 6 DRY SYSTEM ...

Страница 44: ...T andcondensedinDUCTcontactingWATERSUPPLY condensedwater isextractedthroughDRAINHOUSING Dryfunctionisperformedbycontinuousrepetitionofevaporatingandcondensingcirculationasabove DRY DUCT T Thermistor CONTROL HEATER S TEMPERATURE HEATER FANMOTOR CONDENSING DUCT DRUM DRAIN HOUSING 온도 건조진행구간 예열 구간 DRUM 내부온도 시간 T WATER SUPPLY INSIDE TEMPERATURE OF DRUM TIME DRYING PROCESS ZONE TEMP PREHEATING ZONE ...

Страница 45: ...7 On 95 Off dryingtimeis166min STRONG Heatercontroltemperatureis87 On 95 Off dryingtimeis216min SELECTINGTIME Heatercontroltemperatureis87 On 95 Off customercanselectthedrytingtimeas 1Hr 2Hr 3Hr Inordertocheckthedryingtemperatureduringprocessgoingon pressthe DRY button the display shows as below 남은시간 분 UPPER LED TemperatureforDRY Thecurrenttemperatureis98 LOWERLED TemperatureforWASH REMAINTIME ...

Страница 46: ...nsingtheairtemperature FAILUREMODE Theaircannotbeheatedeventhoughwaterissupplied H1 shotorcut off H3 airtemp isreachedover150 CHECKINGMETHOD Checktheresistanceofthermistor replacewithnewone FUSETEMPERATURE function protectingfromthefinehazardoroverheating ifthetemp risesover128 powersupplywillbecut off Pictures FAILUREMODE Dryisnotperformed CHECKINGMETHOD Checkiffuseisshort andreplacewithnewone FI...

Страница 47: ...er150 andreoperatingheater byconnectingheaterpowersupplyifthetemperaturefallsunder120 OPERATINGTEMPERATURE PICTURE UNITFANMOTOR function circulatingtheinsideairduringdryprocess SPEC PICTURE FAILUREMODE E3shown FANMOTORcannotwork CHECKINGMETHOD ChecktheFANMOTORisshort andreplacewithnewone OPEN TEMPERATURE OFF 150 5 CLOSETEMPERATURE ON 120 5 ITEMS SPEC RATING VOLTAGE 24V RPM MOTOR 3700 10 DUCTFANAS ...

Страница 48: ...drayfromceramicparticlecoatingonDUCT BUPPER principle DUCT B UPPER FAR INFRAREDCOATING DUCT B UPPER heatedair emitfar infrared f a r i n f r a coatingarea steilization The far infrared ray is emitted from the ceramic coating comes into drum by radiation and reflection and penetrates deeply into laundry with the effective moisture removal and sterilization pass tubinside ...

Страница 49: ...asdonebeforethedryhadstarted Situation PCBshows H1 or H3 cause Thermistorisbroken Thermistorisshortorcut off countermeasures replacetheThermistor part name checking point checking results jurge repair method BELLOWS DUCT VALVE INLET Condensing HOSE clogging bellowsduct nowatersupply frominletvalve heaterwas overheated owingtopoorair circulation VALVEINLET connectorslipped out VALVEINLET broken ill...

Страница 50: ...ryheater replacetheFusetemp checking point part name checking results repaire method HEATER SENSORTEMP FUSETEMP dryHeaterisshortorcut off Thermistorisshortorcut off FUSETEMPERATUREiscut off replacethe dryHeater replacethe Thermistor replacethe FUSE TEMPERATURE HEATER THERMISTOR FUSE TEMPERATURE ...

Страница 51: ...orfailure replace fanmotor DisassembletheDUCTASfromDUCTBAS SCREW4EA DisassembleFANASfromDUCTCOVERASbyusing L wrench DisassembleFANMOTOR SCREW3EA DUCT COVER AS 2 5mm L wrench parts Control time MOTOR 10 sec On 10sec Off DRAIN MOTOR Continous working FANMOTOR Continousworking DRY HEATER 87 On 95 Off INLET VALVE 5sec On 20sec Off Remarks controltimesofeachpartsduringdryprocess ...

