Daewoo DOC-091R Скачать руководство пользователя страница 10

8

TROUBLE SHOOTING

1. UNIT DOES NOT

    START WHEN

    PRESSING 1/0 BUTTON

-   Water full indicator blinks, water tank

    is full.

Dump the water in the water tank.

TROUBLES

POSSIBLE CAUSES

SUGGEST REMEDIES

Reset the temperature.

Reset the temperature.

Make sure all the windows and

doors are closed.

Remove the heat sources if possible.

Connect the duct and make

sure it can function properly.

Decrease the set temperature.

Clean the air filter.

-   Room temperature is higher than

    the set temperature.(Heating mode)

-   Room temperature is lower than

    the set temperature.(Cooling mode)

-   The windows or doors in the room

    are not closed.

-   There are heat sources inside the 

    room.

-   Exhaust air duct is not connected or

    blocked.

-   Temperature setting is too high.

-   Air filter is blocked by dust.

2. NOT COOL ENOUGH

Place the unit on a flat, level

ground if possible.

It is normal.

-   The ground is not level or not flat 

    enough.

-   The sound comes from the flowing

    of the refrigerant inside the 

    air-conditioner.

4. NOISY OR VIBRATION

5. GURGLING  SOUND

Switch on again after the unit has cool down.

-   The automatic over heat protection

    function. When the temperature at 

O

O

    the air outlet exceed 70 C/158 F,the 

    device will stop.

3. POWER SHUT OFF AT

    HEATING MODE

Содержание DOC-091R

Страница 1: ...ORTABLE TYPE ROOM AIR CONDITIONER Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTR ONICS Please keep this manual well W1 R C US LISTED UL and CUL listed ...

Страница 2: ...TENTS 1 SAFETY RULES 2 NAMES OF PARTS 3 ACCESSORIES 4 OPERATION PANEL OF THE AIR CONDITIONER 5 OPERATING INSTRUCTION FOR THE AIR CONDITIONER 6 INSTALLATION 7 MAINTENANCE 8 TROUBLE SHOOTING 1 2 2 3 4 6 7 8 ...

Страница 3: ...THESE DANGERS 4 ALWAYS STORE THE UNIT UPRIGHT IN ORDER TO MAINTAIN THE COMPRE SSOR IN A PROPER CONDITION 5 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 6 THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A SOCKET OUTLET 7 IF THE APPLIANCE IS COVERED THERE IS A RISK OF OVERHEAT 8 IF THE SUPPLY TOOL OF THIS APPLIANCE IS DAMAGED IT MUST BE REPLACED BY A REPAIR SHOP APPOINTED BY THE MANUFACTURER BECAUSE ...

Страница 4: ...d please refer to the installation instructions for their usage ALKALINE BATTERIES 2 1 1 REMOTE CONTROLLER WATER PUMP DRAIN HOSE SCREWS 2 NAMES OF PARTS OPRATION PANEL AIR OUTLET REMOTE CONTROLLER CASTER REAR COVER FRONT COVER AIR INLET OUTDOOR WATER PUMP DRAIN HOSE POWER CORD AIR INLET INDOOR AIR OUTLET OUTDOOR AIR INLET OUTDOOR CONTINUOUS DRAIN HOSE FRONT VIEW SIDE VIEW REAR VIEW Fig 1 Fig 2 ...

Страница 5: ...N Turn on off the unit MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW OPERATING PANEL TEMP SETTING BUTTON Press your desired room temperature setting by pressing the button up or button down DIGITAL DISPLAY TIMER ON OFF INDICATOR TIMER ON OFF BUTTON Program the on off timer function COOL DRY FAN HEAT INDICATIO...

Страница 6: ...n off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations O O O O The operating range for cooling operating is 17 C 30 C 63 F 86 F If the cooling or dehumidifying operations have been switched off and need switching on again in a short time allow approximately three minutes for the cooling or dehumidifying operations to resume Make sure the water pump drain hose is correct...

Страница 7: ...omes on Press the FAN SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time you need the unit start to operate The Operation Paned Window will display ON The starting time is adjustable from 0 00 to 24 Setting the off timer Press the TIMER OFF button when the air conditione...

Страница 8: ...e the figures 2 Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to the arrow direction first fit the left side of the duct on the exhaust air panel then the right side duct Push it downwards be sure to fix thoroughly See the figures 2 Install the adaptor...

Страница 9: ... the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly Drain Tank Safety Feature MAINTENANCE 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2 DO NOT USE GASOLING THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT 3 DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE THE ELECTRICAL CAUE DANGER 4 IF THE POWER CORD IS DAMAGED IT SHOULD BE REPA...

Страница 10: ...mperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blocked by dust 2 NOT COOL ENOUGH Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the ...

Страница 11: ...ed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer openi...