Dacor RNMD24B Скачать руководство пользователя страница 4

E2

Installation Requirements

The importance of the proper installation of your new 

appliance cannot be overemphasized. Installation should 

be done by a qualified installer.

Before you begin the installation process, read this entire 

installation instruction manual. It contains information 

necessary for proper, safe installation.

Any questions or problems with the installation should 

be directed to your Dacor dealer or the Dacor Customer 

Service Department at 800.793.0093. You can also visit 

our web site at www.Dacor.com.

IMPORTANT NOTES TO THE 

INSTALLER

•  Read all of the installation instructions before 

installing the Microwave In-A-Drawer™.

•  Remove all packing material before connecting 

the electrical supply.

•  Observe all governing codes and ordinances.

•  Be sure to leave these instructions with the 

consumer.

IMPORTANT NOTES TO THE 

CONSUMER

Keep these instructions with your use & care manual for 

future reference.

•  When using any microwave oven generating 

heat, there are certain safety precautions you 

should follow, that are listed in the use & care 

manual. Read the use and care manual and follow 

all safety precautions carefully.

•  Be sure your Microwave In-A-Drawer™ is installed 

and grounded properly by a qualified installer or 

service technician.

For SAFETY CONSIDERATIONS do not install the drawer 

in any combustible cabinetry, which is not in accord with 

the stated clearances and dimensions on pages 3, 4 and 

5. See Figure 2 (for 24") or Figures 4 and 5 (for 30").

GROUNDING INSTRUCTIONS

 WARNING

Improper use of the grounding plug can result in a 

risk of electric shock.

This appliance is equipped with a three-prong grounding 

plug for your protection against possible electric 

shock hazards. It must be plugged into a grounded 

wall receptacle. If only a two-prong wall receptacle 

is available, it is the responsibility of the customer to 

have it replaced with a properly grounded three-prong 

wall receptacle. Do not under any circumstances, 

cut or remove the third (ground) prong from the 

power cord. Do not use an adapter plug. Do not use 

an extension cord. If the power supply cord is too short, 

have a qualified electrician or serviceman install an outlet 

near the appliance. Do not use a Ground Fault Circuit 

Interrupter.

Power supply cord with 

three-prong grounding plug

Grounding type wall receptacle 

(ground fault circuit not allowed)

Содержание RNMD24B

Страница 1: ...nts 4 Anti tip Block 5 Installation Instructions 5 6 Verifying Package Contents 5 Electrical Outlet 5 Drawer Installation 6 Model and Serial Number Location 6 Care Cleaning and Maintenance 6 Before Yo...

Страница 2: ......

Страница 3: ...O KNOW ABOUT SAFETY INSTRUCTIONS Warnings and Important Safety Instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur Always use common sense...

Страница 4: ...use and care manual and follow all safety precautions carefully Be sure your Microwave In A Drawer is installed and grounded properly by a qualified installer or service technician For SAFETY CONSIDE...

Страница 5: ...oven Be sure that the clearance of the floor between the wall oven and the drawer is a minimum of 2 The Microwave In A Drawer interior will easily accommodate a 9 x 13 oblong dish or bag of microwave...

Страница 6: ...minimum overlap L 36 nominal countertop height M Allow 1 8 minimum overlap N Floor must support 100 lbs O 30 cabinet minimum P 15 9 16 opening NOTE Open Top Cabinet illustrated Figure 5 A 84 nominal...

Страница 7: ...s broken or loose drawer guides and dents inside the cavity or on the front side of the drawer If there is any damage do not install or operate the Microwave In A Drawer and contact your dealer or a D...

Страница 8: ...terials in this microwave Refer to the warranty in your use care manual for Dacor s toll free service number and address Please call or write if you have inquiries about your microwave product and or...

Страница 9: ...quettes de s curit 9 Conditions d installation 9 Notes importantes l installateur 9 Notes importantes au client 9 Instructions de mise la terre 9 Caract ristiques techniques 10 11 D gagements et dimen...

Страница 10: ...S CONSIGNES DE S CURIT Les mises en garde et les importantes consignes de s curit apparaissant dans ce manuel ne couvrent pas toutes les conditions et situations possibles Il faut exercer son bon sens...

Страница 11: ...totalit des directives d installation Il contient des renseignements n cessaires pour un bon la s curit de l installation Il faut acheminer les questions ou les probl mes concernant l installation vot...

Страница 12: ...s pla t voir les instructions pour le montage encastr inclus avec le affleurant vent de d flecteur A 6 po 152 40 mm B Emplacement de la prise lectrique C Bloc antibasculement D 5 po 127 mm E 3 1 2 po...

Страница 13: ...5 A Armoire murale 84 po 2133 6 mm nominale B D coupe du four mural optionnel illustr dans le dessin C Emplacement de la prise lectrique D 6 po 152 40 mm E Bloc anti basculement F 3 1 2 po 88 90 mm G...

Страница 14: ...si res du tiroir ne sont pas bris es ou desserr es et que l int rieur de la cavit ou la fa ade ne porte aucune trace de coups En cas de quelque dommage que ce soit ne pas faire fonctionner le four mic...

Страница 15: ...ctueux de ce four Vous trouverez le num ro de service sans frais et l adresse de Dacor dans la garantie dans votre mode d emploi et d entretien Veuillez appeler ou crire si vous avez des questions au...

Страница 16: ...ppliances Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc L informat...

Отзывы: