background image

The symbols may be different from these models, but the functions are similar.

Display introduction

5

Running indicator

It lights up when the AC is running.

It flashes during defrosting.

Timer indicator

It lights up during set time.

Sleep indicator

It lights up in sleep mode.

Compressor indicator

It lights up when the compressor is on.

Display set temperature.
It shows FC after 200 hours of usage as reminder to clean the filter.
After filter cleaning press the filter reset button located on the indoor unit behind the front
panel in order to reset the display.

(

optional)

Temperature indicator

1

2

3

4

5

9

VG/VL series

Signal Receptor

   Timer

Comp. 

Run

Sleep

Super indicator

It lights up in super mode.

2

3

4

5

1

9

6

Mode indicator

Heating displays orange,others display white

7

Fan speed indicator

8

Содержание DSB-F0983ELH-V

Страница 1: ...DSB F0983ELH V DSB F1283ELH V DSB F1883ELH V DSB F2483ELH V ...

Страница 2: ...tion of parts 4 Maintenance 6 Protection 7 Troubleshooting 8 Select the installation locations 10 Indoor unit installation 11 Outdoor unit installation 15 Installation diagram 9 Air purging 15 Wiring diagram 14 Installation instructions 9 Contents 2 Preparation before use Remote controller operating instructions See remote controller instructions ...

Страница 3: ...ciency of the air conditioner if the distance longer than that length This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with ...

Страница 4: ...tive 2002 96 EC Waste Electrical and Electronic Equipment WEEE This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and col...

Страница 5: ...est the power supply cord be broken An electric shock or fire is probably caused by a broken power supply cord Never insert a stick or similar obstacle to the unit Since the fan rotates at high speed this may cause an injury Do not repair the appliance by yourself If this is done incorrectly it may cause an electric shock etc Turn off the appliance by remote control firstly before cutting off powe...

Страница 6: ... Louver Vertical Adjustment Louver Horizontal Adjustment Air Filter Remote Controller Connection Cord Pipes and Power Drain Hose Emergency Panel Display Panel Note Condensate water drains at COOLING or DRY operation Identification of parts 4 Indoor unit Outdoor unit Air Intake Front Panel ON O FF MOD E FA N SW ING SL EE P SU PE R SM AR T IFEE L DIMMER TIMER ON TIMER OF F CL OC K ON OF F ON OF F ...

Страница 7: ... lights up when the compressor is on Display set temperature It shows FC after 200 hours of usage as reminder to clean the filter After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display optional Temperature indicator 1 2 3 4 5 9 VG VL series Signal Receptor Timer Comp Run Sleep Super indicator It lights up in super mode 2 ...

Страница 8: ...Emergency button 10 10 The symbols may be different from these models but the functions are similar 5 Display introduction ON OFF To let the AC run or stop by pressing the button TLseries 2 3 4 9 1 ...

Страница 9: ...he front panel is very dirty Never sprinkle water onto the indoor unit Reinstall and shut the front panel Reinstall and shut the front panel by pressing position b downward If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment Stop the ...

Страница 10: ...e of some products is allowed beyond the range In specific situation please consult the merchant o Room temperature is below 21 C o Room temperature is below 18 C If all operation has stopped press ON OFFbutton again to restart Timer should be set again if it has been canceled Install the air conditioner at a place that can bear its weight in order to operate more quietly Install the outdoor unit ...

Страница 11: ...om working protector device The following cases may not always be a malfunction please check it before asking for service If there is strong interference from excessive static electricity discharge or power supply voltage abnormality the appliance may operate abnormally Disconnect the power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may ...

Страница 12: ...the wall should be over 500mm should be over 200 mm should be over 50mm Distance from floor over 2500mm should be should be over 250mm Installation instructions Installation diagram Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit y...

Страница 13: ...iping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page Where the air filter can be easily removed Keep the unit and remote controller 1m or more apart from television radio etc keep as far as possible from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorpti...

Страница 14: ... 3 Indoor Unit Piping Installation Install a sleeve through the wall hole to keep the wall tidy and clean Drill a hole in the wall The hole should tilt a little downward toward outside Decide the position of the hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mounting plate horizontal with a horizontal ruler or dropping line Drill holes of 32mm in dep...

Страница 15: ...slot B Press to hook the pipe fixer onto the base Base Base Base Piping fixer Piping fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe Small pipe Large pipe Thermal insulation tube Power cord Drain hose prepared by user b Pre tighten them with fingers at first then use the wrenches a Connect indoor unit pipes with two wrenches Pay special attention to th...

Страница 16: ...pecified in the power source specification 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist areas The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Chassis Cabinet Front panel ...

Страница 17: ...e only and the actual terminal shall prevail Outdoor unit Indoor unit Terminal Terminal Blue Blue Black 1 L 1 L 2 N 2 N 4 SI 4 SI Black BN BU YE GN RY1 ACIN L CN10 ACIN N Brown Indoor unit control board Indoor unit control board Evaporator YE GN YE GN 3 3 Brown Power supply BN BU YE GN RY1 ACIN L CN10 ACIN N Power supply Powerconnectingcord Powerconnectingcord Blue Gray Blue Gray B lack B la ck B ...

Страница 18: ...ll the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure demonstrates The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units release air and moisture from the refrigerant cycle using a vacuum pump as shown below 15 Installatio...

Страница 19: ...d soap or an electronic leak detector 7 Turn 2 and 3 way valves stem to fully close the valves Disconnect the flexible vacuum pump hose 8 Replace and tighten all valve caps 5 With vacuum pump still running close the low pressure knob on vacuum pump manifold Then stop the vacuum pump 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve How to Purge Ai...