Daewoo DWB-072C Скачать руководство пользователя страница 17

1

■ 

DWB-092C EXPLODED DIAGRAM

Содержание DWB-072C

Страница 1: ...IONS 3 3 NAMES OF MAJOR COMPONENTS 4 4 FUNCTION OF MAIN COMPONENTS 5 5 GENERAL INFORMATIONS 6 6 CARE AND MAINTENANCE 7 7 TROUBLE SHOOTING GUIDE 8 9 8 HOW TO DISASSEMBLE 10 9 WIRING DIAGRAM 11 10 REFRIGERANT CYCLE 12 11 EXPLODED DIAGRAM AND PARTS LIST 13 16 ...

Страница 2: ...pair the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage power cord 6 Never use connecting the middle of wire after cutting the middle of wire It may cause a fire and trouble 7 Checking the insulation resistance After you complete the assembly of unit surely...

Страница 3: ...t A 3 1 3 6 Compressor Type ROTARY Model RBB070A011 RBB090A011 Capacitor 25µF 400VAC 30µF 400VAC Model YSLA 35 4N YSLA 35 4P Fan Motor Capacitor 2µF 400VAC 3µF 400VAC Indoor Fan Blower Fan Outdoor Fan Propeller Fan Refrigerant R 22 Control Capillary Charge Amount g 15 2oz 430g 18 4oz 520g Dimensions Unit W x H x D 18 9 W x14 6 H x19 5 D inch 480 W x369 H x497 D mm PACKING W x H x D 21 1 W x17 6 H ...

Страница 4: ...NAMES OF MAJOR COMPONENTS NO PART NAME 1 CABINET 2 BLADE VERTICAL 3 BLADE HORIZENTAL 4 KNOB BLADE 5 GRILLE FRONT NO PART NAME 6 KNOB SELECTOR 7 KNOB THERMOSTAT 8 AIR FILTER 9 CONTROL PANEL 1 2 8 4 3 6 9 7 5 ...

Страница 5: ...hout cooling operation 2 THERMOSTAT TEMPERATURE CONTROL The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer room temperature 3 MOTOR The motor is used to rotate the indoor and outdoor fan so th...

Страница 6: ...uired to contact a qualified electrician and have the two prong wall receptacle replaced with a properly grounded three prong wall receptacle in accordance with the National Electrical Code 4 USE OF EXTENSION CORDS Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if you still elect to use an extension cord it is absolut...

Страница 7: ...zed servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Front grill may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliance...

Страница 8: ... Disconnection 2 Malfunction of contact Disconnection or burned out 1 Failure 2 Malfunction 3 Knob is not set to the proper setting Failure of malfunction of proper setting 1 Disconnection 2 Malfunction of contact Lack of capacity Disconnection 1 The voltage exceeded allowed range 2 Capacity of wire is not sufficient Extremely high Burned out Malfunction Lack of capacity Malfunction Lack of capaci...

Страница 9: ...of refrigerant gas 4 Refrigerant charge is too high Clogged up with dust 1 Fin is cogged up with dust 2 The ventilation is not good 3 The unit is exposed to the sunlight 4 Other heat source is added in the room Installation of the unit is imperfectly done 1 Fan is contacted with obstacles 2 Fixing bolt Have a screw loose Electrical noise The front is lower than rear side 1 Insulation defect of wir...

Страница 10: ...n the each components 6 Remove wires in the Panel Housing 7 Remove screws 7 point from Ass y Fan Motor s sides Ass y Fan Motor is assembly of Fan Motor Propeller and Blower Fan Orifice and Panel Housing 8 Lift the Ass y Fan Motor from the unit 9 Remove hex nut 2 point from the shaft of Fan Motor 10 Remove Propeller Fan from the shaft of Fan Motor 11 Remove Blower Fan from the shaft of Fan Motor 12...

Страница 11: ...11 9 WIRING DIAGRAM COMP F M R C O L P BR RD OR OR GY GN Lo Hi WH CAPACITOR BR YW BL Hi FAN LO FAN LO COOL Hi COOL OFF SELECTOR SWITCH BK AC115V 60Hz 2 1 4 8 7 THERMOSTAT F S C H ...

Страница 12: ...Condenser Propeller fan Capillary tube Compressor Accumulator Blower fan Evaporator M MOTOR 12 10 REFRIGERANT CYCLE ...

Страница 13: ...1 C1220T O IDø 1 0xL400 092C 3104414621 PIPE CAPILLARY 2 1 C1220T O IDø 1 0xL400 092C 14 3100029300 ASS Y EVAPORATOR 1 2RX2CX12S P1 2 072C 3100049600 ASS Y EVAPORATOR 1 3RX2CX13S P1 4 092C 15 3100034500 ASS Y PIPE EVA OUT 1 DWC 070C 072C 3100050000 ASS Y PIPE EVA OUT 1 DWC 091C 092C 3100034410 ASS Y PIPE EVA IN 1 DWC 070C 072C 16 3104414630 PIPE EVA IN 1 1 092C 3104414640 PIPE EVA IN 2 1 092C 17 3...

Страница 14: ... HEXAGON FLANGE 52 3108502700 SEAL EVA TOP 1 F US 350X40XT5 53 3104504800 PLATE SCROLL 1 PP T30 54 3108503800 SEAL SCROLL 1 F US 115X60XT5 D G 55 7122401211 SCREW TAPPING 3 T2S TRS 4X12 MFZN 56 3106601000 SCROLL UPPER 1 EPS 57 3108502800 SEAL COND TOP 1 F US 400X30XT10 58 3100078800 CABINET ASSY 1 DWC 092C PAINT 59 3100605100 BRACKET CABINET 1 SGCC 60 3108508200 SEAL FRONT MID 1 F US 62x20xT5 61 3...

Страница 15: ...1 DWB 072C EXPLODED DIAGRAM ...

Страница 16: ...5 ...

Страница 17: ...1 DWB 092C EXPLODED DIAGRAM ...

Страница 18: ...6 ...

Страница 19: ... DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 02 590 6291 TEL 02 360 7114 590 6151 5 http www dwe daewoo co kr PRINTED DATE MAR 2005 ...

Страница 20: ...Service Manual Window Type Room Air Conditioner Model DWB 072C DWB 092C DAEWOO ELECTRONICS CO LTD ...

Страница 21: ... 2C C 0 09 92 2C C S S M M B BU UY YE ER R D DA AE EW WO OO O 1차 05 3 8 6차 2차 05 3 9 7차 일 일 정 정 3차 05 3 10 8차 4차 9차 5차 10차 제 제 판 판 인 인쇄 쇄 규 규 격 격 M ME EM MO O 0 05 5 3 3 8 8 전 전체 체신 신규 규_ _2 20 0p pa ag ge e 연 연락 락처 처 V VI IS SI IO ON N 담 담 당 당 전 전지 지현 현 TEL 02 730 0660 FAX 02 730 3788 매뉴얼의 첫장에 이 서식을 작성해주세요 ...