• ELECTRICAL GROUNDING INSTRUCTIONS

This appliance is equipped with a three-prong(grounding) plug for protection against possible shock

hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified

electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall

receptacle in accordance with the National Electrical Code.

• USE OF EXTENSION CORD

Because of potential safety hazards under a certain condition we strongly recommend against the use of

an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it is

earthed and the marked rating of the extension cord should be AWG #14.

The socket-outlet shall be installed near the equipment and shall be easily accessible.

• REPLACEMENT OF SUPPLY FLEXIBLE CORD.

It the supply flexible cord is damaged, it must be replaced by the manufacturer or its service agent or

similarly qualified person in order to avoid a hazard.

ELECTRICAL REQUIREMENTS

WARNING :

To avoid death, personal injury or properly damage due to electrical shock, this unit must be grounded.

Do not under any circumstances cut or remove the round grounding prong from the plug.

Do not use a two prong adapter.

WARNING :

To avoid death, personal injury or properly damage due to electrical shock, do not use an extension cord 

or pinch the power cord.

Do not remove the warning tag from the power cord.

7

Содержание DWB-180C

Страница 1: ...wer failure during running please wait for over 3 minutes If you turn on the unit in 3 minutes it can cause trouble with the unit 9 If the air conditioner is operated without an air filter dust is not removed from the air and resultant accumulation in the unit may lead to a failure Do not forget to install the air filter 10 The air filter cleaned at least once every two weeks 11 When the unit is c...

Страница 2: ... CLEANING THE AIR CONDITIONER 6 ELECTRICAL REQUIREMENTS 7 ELECTRICAL GROUNDING INSTRUCTIONS USE OF EXTENSION CORDS 7 INSTALLATION INSTRUCTION 8 8 BEFORE CALLING FOR SERVICE 11 TABLE OF CONTENTS 2 GENERAL SPECIFICATIONS ITEM POWER SOURCE COOLING CAPACITY POWER INPUT ENERGY EFFICIENCY RATIO RUNNING CURRENT DIMENSIONS REFRIGERANT R 22 WEIGHT NET DWB 180C AC 220V 50Hz 18 000 BTU h 1800W 9 5 BTU Wh 8 0...

Страница 3: ...2 GRILL FRONT 3 CABINET 4 BLADE VERTICAL 5 KNOB THERMOSTAT 6 KNOB SELECTOR NO PART NAME 7 BLADE HORIZONTAL 8 AIR VENT 9 AIR INTAKE 10 AIR DISCHARGE 11 AUTO LOUVER SWITCH DWB 180C 3 9 0 7 4 8 q 1 2 5 6 NAMES OF MAJOR COMPONENTS 3 ...

Страница 4: ...ion The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer room temperature NOTE ECONOMICAL AND COMFORTABLE USE 1 Properly control the room temperature 2 Avoid being exposed to direct sunlight 3 P...

Страница 5: ...hole at the rear or on the bottom of unit Water in base pan is picked up by the fan blade and thrown onto the warm outdoor coil where it evaporates The air conditioner must be installed level or tilted slightly to the outside for proper water disposal On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear drain hole or overflow This should be considered n...

Страница 6: ...d detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser and Evaporator coils should be cleaned at the beginning of each cooling season Use a soft brush or vacuum cleaner to clean them making sure that the Condenser and Evaporator coils are not damaged 7 Do not use abrasive cleaners These items scrach crack...

Страница 7: ...ly necessary that it is earthed and the marked rating of the extension cord should be AWG 14 The socket outlet shall be installed near the equipment and shall be easily accessible REPLACEMENT OF SUPPLY FLEXIBLE CORD It the supply flexible cord is damaged it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard ELECTRICAL REQUIREMENTS WAR...

Страница 8: ...h position of the grill front and the cabinet is 4 point 5 Separate the latch position of the frant grill from the right side of cabinet as shown in Fig 2 6 Repeate the above No 4 and No 5 at the left side of cabinet as shown in Fig 3 7 Lift up base side of the front grill until the upper side of the front grill is separated from the cabinet as shown in Fig 4 INSTALLATION INSTRUCTIONS 8 Fig 1 Push...

Страница 9: ... the front grill do the reverse order in Page 8 INSTALLATION INSTRUCTIONS CONTINUED 9 CAUTION When the front grill is reinstalled the DOOR VENT should be in position first so that it would not be vent by grill Fig 5 Door Vent ...

Страница 10: ...wn in Fig 1 For proper drainage Rear side of the unit should be inclined about 10 15mm lower 4 Insert unit in window With 2 people lift unit and insert it into the window opening 5 Finish opening Close up the gap between unit and window using the sponge or tape for insulation as shown in Fig 1 If through the wall installation is required you may choose to consult an independent servicing DAEWOO De...

Страница 11: ...or algae formation on wet surfaces Normal for operation in humid areas Suggested Solution Set Fan Control Select to position other than OFF Confirm power cord is plugged in Wait 3 to 4 minutes and recheck compressor Clean air filter When blocked curtains blinds or furnitures etc the air flow is restricted and cooling performance is affected Thermostat is adjusted correctly Check with dealer to det...

Страница 12: ...CARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTRONICS Please keep this manual well W1 ...

Отзывы: