![Dacor Wall Ovens Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/dacor/wall-ovens/wall-ovens_installation-instructions-manual_3954646006.webp)
Page 4
Page 5
STEP 4
Electrical Power Supply Requirements
It is the ownerʼs responsibility to ensure that a qualified electrician
performs the electrical connection of this appliance. The electrical
installation, including minimum supply wire size, must comply with
the National Electric Code ANSI/NFPA 70-1990* (or to the latest
revision) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be supplied to
the appliance from a separate, grounded, single phase circuit that is
protected by a properly sized circuit breaker or time-delay fuse. If a
time-delay fuse is utilized, fuse both sides of the line (L1 and L2).
The required voltage, frequency and amperage ratings are listed on
the product data plate (located inside the intake grill to the right of
the door latch) and in Table 3 right.
NOTES:
1. Preheat times and cavity temperature recovery times will be increased slightly if operating on
a 120/208 volt power supply.
2. 208V models should not be connected to 240V source power.
3. Power supply must be an isolated circuit.
WARNING:
If the electrical service provided does not meet the product specifications, do not proceed with the
installation. Call a licensed electrician to correct.
NOTE:
The four (4) leads supplied with this appliance are UL recognized for connection to larger gauge
household wiring. The insulation of these leads is rated at temperatures much higher than the
temperature rating of household wiring. The current-carrying capacity of the conductor is governed
by the temperature rating of the insulation around the wire, rather than the wire gauge alone.
STEP 5
Removing the Oven Door(s)
Due to the weight of this appliance, removing the door(s) will significantly reduce the lifting load, while
also providing the installer with a place to grip the oven when lifting it into place.
Open the door to its fully opened position. Rotate the catch over the retaining arm on each hinge.
Lift the oven door to about a 30˚ angle from the horizontal. Pull the door away from the oven while
continuing to lift.
STEP 6
Turning Off the Power Supply
Before attempting to connect the appliance to power, turn off the electrical
power supply. Also, always turn off electrical power to the appliance prior to
servicing it.
WARNING:
1. Do not attempt to disengage the hinge catches with the door
removed from the oven. The hinge springs could release, causing
personal injury.
2. Do not lift or carry oven door by the door handle.
®
L
L
®
T I
M
E R
1
Hinge Catch
Lift door up to 30˚ angle, then
pull the door away from the oven.
To remove door, rotate
catch up.
30˚
WARNINGS:
Failure to disconnect power may result in
electrical shock or fire hazard.
DACOR
Model number
ECS127
MCS127
ECS130
PCS130
MCS130
ECS136
ECS227
MCS227
ECD227
MCD227
ECS230
PCS230
MCS230
ECD230
PCD230
MCD230
Maximum 208V
connected load
25 Amps
(5.2kW)
34 Amps
(7.0kW)
39 Amps
(8.1kW)
Power supply
208/240V,
4-wire,
60Hz, 30A
208/240V,
4-wire,
60Hz, 40A
Maximum 240V
connected load
22 Amps
(5.2kW)
29 Amps
(7.0kW)
34 Amps
(8.1kW)
Table 3: Electrical Requirements