9.2 Local Monitoring Unit 

 

1)

 

Model 

No. 

  GMS-220 

2)

 

Max. Sensing unit number 

Max 16 

3)

 

Measurement display range     

Temperature: -40

 ~ 120

 

 

 

 

Humidity: 1% ~ 99%RH 

4)

 

Accuracy resolution 

 

Temperature: 0.1

 

Humidity: 1% 

5)

 

User interface 

▪ 

Sensor number LED 

▪ 

Temperature LED(

/’F) 

▪ 

Humidity LED(%) 

▪ 

Alarm LED 

 

Alarm 1 (Abnormal Temperature) 

 

Alarm 2 (Transmission Failure) 

▪ 

Sensor rotate switch 

▪ 

Mute button 

▪ 

Aalarm-Off Switch 

6)

 

Radio Specification 

▪ 

Frequency   426.075MHz 

7)

 

Power Supply 

 

AC Power Adapter 

▪ 

Input 

 

 

AC 110/220V, 50/60Hz 

▪ 

Output    

DC

V, 0.5A 

8)

 

Operating Range 

 

-20

80

, 80%RH

 

9)

 

Dimension 

 

 

144mm(H) x 110mm(W) x 25mm(D) 

10)

 

weight  

  184gm 

 
 

Содержание GreenOK

Страница 1: ...User s Manual Rev 2 0...

Страница 2: ...e correctness of the contents Our products are under continual improvements and we reserve the rights to make changes without prior notice Trademarks All trademarks are the properties of their respect...

Страница 3: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular install...

Страница 4: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 4 DOCUMENT HISTORY REVISION DATE COMMENTS 1 0 2003 12 22 1 ST revision created 1 1 2004 01 06 2 0 2005 07 26 GMS 120 REV B1...

Страница 5: ...FEATURES 9 3 1 WIRELESS SENSING UNIT BATTERY COVER CLOSED 9 3 2 WIRELESS SENSING UNIT BATTERY COVER OPENED 10 3 3 LOCAL MONITORING UNIT 11 4 WIRELESS SENSING UNIT 12 5 LOCAL MONITORING UNIT 19 6 SETT...

Страница 6: ...ing Refer all service to qualified service personnel Servicing your own monitor will void the warranty Contact the service contact information Do not break up or disjoint z Out of order If a problem a...

Страница 7: ...nd humidity sensor 20 to 80 and 1 to 99 And in case of using external temperature only sensor temperature operating range is 40 to 120 z You can set temperature high limit and temperature low limit to...

Страница 8: ...mperature and humidity and Local Monitoring Unit for displaying and receiving from sensing unit z Maximum 16 Wireless Sensing Units can be monitored simultaneously from a single Local Monitoring Unit...

Страница 9: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 9 3 Major Features 3 1 Wireless Sensing Unit Battery cover closed 1 TX GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 PUSH...

Страница 10: ...s Thermo Hygro Monitor User s Manual Rev 2 0 10 3 2 Wireless Sensing Unit Battery cover opened TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO...

Страница 11: ...ireless Thermo Hygro Monitor User s Manual Rev 2 0 11 3 3 Local Monitoring Unit MUTE SENSOR ID ALM OFF 1 2 3 4 5 6 7 8 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 220 SENSOR ID HUMIDITY TEMPERATURE SERI...

Страница 12: ...on Interval It is an interval that measuring results temperature humidity are transmitted Programmable transmission intervals are 1min 2min 5min 10min Factory default transmission interval is 1 min 5...

Страница 13: ...GreenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 13 Figure 2 Using the Power Switch...

Страница 14: ...Wireless Thermo Hygro Monitor User s Manual Rev 2 0 14 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 Figure 3 Setting the Se...

Страница 15: ...15 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 2min Sensor ID 10min 1min 5min Transmit Interval ON 1 2 3 4 ON 1 2 3 4 ON 1...

Страница 16: ...Thermo Hygro Monitor User s Manual Rev 2 0 16 TX SENSOR ID TEMP HI TX INT TEMP LO OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 GreenOK WIRELESS THERMO HYGRO MONITOR GMS 120 Figure 5 Selecting the External...

Страница 17: ...I ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 30 38 34 40 32 36 28 2...

Страница 18: ...TEMP LO ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 10 18 14 20 12 1...

Страница 19: ...wer limit or more than the upper limit the LED of monitoring unit blinks on red at 0 5 seconds intervals When monitoring unit can t receive any results from sensing unit over presented interval LED tu...

Страница 20: ...nsing unit and monitoring unit can be on the table or on the wall using a loop For desk or table stand up the body on a flat part For wall Hang this product using by loop on the wall 3 Setting up the...

Страница 21: ...on Must use the specified alkaline batteries and replace two batteries at a time Do not charge short break up the batteries that could Explosion and cause liquid inside out Dispose of them in an envir...

Страница 22: ...rature Sensor GMS 120E Temperature 40 120 3 Resolution Temperature 0 1 Humidity 1 4 Accuracy Temperature 1 0 80 2 20 0 Humidity 3 5 Setting DIP Switch Sensor number 1 2 8 9 10 A 16 G Transmission Inte...

Страница 23: ...ution Temperature 0 1 Humidity 1 5 User interface Sensor number LED Temperature LED F Humidity LED Alarm LED Alarm 1 Abnormal Temperature Alarm 2 Transmission Failure Sensor rotate switch Mute button...

Страница 24: ...eenOK Wireless Thermo Hygro Monitor User s Manual Rev 2 0 24 Tel 82 31 777 5432 Fax 82 31 777 5436 www dadamMicro com 719 Keumkang Hightech Valley 133 1 Sangdaewon1 dong Jungwon gu Sungnam 462 807 Kor...

Отзывы: