![Daewoo DW-5014 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/daewoo/dw-5014/dw-5014_service-manual_499104013.webp)
11
5. TROUBLE SHOOTING GUIDE
Concerning W ash
Problem
C heck Point
C ause
Solution
P ulsator does
not rotate.
Is the P ower properly connected?
Is the M otor hot?
(In case there is Thermal P rotector)
Is the W iring good?
(Refer to the W iring Diagram)
Is the contact of W ash Tim er good?
Is the Condenser properly
connected?
Motor does not start due
to opening the Condenser
circuit.
Reconnect the Power Cord.
Reconnect the Condenser.
Power restored when
Motor cools
Power has been cut off
by the Thermal Protector
Improper wiring.
Defective W ash Timer.
Defective Wash Motor.
Defect of m echanical
assembly.
Reconnect the wiring.
Replace Wash Timer.
Replace W ash Motor.
Tighten the screws fixed
on the Pulley.
Replace V-Belt
Remove impurities after
disassembling pulsator.
Replace Case Shaft A s..
Replace pulsator.
Reload with proper wash
load.
Is there a whirring sound from the
W ash Motor when turned on?
NO
NO
NO
NO
NO
NO
Y ES
YES
YES
YES
YES
Pulsator does not
rotate smoothly.
Is the wash load appropriate?
Are the Pulsator and Motor Pulley
securely assem bled?
Does the V-Belt slip?
Are there impurities between the
Pulsator and Tub.
Does the pulsator shaft rotate propely
when the pulsator has been
disassem bled?
Worn out the Serration
within the pulsator.
Defective Case Shaft As.
Worn out V-Belt.
Revolution obstructed by
im purities.
YE S
YES
YES
YE S
Y ES
NO
NO
NO
NO
NO
Note : P ull out the pow er plug prior repair and m ake sure that th e W ashing m achine has been
p roperly grounded.
Содержание DW-5014
Страница 6: ...4 3 WIRING AND CIRCUIT DIAGRAM 3 1 Single Voltage Non Pump Model DW 5014 5024 DW 5034 ...
Страница 8: ...6 3 4 Dual Voltage Non Pump Model DW 5014 5024 DW 5034 ...
Страница 9: ...7 3 5 Dual Voltage Pump Model DW 5014 5024 5034 ...
Страница 20: ...18 7 EXPLODED VIEWS PANEL ASS Y ...
Страница 21: ...19 BASE ASS Y ...
Страница 22: ...20 TUB ASS Y ...