Страница 52: ...2 Hb Vdd1 U GN YW CON 0 4 CON 0 4 0 S W WH CON 010 SH WF04 1 WF10 1 WH CON 0 90 M CON 0 80 F M CON 0 50 R T WF09 1 WH WH CON 0 10 CON 0 10 B P CON 0 1 0 V D CON 0 1 0 V P WF06 WF07 WF04 WF10 WF09 WH CON 0 30 W H CON R Y W H CON F 02 CON 0 2 0 D L CON 0 30 D H WH CON F 01 CON R Y T M WF03 1 12A 125V CON P C R CON P C P REC R Y CON R Y WF03 WH WH COLD PRE U W V LOCK 2 LOCK 1 2 ß 1 ß 5V V PTC SOLENOI...

Страница 53: ... 1200W HEATER WASH 1000W WF02 WF02 1 WH Vdd1 Hb U GN YW CON 010 SH WH WF06 WF07 WF10 WF10 1 CON 0 80 F M CON 0 90 M WH CON 0 50 R T WH WH CON 0 10 CON 0 10 B P CON 0 1 0 V D CON 0 1 0 V P WF09 WF09 1 WH CON 0 30 W H CON 0 30 D H 12A 125V CON R Y W H CON 0 2 0 D L WH CON F 02 CON F 01 CON R Y T M WF03 WF03 1 WH CON P C R CON P C P REC R Y CON R Y WH COLD PRE U W V LOCK 2 LOCK 1 2 ß 1 ß 5V V PTC SOL...

Страница 54: ...theendofhosenottodipinwater 4 Checking Methods Situation OE isshownonPCB Notfinishingdrainduring10min ThewaterlevelcannotreachtoRESETPOINTduring10minofdrain HOSEDRAINI HOUSING VALVE DRAIN MOTOR VALVE AIR AS Checking Methods Check the hose drain O condition twisted or frozen Check the hose drain O condition blocked DRAIN MOTOR is broken Replacing methods replace HOSE DRAIN O clean the inside of COV...

Страница 55: ... AS by turning CCW direction Please keep FIXTURE UP DOWN AS for later use When fixing FIXTURE UP DOWN AS turn it CW direction PARTS NAME FIXTUREUP DOWNAS UNIT SERVICE WRENCH LEG ADJUST AS REMARKS SPECIAL SCREW UP L 109mm SPECIAL SCREW DOWN L 145mm Usethisparttoremove FIXTUREUP DOWN Adjustlegwiththispart FIGURES SPECIAL SCREW UP FIXTURE UP FIXTURE DOWN FOOT FIXTURE LEG CAP HOLDER SPECIAL SCREW DOWN...

Страница 56: ...ingLEGADJUSTAS Adjusting Method Remarks If turned CW the LEG ADJUST AS moves the washer upward If turned CCW the LEG ADJUST AS moves the washer downward Afteradjustinglevel fixSPECIALBOLT Adjusting Method Remarks Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration ...

Страница 57: ...blingconditionbetween fixtureheateristight littlegaponleft right At fasteningthenutforfixingtheheaterwash keeptheprotrusionlengthof boltto10 12mm ifunder10mm watercanleak andifover12mm fixtureheatercandeform 7 Replacing ThermistorWash UnfastentheNutforfixingheater replacethethermistor and ThermistorWash fastenthenutforfixingheater 8 Assembling HingeDoor AtfasteningscrewforfixingDoorAS becarefulsot...

Страница 58: ...2005 05 DRUM WASHING MACHINE 본사 서울마포구아현동686 소비자상담실 대표 360 8282 http www dwe daewoo co kr ...

Страница 59: ...SVCGUIDE DWD E1211RT DWD E1211WT DWD E1221RT DWD E1221WT DWD E1223RT DWD E1223WT 2005 05 DRUM WASHING MACHINE DRUMWASHINGMACHINE ...