5. GENERAL INFORMATIONS

1. CHANGING AIR FLOW DIRECTION

Air flow deflectors divert air from center flow to left or right.
Adjust deflectors for desired air flow pattern.

2. AIR FLOW AROUND UNIT

Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil
should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed
or deflected back into unit, the compressor may cycle on and off rapidly, causing early compressor failure.

3. Electrical Grounding Instructions.

This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-
prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-
prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National
Electrical Code.

4. USE OF EXTENSION CORDS

Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension
cord. However, if you still elect to use an extension cord, it is absolutely necessary that it is earthed and the marked
rating of the extension cord should be 250V 10A or more for Model DWB-052C.
Also, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord rated has a 3-
blade grounding and 3-slot receptacle that will plug into appliance. The marked rating of the extension cord should be
125V 13A or more, for Model DWC-052C.

5. DRAIN HOLE AND WATER DRIPPING OUTSIDE

Locate drain hole at the rear of unit. Water in base pan is picked up by the fan blade and thrown onto the warm
outdoor coil where it evaporates. The air conditioner must be installed level or tited or slightly to the outside for proper
water disposal. On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear
drain hole or overflow. This should be considered normal.

Содержание DWC-052C

Страница 1: ...ATIONS 3 3 NAMES OF MAJOR COMPONENTS 4 4 FUNCTION OF MAIN COMPONENTS 5 5 GENERAL INFORMATIONS 6 6 CARE AND MAINTENANCE 7 7 TROUBLE SHOOTING GUIDE 8 8 HOW TO DISASSEMBLE 10 9 WIRING DIAGRAM 11 10 REFRI...

Страница 2: ...pair the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage p...

Страница 3: ...er Input W 525 W 520 W Running Current A 4 6 A 2 4 A Compressor Type Rotary Model RM5455GQ87 KH 091VFHC Capacitor 40 F 370VAC 13 F 400VAC Model A9520KC030 A9520CC020 Fan Motor Capacitor 4 F 370VAC 2 F...

Страница 4: ...L 3 COOL AIR DISCHARGE 4 GRILLE FRONT 5 KNOB THERMOSTAT 6 KNOB SELECTOR NO PART NAME 7 AIR INTAKE 8 AIR FILTER 9 CONTROL PANEL 10 PLATE WINDOW TOP 11 FRAME WINDOW KIT 12 SHUTTER WINDOW 2 3 8 6 5 1 4 7...

Страница 5: ...cooling operation 2 THERMOSTAT TEMPERATURE CONTROL The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level and this results in efficient use of...

Страница 6: ...accordance with the National Electrical Code 4 USE OF EXTENSION CORDS Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if...

Страница 7: ...ed servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water fir...

Страница 8: ...Disconnection 2 Malfunction of contact Disconnection or burned out 1 Failure 2 Malfunction 3 Knob is not set to the proper setting Failure of malfunction of proper setting 1 Disconnection 2 Malfunctio...

Страница 9: ...f refrigerant gas 4 Refrigerant charge is too high Clogged up with dust 1 Fin is cogged up with dust 2 The ventilation is not good 3 The unit is exposed to the sunlight 4 Other heat source is added in...

Страница 10: ...Remove wires in the Panel Housing 7 Remove screws 7 point from Ass y Fan Motor s sides Ass y Fan Motor is assembly of Fan Motor Propeller and Blower Fan Orifice and Panel Housing 8 Lift the Ass y Fan...

Страница 11: ...11 9 WIRING DIAGRAM...

Страница 12: ...Condenser Propeller fan Capillary tube Compressor Accumulator Blower fan Evaporator M MOTOR 12 10 REFRIGERANT CYCLE...

Страница 13: ...CREW TAPTITE 4 TT3 TRS 3X8 MFZN 29 3113800400 LOCK TWIST STANDOFF 1 DASTL 3NA 30 3110700100 BUSHING 1 DACB 012 73MM 31 3111400100 COVER ORIFICE 1 PP M540 32 3111800200 FAN PROPELLER 1 ABS GF 33 311450...

Страница 14: ...DWB 052C DWC 052C EXPLODED DIAGRAM...

Страница 15: ......

Страница 16: ...DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 02 590 6291 TEL 02 360 7114 590 6151 5 http www dwe daewoo co kr PRI...

Страница 17: ...LECTRONICS CO LTD S M No DWC052C020 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please...

Отзывы: