MANUAL SWING (STEPPING MOTOR)
If the indoor fan is operating, the louver will swing or can be stopped at a preferred
location in any mode. The louver change location follow the order of :
If a command is received, the system will respond with a beep.
BUZZER
In cool mode, if Tr-Ts < 0 , indoor fan is run at low speed.
If 0 <Tr-Ts<2 , if indoor fan is running at low speed, there will be
no change in speed , if fan is running at medium speed ,there will be
no change in speed ,if indoor fan is run at high speed ,it will change
to medium speed.
If 2 <Tr-Ts<4 indoor fan keep original speed.
If Tr-Ts>4 indoor fan is run at high speed.
AUTO FAN SPEED
C
C
C
C
0
Tr-Ts
HIGH SPEED
MEDIUM SPEED
LOW SPEED
C
2 C
4 C
C
C
In heat mode, if Tr-Ts < 1 , indoor fan is run at low speed.
If 1 <Tr-Ts<3 , if indoor fan is run at low speed, there will be no
change in speed , if fan run at medium speed ,there will be no change
in speed , if indoor fan is run at high speed ,will change to medium
Speed.
If 3 <Tr-Ts<5 indoor fan keep original speed.
If Tr-Ts>5 indoor fan is run at high speed.
C
C
C
C
0
Tr-Ts
HIGH SPEED
MEDIUM SPEED
LOW SPEED
C
2 C
4 C
C
C
CONTROLS SPECIFICATION
7
7
Содержание DSA-099L
Страница 1: ...Manual de servicio Split Acondicionador de Aire Modelo ...
Страница 18: ...Exploded Views and Parts List Indoor unit 17 17 DSA 099L DSA 129L ...
Страница 20: ...Exploded Views and Parts List Outdoor unit 19 19 DSA 099L DSA 129L ...
Страница 22: ...Exploded Views and Parts List Indoor unit 21 21 DSA 189L ...
Страница 27: ...Wiring diagram 26 26 PIPE THERMISTOR ROOM THERMISTOR ...