28
8.Troubleshooting
8.1 Display board
Thi s indicator illuminates whe n the air conditioner i s in AUTO operation.
AU TO indicator
DE FROST indicator (F or Cooling & H eating mo dels only)
Thi s indicator illuminates whe n the air conditioner starts defrostin g automati cally or
when the warm air control fea ture is activated in he ating oper ation.
1
22
3
4
5
1
22
3
4
Displays the te mperature settings when the air condition er is operational.
This indicator fl ashe s after power is on and illuminate s when the unit is in operation.
This indicator il luminates when TIMER is set ON/OFF.
OPERATION in dicator
TIMER indicat or
TEMPERATUR E indicator
5
Signal receptor
8.2 Malfunction display
r
Extinguish
☆
Flash at 5Hz
Failure phenomenon
Operation lamp
Timer lamp
Indoor fan speed has been out of control for over 1 minute
☆
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
☆
On
Over current protection of the compressor occurs 4 times
X
☆
EEROM error
On
☆
No over-zero signal
☆
☆
Содержание DSB-075L
Страница 3: ...2 1 Features 1 1Compact design 1 2LED display ...
Страница 6: ...5 3 Dimensions 3 1 Indoor unit DSB 075L DSB 075LH DSB 095L DSB 095LH DSB 125L DSB 125LH ...
Страница 7: ...6 DSB 185L DSB 185LH ...
Страница 9: ...8 4 Refrigeration cycle diagram ...