39
6) When the door is opened during operation, the count down timer does not stop.
CHECK METHOD
7) When the digital clock does not oeprate properly.
If clock does not keep exact time, you must check Diode D6, transistor Q2.
A
B
MICOM
CN2
R7
C2
R8
31
R19
+5V
C3
R6
D.O.M SW
A
B
C
MICOM
D7
D8
D6
D9
D5
R10
C7
C6
C6
R9
+5V
29
4
5
POINT
A
B
STAGE
1) DOOR OPENED
OPEN
+5VDC
2) DOOR CLOSED
CLOSED
GND
CHECK NO.
METHOD
REMEDY
1
Check the state (ON,OFF) of the secondary
Replace secondary
Interlock switch by resistance measurement.
interlock switch
POINT