7
Installation Specifications
Cutout Dimensions
Cooktop with
Downdraft: ERV Series
Countertop Cutout
Dimensions
All tole1/16” -0” (+1.6 mm) unless otherwise noted.
Countertop Cutout View
4 1/4” (10.8 cm) min.
from mounting surface to
combustibles below
cooktop chassis
E
F
C
D
Minimum distance to combustible side
wall above countertop (both sides)
F
Vertical
combustible
surface
Rear
wall
1 5/8” min.
(4.1 cm)
Configuration
(C) Minimum
(D)
(E)
(F) Minimum
RNCT305G with no downdraft
3 1/4” (8.3 cm)
19 5/8” (49.9 cm)
27 5/8” (70.2 cm)
6 7/8” (17.5 cm)
RNCT305G with ERV3015 downdraft
3/8” (1.0 cm)
22 3/4” (57.8 cm)
27 5/8” (70.2 cm)
RNCT365G with no downdraft
3 1/4” (8.3 cm)
19 5/8” (49.9 cm)
33 5/8” (85.4 cm)
RNCT365G with ERV3615 downdraft
3/8” (1.0 cm)
22 3/4” (57.8 cm)
33 5/8” (85.4 cm)
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm)
behind downdraft
to clear stiffener
3/8” min. (1.0 cm)
clearance required
behind cutout
ERVxx15 Downdraft
Check downdraft
dimensions/specifications
to determine proper fit
RNCT Series Cooktop