• CHANGING AIR FLOW DIRECTION

Air flow deflectors divert air from center  flow to left or right and up or down.
Adjust deflectors for desired air flow pattern.
AUTO SWING (DWC-100CS, DWC-121CS, DWA-122CS, DWA-150CS, DWA-151CS)

When the auto louver switch is turned to “ON” position, the vertical louvers 
automatically move right and left.
Thus, you can obtain comfortable cooling.
The vertical louvers may be stopped at any position when the auto louver 
switch is turned off.

• AIR FLOW AROUND UNIT

Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The
outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow.
If air flow is obstructed or deflected back into unit, the compressor may cycle on and off rapidly, causing
early compressor failure.

• DRAIN HOLE AND WATER DRIPPING OUTSIDE

Locate drain hole at the rear or on the bottom of unit. Water in base pan is picked up by the fan blade and
thrown onto the warm outdoor coil where it evaporates. The air conditioner must be installed level or tilted
slightly to the outside for proper water disposal. On exceptionally hot and humid days the air conditioner
may permit excess water to pass thru rear drain hole or overflow. This should be considered normal.

• HOW TO INSTALL THE DRAIN CAP

Install the drain cap like Fig. of the right side.
There are two kinds of method to install the drain cap.
The first method is that the shape of hole like 
It is good for the household.
The second method is that the shape of hole is like 
It is good for the shop.

• DOOR VENT

The door vent for the room air ventilation is lever type.
If the door vent lever moves to the left, then close the 
vent and moves to the rght, then open the vent. 

GENERAL INFORMATION

AUTO SWING

ON / OFF

The rear side of the unit

Drain Cap

SEAL DRAIN

Screw (Type D)

Close     Vent 

→ 

Open

Door Vent

Содержание DWA-122C

Страница 1: ...t 7 Wait at least 3 minutes before restarting the unit or in the case of power failure If you turn on the unit within 3 minutes after power off this can cause damage to the unit 8 If the air conditioner is operated without an air filter dust is not removed from the air and resultant accumulation in the unit may lead to a failure Do not forget to install the air filter 9 The air filter should be cl...

Страница 2: ...G CONTROL TEMPERATURE CONTROL 5 GENERAL INFORMATION 11 CHANGING AIR FLOW DIRECTION AIR FLOW AROUND UNIT DRAIN HOLE AND WATER DRIPPING OUTSIDE 6 CARE AND MAINTENANCE 12 AIR FILTER CLEANING THE AIR CONDITIONER 7 ELECTRICAL REQUIREMENTS 13 ELECTRICAL GROUNDING INSTRUCTIONS USE OF EXTENSION CORDS 8 BEFORE CALLING FOR SERVICE 14 TABLE OF CONTENTS GENERAL SPECIFICATIONS ITEM POWER SOURCE DIMENSIONS WEIG...

Страница 3: ...r room air conditioner After installing the unit re read these instructions to make sure you have completed each step and all parts are fastened in place for a secure installation For best results perform the installation procedure in the order given Doing so will minimize the time required to install the unit BASIC TOOLS NEEDED SAFETY INSTRUCTIONS IMPORTANT It is important both for your personal ...

Страница 4: ... to the National Electric Code and applicable local code BEFORE INSTALLATION Test Run Unit Plug unit into proper power supply outlet Refer to operating instructions in this manual for comfortable living Check all controls for correct operation then unplug unit Determine Correct Mounting procedure Refer to Window Installation or Through the Wall Installation WARNING An extension cord should not be ...

Страница 5: ...w sill with pencil 4 Insert Screws Type A into the sill bracket 5 Attach Sill bracket to window sill using two Screws Type B by each bracket The outside edge of window bracket should be 11 8 inch 300mm from center line 6 Adjust Screw Type A so that Sill Bracket have a slight tilt by using carpenter s level meter Step 3 Preparation of Chassis 1 Pull the Air filter out of the Front Grille 2 Loosen s...

