5.GENERAL INFORMATIONS 

 

1、CHANGING FLOW DIRECTION 
      Air flow deflectors divert air from center flow to left or right. 
      Adjust deflectors divert for desired dir flow pattern 
2、AIR FLOW AROUND UNIT 

Check indoor grill and outdoor louvers for air flow obstructions . Do not block air flow to and from unit . The outdoor 
coil  should  be  checked  and  periodically  cleaned  for  debris  that  may  collect  and  block  unit  air  flow  .If  air  flow  is 
obstructed or deflected back into unit ,the compressor may cycle on and off rapidly ,causing early. 

3、Electrical Grounding Instructions. 
      This appliance is equipped with a three-prong plug for protection against possible shock hazards .If a tow-prong wall 

receptacle  is  encountered  ,the  customer  is  required  to  contact  a  qualified  electrician  and  have  the  two-plug  wall 
receptacle replaced with a properly grounded three –plug wall receptacle with the National Electrical Code. 

4、USE OF EXTENSION CORDS 
      Because  of  potential  safety  hazards  under  conditions  we  strongly  recommend  against  the  use  of  an  extension 

cord .However ,if you still elect to use an extension cord ,it is absolutely necessary that it is earthed and the marked 
rating  of  the  extension  cord  should  be  250V  10A  or  more  for  DWA-1220R    DWA-1220C,Also  ,it  is  absolutely 
necessary that it be a UL listed 3-wire grounding type appliance extension cord rated has a 3-blade grounding and 
3-slot  receptacle  that  will  plug  into  appliance.  The  marked  rating  of  the  extension  cord  should  be  125V  13A  or 
more ,for Model DWC-0520RLE    DWC-1220R. 

 
5、  USAGE OF POWER CORD(AFCI OR LCDI) 
Testing: 
CASE 1 : Lamp exists 
1. Plug into power receptacle. 
2. If light is not on, press “RESET” button, light should turn on 
3. Press “TEST” button, light must turn off. 
4. Press “RESET” button again for use. Light should turn on.Do not use of above test fails. 
CASE 2 : Lamp not exist 
1.

 

Plug into power receptacle. Turn on Unit. 

2.

 

  2a. If unit operates normally, press “TEST” button. Unit should trip. Press “RESET” button again for use 

3.

 

.2b. If unit not operate, press “RESET” button for use. Unit should operate. Do not use if above test fails. 

 
WARNING : 

Do not remove, modify or immerse this plug. If this device trips, the cause is to be corrected before further use, see 

owners manual. 
This device must only be plugged on appropriate wall outlet.   
Do not use on extension cords. 

 
 

- 9 - 

Содержание DWA-1220C

Страница 1: ......

Страница 2: ...3 NAMES OF MAJOR COMPONENTS 4 6 4 FUNCTION OF MAIN COMPONENTS 7 8 5 GENERAL INFORMATIONS 9 6 CARE AND MAINTENANCE 10 7 TROUBLE SHOOTING GUIDE 11 12 8 HOW TO DISASSEMBLE 13 9 WIRING DIAGRAM 14 15 10 REFRIGERANT CYCLE 16 11 EXPLODED DIAGRAM AND PARTS LIST 17 21 1 ...

Страница 3: ...air the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage power cord 6 Never use connecting the middle of wire after cutting the middle of wire It may cause a fire and trouble 7 Checking the insulation resistance After you complete the assembly of unit surely ...

Страница 4: ...2 GENERAL SPECIFICATION 3 ...

Страница 5: ...3 NAMES OF MAJOR COMPONENTS DWC 0520RLE DWC 1220R DWA 1220R 4 ...

Страница 6: ...3 NAMES OF MAJOR COMPONENTS DWA 1220C 5 ...

Страница 7: ...4 FUNCTION OF MAIN COMPONENTS 1 ROTARY SWITCH SELECTOR FOR DWA 1220C 6 2 THERMOSTAT TEMPERATURE CONTROL FOR DWA 1220C ...

Страница 8: ...4 FUNCTION OF MAIN COMPONENTS 3 OPERATION PANEL FOR DWC 0520RLE DWC 1220R DWA 1220R 7 ...

Страница 9: ...e Evaporator and then discharges it back into the cool air It circulates the room air PROPELLER FAN The propeller draws outdoor air through louvering and cools Condenser and then blows the hot air out 5 CAPACITOR FOR ALL MODLE The Capacitor enlarges the difference of phase between main coil and sub coil so that the Compressor and Fan Motor starts well 6 ACCUMULATOR FOR ALL MODLE The Accumulator bl...

Страница 10: ... you still elect to use an extension cord it is absolutely necessary that it is earthed and the marked rating of the extension cord should be 250V 10A or more for DWA 1220R DWA 1220C Also it is absolutely necessary that it be a UL listed 3 wire grounding type appliance extension cord rated has a 3 blade grounding and 3 slot receptacle that will plug into appliance The marked rating of the extensio...

Страница 11: ... servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Front grill may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6...

Страница 12: ...7 TROUBLE SHOOTING GUIDE 11 ...

Страница 13: ... 12 ...

Страница 14: ... 13 ...

Страница 15: ...8 HOW TO DISASSEMBLE Please refer to the chapter 11 Exploded diagram and parts list 14 ...

Страница 16: ...9 WIRING DIAGRAM DWA 1220C DWC 1220R DWA 1220R 15 ...

Страница 17: ...9 WIRING DIAGRAM DWC 0520RLE 16 ...

Страница 18: ...ANT CYCLE 8 1 2 3 4 5 6 Cooling Air Heated Air Flow 2 Refrigerant flowing direction 7 Flow 1 1 Compressor 2 Condenser 3 Axial flow fan 4 Motor 5 Centrifugal fan 6 Vapor liquid separator 7 Capillary 8 Evaporator 17 ...

Страница 19: ...12 EXPLODED DIAGRAM AND PARTS LIST 18 DWC 0520RLE ...

Страница 20: ...12 EXPLODED DIAGRAM AND PARTS LIST 19 ...

Страница 21: ...12 EXPLODED DIAGRAM AND PARTS LIST DWC 1220R DWA 1220R DWA 1220C 20 ...

Страница 22: ...12 EXPLODED DIAGRAM AND PARTS LIST 21 ...

Страница 23: ......

Отзывы: