SYMPTOM
OF TROUBLE
CAUSE OF TROUBLE
REMEDY
Bubble comes out when put
Soap-suds on welding point
Re-weld leak-point
If cut between capillary tube and
dryer, refrigerant comes out
intermittently clogged certain part
in cooling-cycle
Exchange clogged part
Door switch is not pressed
1.
Exchange door switch
pressing part or door
assembly
2.
Adjust foot cause of
Cabinet inclined
Defect motor F
Replace defect motor
Temperature-fuse is opened
Replace temperature-fuse
Defrost-heater is opened
Replace defrost-heater
Weak cooling
Defect switch bi-metal
Replace switch bi-metal
Outlet voltage is not proper
Explain customer to use
refrigerator in proper voltage
Defect fuse
Replace fuse
No power
Defect wire connection
Reconnect
Overflow the drain case
Empty the drain case
Frost is appeared around
suction pipe
Recharge proper amount of
refrigerant
Cabinet is inclined cause of
unleveled install
Use adjust feet in opposition to
former state
Leakage to
foot or front
Door inclined
Adjust all hinges
14
Содержание DIR-220
Страница 1: ...Service Manual Refrigerator Model DIR 220 DAEWOO ELECTRONICS CO LTD S M No DIR2200010 DIR 300...
Страница 4: ...2 EXTERNAL VIEWS 2 1 SIZE 1 DIR 220 3...
Страница 5: ...2 DIR 300 4...
Страница 16: ...5 DIAGRAM 5 1 WIRING DIAGRAM 1 DIR 220 2 DIR 300 15...
Страница 17: ...5 2 PRATICAL WIRING DIAGRAM 1 DIR 220 16...
Страница 18: ...2 DIR 300 17...
Страница 19: ...5 3 AIR FLOW DIAGRAM 18...
Страница 30: ...7 EXPLODED VIEW AND PART LIST 7 1 SET TOTAL EXPLODED VIEW 1 DIR 220 29...
Страница 31: ...30...
Страница 32: ...2 DIR 300 31...
Страница 33: ...32...
Страница 38: ...8 MECHANICALROOMVIEWANDPARTLIST 37...