1. Before Installation 

Check that the ratings and specification of the model to be 

installed is suitable for its intended application. 

Verify that the dedicated CT being used is compatible with the 

type of Polaris. Note that the Polaris cannot be directly used with 

non-DAE dedicated CTs. 

Verify that the current rating of the dedicated CT being used is 

suitable for its intended load. 

Make sure to turn off all power sources to the Polaris and any 

adjacent power sources before performing the installation. 

Содержание Polaris 1500

Страница 1: ...DAE Controls LLC Polaris 1500 Installation Guide Ver 1 0us...

Страница 2: ...olaris 1500 Installation Guide 1 Before Installation 2 About Circuit Breaker Panel 3 Terminals 4 Mounting Procedure 5 CT Installation 6 Wiring Diagram 7 Meter Installation 8 Before Turning on the Powe...

Страница 3: ...dicated CT being used is compatible with the type of Polaris Note that the Polaris cannot be directly used with non DAE dedicated CTs Verify that the current rating of the dedicated CT being used is s...

Страница 4: ...2 About Circuit Breaker Panel VA VB VN Type 1 or 2 Phase 3 Wire Voltage VAN VBN 120V VAB 208 240V Power Source Main Circuit Breaker Branch Circuit Breakers...

Страница 5: ...VB VC VN Voltage inputs DO DO Reserved DI DI Reserved RLY RLY Reserved P P Reserved RS485 RS485 RS485 S Communications port CT A CT A Phase A CT input CT B CT B Phase B CT input CT C CT C Phase C CT i...

Страница 6: ...is wall mounted drill the screw holes according to the diagram below b Place the Polaris flat against the wall aligning the mount holes of the Polaris with the screw holes c Secure the Polaris using...

Страница 7: ...r terminal c Put the loading wire through the solid core CT d Make sure the load direction is the same as the direction marked on the CTs e Reconnect the conductor to the breaker or terminal Meter sid...

Страница 8: ...6 Wiring Diagram VAN 120V VAN VBN 120V VAB 208 240V 1 Phase 2Wire 1 or 2 Phase 3Wire Please install fuses for the voltage inputs fuse fuse...

Страница 9: ...ck that the ratings and specification of the model to be installed is suitable for its intended application 1p3w 120 208V 100A 1p3w 120 208V 200A Polaris CT current rating must be more than the main c...

Страница 10: ...Installation b Make sure to turn off all power sources to the Polaris and any adjacent power sources before performing the installation Turn off the power source Please look for the preceding circuit...

Страница 11: ...ter Installation c Attach the dedicated CTs to their corresponding terminals making sure to match phases VA VB e g 1 or 2 Phase 3 Wire Red CT Black CT Please see the Terminals and Wiring Diagram secti...

Страница 12: ...7 Meter Installation d Connect the voltage terminals of the Polaris to their corresponding phase voltages VA VB VN VA VB VN e g 1 or 2 Phase 3 Wire Please see the Terminals and Wiring Diagram sections...

Страница 13: ...voltage input cable connects to the correct terminals on the Polaris meter Check to make sure that each terminal wiring is connected properly Check that the fuse and circuit breaker are neither blown...