18
TROUBLE SHOOTING GUIDE
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Outlet has
proper voltage
Fuse does not
blow.
Check continuity of
magnetron
No
Continuity
Defective
magnetron
Replace
No
Continuity
Normal
Defective touch
control circuit
Open power
supply cord
Replace
Check continuity of
power supply cord
Adjust
Check continuity of
noise filter board
No
Continuity
Defective line
filter board
Replace
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.
NOTE
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Turn table
motor and
oven lamp do
not turn on
No
Continuity
Adjust or
replace
Adjust or
replace
Replace
Replace
Malfunction
of primary
interlock
switch
No
Continuity
0 V
Approx.
15 VDC
Check continuity of
primary interlock switch
Check continuity of
secondary interlock and
D.O.M. switches
Check D.C. voltage
being supplied to
RELAY (RY2) coil
Malfunction
of secondary
interlock and
D.O.M. switch
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY2) or open
relay coil
(TROUBLE 2)
Display shows all figures selected, but oven does not start cooking, even thouh desired program and time are
set and start pad is tapped.
Содержание KOR-633R0S
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION KOR 633R KOR 863R 365 392 279 294 465 495 ...
Страница 25: ...24 WIRING DIAGRAM ...
Страница 27: ...26 PRINTED CIRCUIT BOARD ...
Страница 28: ...27 PRINTED CIRCUIT BOARD ...