background image

4

Electrical Specifications

• 

It is the owner’s responsibility to ensure that a licensed 

electrician performs the installation of the electrical sup-

ply for this appliance. The electrical installation, includ-

ing minimum supply wire size, must comply with the 

National Electric Code ANSI/NFPA 70 (latest revision) 

and local codes and ordinances.

A copy of this standard may be obtained from:

• 

The correct voltage, frequency and amperage must be 

supplied to the appliance from a dedicated, grounded, 

single phase circuit that is protected by a properly sized 

circuit breaker or time-delay fuse. If a time-delay fuse is 

utilized, fuse both sides of the line (L1 and L2).

• 

Preheat times and cavity temperature recovery times 

will be increased slightly if operating the unit with less 

than a 240 Vac circuit.

• 

This appliance is provided with electrical wiring in a 

flexible metal conduit.

Product Specifications

Model 

Number

Dedicated Circuit 

Requirements

total Connected 

Load

RO130S

240 Vac 60 Hz,  

4 wire*, 30 Amp.

6.0 kW (25.0 Amp.)

RO130B
ROV130B
RO230S

240 Vac 60 Hz,  

4 wire*, 60 Amp.

12.0 kW (50.0 Amp.)

RO230B
ROV230B

* Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above specifications are for reference only. See the 

appliance data plate (page 3) for exact specifications.

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

Model 

Number

 (A) 

Overall 

Width

(B) Chassis 

Width 

 (C) Overall 

Height

(D) Chassis 

Height

(E) Control 

Panel 

Overlay

RO130S

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

27 5/8” (70.2 

cm)

26 5/8” 

(67.6 cm)

1” 

(2.5 cm)

RO130B
ROV130B
RO230S

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

49 7/8” 

(126.7 cm)

49” 

(124.5 cm)

7/8”  

(2.2 cm)

RO230B
ROV230B

Product Dimensions

All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.

(F) Utility 

Cutout 

Width

(G) Utility 

Cutout 

Height

 (H) Utility 

Cutout 

Depth

 (J) Control 

Panel 

Depth

 (K) Chassis 

Depth

All Models

6 1/4”  

(15.9 cm)

4 3/4” 

(12.1 cm)

7 3/4” 

(19.7 cm)

1 3/16” 

(3.0 cm)

23 5/8”  

(60.0 cm)

Содержание Renaissance RO130

Страница 1: ...Installation Instructions Renaissance Wall Oven RO Model Series Part No 105487 Rev A...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2011 Dacor all rights reserved...

Страница 3: ...neral Safety Precautions 2 Customer Service Information 3 If You Need Help 3 Appliance Data Plate 3 Model Identification 3 Product Specifications 4 Electrical Specifications 4 Product Dimensions 4 Imp...

Страница 4: ...ructed to do so in this manual WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau tions including...

Страница 5: ...less steel side trim panels Equipped with brushed stainless steel millennia style han dles If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor C...

Страница 6: ...a flexible metal conduit Product Specifications Model Number Dedicated Circuit Requirements Total Connected Load RO130S 240 Vac 60 Hz 4 wire 30 Amp 6 0 kW 25 0 Amp RO130B ROV130B RO230S 240 Vac 60 Hz...

Страница 7: ...0 152 cm long D J B H G F Top of chassis Utility cutout K Control panel side view Control panel front Top of chassis E Design Specifications 3 1 2 8 9 cm 3 3 16 8 1 cm 1 1 8 2 9 cm 1 1 8 2 9 cm Produc...

Страница 8: ...n the installation so that all minimum clearances are met or exceeded Dimensions shown provide mini mum clearances unless otherwise noted Be certain that proper clearance is provided for the oven door...

Страница 9: ...9 cm support platform 31 1 4 79 4 cm recommended 1 2 5 cm min to bottom of cabinet door 1 2 5 cm min to top of cabinet door N 1 1 2 3 8 cm typical counter 1 2 5 cm min to combustible floor 3 4 1 9 cm...

Страница 10: ...k oven rack single ovens come with 1 double ovens come with 2 Remove the door s to reduce weight and make the oven easier to lift warning Do not attempt to disengage the hinge catches with the door re...

Страница 11: ...iring of the dedicated supply circuit They are suitable for connection to household wiring under the jurisdiction of the National Electric Code and or the local inspection authority 1 Before proceedin...

Страница 12: ...e metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a minimum 4 AWG wire to establish continuity to ground See faci...

Страница 13: ...External Ground Conduit to oven Incoming power Wire nut 4 places Junction box Separate 10 AWG wire minimum Clamp wire tightly to pipe RED RED WHITE WHITE GREEN GREEN BLACK BLACK Clamps Bare metal Ins...

Страница 14: ...ting platform slide the oven into the recessed area until the rear edge of the oven frame is flush with the cabinet face and the oven is centered within the cut out Ensure that the electrical conduit...

Страница 15: ...lastic that covers the stainless steel surfaces 2 Remove any packaging from inside the oven s 3 Slide the oven racks onto the supports inside the oven chamber s according to the use and care manual 4...

Страница 16: ...grounded according to these instructions and in accordance with all applicable elec trical codes See pages 4 and 9 Is the oven secured into the cabinet with all the mount ing screws four 4 on single...

Страница 17: ...15 Notes...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: