SERVICING PRECAUTIONS
3
◆
General Servicing Precautions
1. Always unplug the AC power cord from the AC power source before:
a. Removing or reinstalling any component, circuit board, module, or any other instrument assembly.
b. Disconnecting or reconnecting any electrical plug or other electrical connection.
c. Connecting a test substitute in parallel with an electrolytic capacitor in the instrument.
d. Discharging the picture tube anode.
2. Test high voltage only by measuring it with an appropriate high voltage meter or other voltage
measuring device (DVM, FETVOM. etc.) equipped with a suitable high voltage probe. Do not test high
voltage by “drawing an arc”.
3. Discharge the picture tube anode only by: (a) first connecting one end of an insulated clip lead to the
degaussing or line grounding system shield at the point where the picture tube socket ground lead is
connected, and then (b) touching the other end of the insulated clip lead to the picture tube anode
button, using an insulating handle to avoid personal contact with high voltage.
4. Do not any spray chemicals on or near this instrument, or any of its assemblies.
5. Unless otherwise specified in this service manual, only clean electrical contacts by applying the
following mixture to the contacts with a pipe cleaner, cotton-tipped stick, or comparable nonabrasive
applicator: 10% (by volume) Aceton and 90% (by volume) isopropyl alchohol (90%-99% strength).
6. Do not damage any plug/socket B+ voltage interlocks with which instruments covered by this service
manual might be equipped.
7. Do not apply AC power to this instrument and/or any other of its electrical assemblies unless all the
solid-state device heat sinks are correctly installed.
8. Always connect the test instrument ground lead to the appropriate instrument chassis ground before
connecting the test instrument positive lead. Always remove the test instrument ground lead last.
9. Only use the test fixtures specified in this service manual with this instrument.
CAUTION: Before servicing instruments covered by this service manual, its supplements, and
addendum, please read and follow the SAFETY PRECAUTIONS of this manual.
NOTE: If unforeseen circumstances create conflict between the following servicing precautions and any
of the safety precautions on page 1 of this manual, always follow the safety precautions.
Remember: Safety First.
CAUTION: A wrong part substitution or incorrect polarity installation of electrolytic capacitors
may result in a explosion.
CAUTION: This is a flammable mixture. Unless specified in this service manual, lubrication of
contacts is not required.
CAUTION: Do not connect the test fixture ground strap to any heatsink in this instrument.
Содержание 103FH
Страница 35: ...33 PCB LAYOUT Main PCB Component Side...
Страница 36: ...34 Main PCB Solder Side...
Страница 37: ...35 Video PCB Component Side...
Страница 38: ...36 Video PCB Solder Side...
Страница 39: ...37 Control PCB Component Side Control PCB Solder Side...
Страница 40: ...38 Socket PCB Component Side Socket PCB Solder Side...
Страница 41: ...39 SCHEMATIC DIAGRAM Power PFC Circuit...
Страница 42: ...40 MCU OSD Key Deflection Dynamic Circuit...
Страница 43: ...41 Deflection H V Circuit...
Страница 44: ...42 Video Vertical Convergence Tilt Circuit...
Страница 45: ...EXPLODED VIEW MECHANICAL PARTS LIST 43...