12
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V.diode from the capacitor holder.
3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
DISASSEMBLY AND ASSEMBLY
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent
microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage.
It shall not exceed 4mW/ for a fully assembled oven with door normally closed.
cm
2