PLANNING

GUIDE

 

All maximum and minimum dimensions and clearances shown 

in the diagrams below must be maintained for safe operation.

 

The range should be placed away from drafts that may be 

caused by doors, windows and heating and air conditioning 

outlets.

 

Avoid cabinet installations directly above the range. If cabinet 

storage is to be provided above the range, the risk can be 

reduced by installing a range hood that projects horizontally a 

minimum of 5 inches beyond the bottom of the cabinets.

 

The range may be installed flush to the rear wall. Dacor 

strongly recommends installing a non-combustible material 

on the rear wall above the range and up to the vent hood or 

installation of a backguard.

 

Any openings in the wall behind the appliance or in the floor 

underneath it must be sealed.

 

The shaded area in the Recommended Cabinet Clearance 

Dimensions figure shows the recommended locations of the 

gas inlet and the electrical junction box. For replacement 

purposes, the location of the existing utilities may be used 

provided they do not interfere with the sides or rear of the 

range. 

 

The junction box and gas shut off valve must be located 

so that the range can be pulled out for service while the 

appliance remains connected.

 

An external, manual shut-off valve must be installed between 

the gas inlet and the range for the purpose of turning on or 

shutting off gas to the appliance.

The installation must allow for the following:

 

Access to the gas shut-off valve when the unit is installed.

 

Access to the remote circuit breaker panel/fuse box, when the 

range is in place.

 

The gas supply piping and shut-off valve, and the electrical 

junction box must be located so they do not interfere with the 

range when it is installed.

Cutout tolerances: +1/16” 0” (1.6 mm) 

unless otherwise stated.

RANGE CUTOUT WITH OPTIONAL 

DOWNDRAFT SPACING

(TOP VIEW)

Cabinet Layout

G

10" (25.4 cm) min.
to combustible side
walls 

above

 the range

(both sides)

non-combustible

rear wall (recommended)

Backsplash

3/8" (1.0 cm)

min. for downdraft cap

clearance

H

J

Note 2
Next page

RNRP30G, RNRP36G, RNRP48G

Renaissance

 

30”, 36” and 48”  

Gas Ranges

Document # PG05-012

Revised 08/21/15    Page 1/4

DIMENSIONS: SEE TABLE ON FOLLOWING PAGE