※ In the event of an abnormality, please refer to the error code table below and inform
us at the time of receiving repair service, so that the action may be easier.
31
30
Error code
Specification
Item
DIB-B810/DIB-B830/
DIB-B850/DIB-BE850
DIB-B810R/DIB-B830R/
DIB-B850R/DIB-BE850R
Power voltage
Max power consumption
Power cord
Supply water connection
Supply water pressure
Volume
Pressure control
Temperature control
Max heater power
consumption
Max heater power
consumption
Safety devices
Temperature control
Temperature control
Heater capacity
Safety devices
Safety device
Incoming water temperature tolerance range
Usage room temperature tolerance range
Product
dimensions
Elongated
Round
Remote dimensions
Remote weight
Product weight
Rear wash
Front wash
Turbo(enema)
Wash
Heated seat
Dry
Deodorizer
AC 220V / 60Hz
1,430W
1.8M
650±50cc/min (850±50cc/min at 2X mode)
760±50cc/min
4 levels (Off, low, middle, high)
Thermal sensor, Thermal fuse, Thermal switch
38W
5 levels
Thermal fuse
650±50cc/min (800±50cc/min at 2X mode)
Rear/Front wash (10 levels incl. 2X mode)
Turbo(enema) 5 levels
1,400W
4 levels (Off, low, middle, high)
Thermal sensor, Thermal fuse
Catalyst Carbon deodorization filter (replaceable)
400W
3 ~ 35℃ (12 ~ 35℃ recommended)
3 ~ 40℃ (10 ~ 35℃ recommended)
3 ~ 40℃ (10 ~ 35℃ recommended)
3 ~ 40℃ (10 ~ 35℃ recommended)
449mm X 528mm X 102mm 380mm X 528mm X 102mm
449mm X 500mm X 102mm 380mm X 500mm X 102mm
55mm X 177mm X 18mm
75g
4~4.5kg(6.5~7kg)
Directly connects to the water pipe
0.068 ~ 0.735 MPa
Common display
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Energy saving
“Green” and “Red”
LED sequentially
Blink, and
Night light “Red”
blinks
Left Right
Seat temperature “Green” LED blinks
Disconnected or not inserted seat temperature sensor
Low voltage
Seat temperature “RED” LED blinks
Short or overheated seat temperature sensor
Solenoid valve overcurrent
Water temperature “Green” LED blinks
Disconnected or not inserted intake water temperature sensor
Solenoid valve disconnection
Short or overheated intake water temperature sensor
Dry fan motor RPM error
Water temperature “RED” blinks
Disconnected or not inserted outlet water temperature sensor
Deodorizing fan motor overcurrent
Flow meter disconnection or abnormality
Short or overheated outlet water temperature sensor
Pump motor overcurrent
Overvoltage
Drying fan motor low/over current
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Remote model / Side arm model
Error code display priority
Error code display is divided into two sections, 1 to 6 and 7 to 15. Error with a smaller number is displayed only.
For example, if No. 1, No. 6, No. 8, and No. 15 occur simultaneously, only No. 1 and No. 8 are displayed. If 1 is
solved, only 6 and 8 will be displayed, if 8 is solved, 6 and 15 will be displayed.
Water temperature “Green” and Yellow” simulteneously
or sequentially blink
Water temperature “Green” and Yellow” simulteneously
or sequentially blink
Содержание DIB-B800 Series
Страница 18: ...WARRANTY 34 35...
Страница 19: ...www lsdaewon co kr ver 2306...