Страница 6: ...right side of Front Grille to the right until the snap fit is released 3 Pull lower side of the Front Grille until it is separated from the chassis when knobe remain pull Front Grille until knobs are released from control 4 Push base side of the Front Grille to upper side until it is separated from the chassis 5 After front grille is removed remove two screws located in both side of chassis 6 Grip...

Страница 7: ...ndow frame This will prevent raising of the window from the outside If you have a hard wood or metal window frame a 1 8 inch pilot hole may be needed in order to drive the screws 8 Attach the Window Seal A to window see the picture shown in step 8 page 8 Step 5 Secure Window Shutter To provide a proper seal pull each expandable side Window Shutter out and up until it is tight against the window fr...

Страница 8: ...Be careful the end of ventilation bar is to be located in the gap of blade 5 Fasten Front Grille with screws 6 Insert Filter into the Front Grille 7 Push the Knobs into the control Step 8 Recheck the entire installation CONDENSOR PAN BASE WALL Screw Type B 2x2 4 pieces 38mm 15 SILL Screw Type C 3 pieces Screw Type C 2x1 2 pieces GUIDE LOWER WINDOW KIT R L Screw Type E 2x4 8 pieces Screw Type C 2 p...

Страница 9: ...B SELECTOR NO PART NAME 7 BLADE HORIZENTAL 8 AIR VENT 9 FRAME GUIDE TOP 10 FRAME WINDOW KIT 11 SHUTTER WINDOW 12 AUTOLOUVERS W DWC 100CS DWC 121CS DWA 122CS DWA 150CS DWA 151CS NAMES OF MAJOR COMPONENTS DWC 100CS DWC 121CS DWA 122CS DWA 150CS DWA 151CS 6 5 2 3 7 4 8 11 10 9 1 6 5 2 3 7 4 8 1 DWC 100C DWC 121C DWA 122C DWA 150C DWA 151C 9 ...

Страница 10: ...tops cooling operation in order to keep the room temperature at a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer room temperature OPERATING INSTRUCTIONS NOTE FOR MOST ECONOMICAL USE 1 Properly control the room temperature 2 Avoid the unit being exposed to direct sunlight Keep direct sun...

Страница 11: ...AIN HOLE AND WATER DRIPPING OUTSIDE Locate drain hole at the rear or on the bottom of unit Water in base pan is picked up by the fan blade and thrown onto the warm outdoor coil where it evaporates The air conditioner must be installed level or tilted slightly to the outside for proper water disposal On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear d...

Страница 12: ... mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser and Evaporator coils should be cleaned at the beginning of each cooling season Use a soft brush or vacuum cleaner to clean them making sure that the Condenser and Evaporator coils are not damaged 7 Do not use abrasive cleaners These items scrach c...

Страница 13: ...ely necessary that it will be a UL listed 3 wire grounding type appliance extension cord rated has a 3 blade grounding plug and a 3 slot receptacle that will plug into the appliance The marked rating of the extension cord should be 125V 13A minimum for DWC 100C DWC 100CS DWC 121C DWC 121CS and 250V 10A minimum for DWA 122C DWA 122CS DWA 150C DWA 150CS DWA 151C DWA 151CS ELECTRICAL REQUIREMENTS WAR...

Страница 14: ...faces Normal for operation in humid areas Suggested Solution Set Fan Control Select to position other than OFF Confirm power cord is plugged in Verify main power switch main circuit breaker or fuse of the unit is good Wait 3 to 4 minutes and restart the unit Clean air filter When blocked by curtains blinds or furnitures etc the air flow is restricted and cooling performance is affected Adjust ther...

Страница 15: ...ll warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer opening a new unit and finding that i...

Страница 16: ...S ROOM AIR CONDITIONER USE CARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTRONICS Please keep this manual well W1 R C US LISTED UL and CUL listed ...

Отзывы: