![Daewoo 9000BTU Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/daewoo/9000btu/9000btu_service-manual_3164278024.webp)
Phenomenon
Troubleshooting
Remote controller is not available
Is the remote controller out of effective
distance to the indoor unit?
Is the battery exhausted?
Are there any obstructions between the
controller and the signal receptor?
Indoor unit does not operate
immediately when the air
conditioner is restarted
Once the air conditioner is stopped, it
will not operate in approximately 3
minutes to protect itself.
There is unusual smell blowing from
the outlet after operation is started.
This is caused by the odour in the room
permeated from building material,
furniture, or smoke.
Sound of water flow can be heard
during cooling operation
This is caused by the refrigerant
flowing inside the unit.
Mist is emitted during cooling
operation.
Mist is emitted during heating
operation.
Because the air of the room is cooled
down rapidly by the cold wind and it
looks like the fog.
This generate due to moisture in
defrosting process.
Low noise can be heard during
operation
A low hissing sound is caused by the
refrigerant flowing.
A low squeak sound is caused by the
deformation of plastic due to
temperature.
Cooling (Heating)efficiency is not
good
Is the setting temperature suitable?
Is the air inlet or outlet obstructed?
Are air filter dirty?
Is indoor fan speed set at low speed?
Is there any heat source in your room?
In case the following situation, please immediately stop all operations and cut off
the
power supply, then contact with service centre.
The fuse and switch often breaks.
Carelessly splash water or something into air conditioner.
Unusual noise can be heard during operation.
Electrical wiring and power plug are very hot.
Wind blowing from the outlet smells terrible during operation.
The Run light or other display flashes rapidly and keeps flashing after repluging.
Technical Manual of AUX Room Air Conditioner
22
Содержание 9000BTU
Страница 2: ... ...
Страница 3: ... ...
Страница 4: ... ...
Страница 5: ... ...
Страница 6: ... ...
Страница 7: ... ...
Страница 11: ...Convenient to adopt measures to reduce noises Technical Manual of AUX Room Air Comditioner 9 ...
Страница 13: ...Technical Manual of AUX Room Air Comditioner 11 ...
Страница 14: ...Technical Manual of AUX Room Air Comditioner 12 ...
Страница 34: ... Q R S T U V W X Y Z X _ S a b X c d e S f g h i j k i j k i j k ...