PLANNING
GUIDE
RNRP30G, RNRP36G, RNRP48G
Renaissance
30”, 36” and 48”
Gas Ranges
Document # PG05-012
Revised 08/21/15 Page 4/4
BACK OF RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure*
(WC)
Min. Gas
Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 psi
LP
10”
11”
1/2 psi
IMPORTANT:
The information above is for reference only. If the above data does not agree with the product data label, use
the data on the product data label on top of the kick plate below the door (see the installation instructions for location).
The range comes from the factory with the regulator installed. Use only the installed regulator. The regulator inlet
accommodates a 3/4” gas line. The range ships with a 1/2” to 3/4” adapter connected to the regulator.
ELECTRICAL REQUIREMENTS
For 30”, 36” and 48” Ranges
Electrical Circuit
Required
Total Connected
Load
120 Vac, 60 Hz, 15 Amp.
Grounded, dedicated, 3- prong
electrical outlet
5.0 Amps. @120 Vac,
60 Hz,
B
A
Electrical and Gas Requirements
Range
Model
A
B
RNRP30G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
4 5/16”
(12.16 cm)
RNRP36G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
7 5/16”
(18.6 cm)
RNRP48G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
4 1/4”
(10.8 cm)