Dacor Renaissance RNWO230 Скачать руководство пользователя страница 12

10

Installation Instructions

Electrical Connection - (continued)

Connecting to a Three Wire Electrical 

System - Where Local Codes Permit

 WARNING

Do not connect the green appliance conduit wire to the 

neutral (white) junction box wire unless local building 

codes permit.

1. Separate the wires coming out of the appliance conduit.
2. Connect the green and white wires from the appliance

conduit to the white (neutral) supply wire in the junction

box.

3. Connect the black wire from the appliance conduit to

the black (L1) supply wire in the junction box.

4. Connect the red wire from the appliance conduit to the

red (L2) supply wire in the junction box.

Connecting to a Three Wire Electrical 

System with External Ground - Where Local 

Codes Permit

 WARNING

• Do not ground the appliance to a gas supply pipe or

hot water pipe.

• If connecting the ground wire to a grounded cold water

pipe, connect using a separate copper grounding

wire (No. 10 minimum) and a clamp with an external

grounding screw. The grounded cold water pipe must

have metal continuity to electrical ground and must not

be interrupted by insulating materials. Any insulating

materials must be jumped, with a minimum, 4 AWG

wire to establish continuity to ground. See facing page.

 NOTE

If the junction box has been properly grounded by a 

licensed electrician, the green (ground) wire from the 

appliance conduit may be connected to the junction box 

using a loop terminal.

To connect the green appliance conduit wire to a 

grounded cold water pipe, see diagrams on facing 

page.

1. Separate the wires coming out of the appliance conduit.
2. Connect the white wire from the appliance conduit to

the white (neutral) supply wire in the junction box.

3. Connect the black wire from the appliance conduit to

the black (L1) supply wire in the junction box.

4. Connect the red wire from the appliance conduit to the

red (L2) supply wire in the junction box.

5. Connect the green wire from the appliance conduit to a

grounded cold water pipe as shown. Jumper any insu-

lating materials as shown above with a length of No. 4

copper wire. Securely clamp the wire to bare metal at

both ends.

Incoming power

Wire nut,

3 places

Junction box

Conduit to 

oven

Three Wire Connection

RED
RED

WHITE

WHITE

GREEN

BLACK
BLACK

Содержание Renaissance RNWO230

Страница 1: ...Installation Instructions Renaissance Wall Oven Models RNWO130 RNWO230 RNWOV130 and RNWOV230 Fran ais Voir page 21...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2011 Dacor all rights reserved...

Страница 3: ...neral Safety Precautions 2 Customer Service Information 3 If You Need Help 3 Appliance Data Plate 3 Model Identification 3 Product Specifications 4 Electrical Specifications 4 Product Dimensions 4 Imp...

Страница 4: ...the oven unless specifically instructed to do so in this manual WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow ba...

Страница 5: ...site www dacor com Dacor Distinctive Service repairs under warranty only Phone 800 793 0093 ex 2822 U S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Product Data Label The product dat...

Страница 6: ...al wiring in a flexible metal conduit Product Specifications Model Number Total Connected Load Dedicated Circuit Requirements RNWO V 130 240 Vac 60 Hz 24 5 Amp 6 0 kW 240 Vac 60 Hz 4 wire 30 Amp RNWO...

Страница 7: ...J B H G F Top of chassis Utility cutout K Control panel side view Control panel front Top of chassis E Design Specifications 3 1 2 8 9 cm 3 3 16 8 1 cm 1 1 8 2 9 cm 1 1 8 2 9 cm 1 1 8 2 9 cm Product...

Страница 8: ...isconnected Plan the installation so that all minimum clearances are met or exceeded Dimensions shown provide mini mum clearances unless otherwise noted Be certain that proper clearance is provided fo...

Страница 9: ...1 9 cm support platform 31 1 4 79 4 cm recommended 1 2 5 cm min to bottom of cabinet door 1 2 5 cm min to top of cabinet door N 1 1 2 3 8 cm typical counter 1 2 5 cm min to combustible floor 3 4 1 9 c...

Страница 10: ...oven rack single ovens come with 1 double ovens come with 2 Remove the door s to reduce weight and make the oven easier to lift WARNING Do not attempt to disengage the hinge catches with the door remo...

Страница 11: ...d household wiring of the dedicated supply circuit They are suitable for connection to household wiring under the jurisdiction of the National Electric Code and or the local inspection authority 1 Bef...

Страница 12: ...e metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a minimum 4 AWG wire to establish continuity to ground See faci...

Страница 13: ...External Ground Conduit to oven Incoming power Wire nut 4 places Junction box Separate 10 AWG wire minimum Clamp wire tightly to pipe RED RED WHITE WHITE GREEN GREEN BLACK BLACK Clamps Bare metal Ins...

Страница 14: ...t mounting platform slide the oven into the recessed area until the rear edge of the oven frame is flush with the cabinet face and the oven is centered within the cutout Ensure that the electrical con...

Страница 15: ...n bottom of hinge Lower lip of hinge receptacle Verifying Proper Operation 1 For stainless steel ovens peel off the protective layer of plastic that covers the stainless steel surfaces 2 Remove any pa...

Страница 16: ...ed and grounded according to these instructions and in accordance with all applicable elec trical codes See pages 4 and 9 Is the oven secured into the cabinet with all the mount ing screws four 4 on s...

Страница 17: ...Instructions d installation Four mural Mod les RO130 RO230 ROV130 and ROV230...

Страница 18: ...s sp cifications figurant dans ce manuel sont susceptibles d tre modifi es sans pr avis Dacor n assumera aucune responsabilit en cas de modification de ces sp cifications 2014 Dacor tous droits reserv...

Страница 19: ...oximite de cet appareil ou de tout autre appareil electromenager Garder les articles qui pourraient exploser comme les g n ra teurs d a rosol loign s des appareils m nagers Ne pas entreposer de produi...

Страница 20: ...rs l avant de l appareil fixer l appareil l armoire l aide des vis de montage fournies ADVERTISSEMENT Mesures de s curit g n rales Pour r duire le risque d incendie de choc lectrique de blessures ou d...

Страница 21: ...nom du mod le et le num ro de s rie de l appareil Le mod le et le num ro de s rie sont imprim s sur l tiquette de donn es sur le produit quipe de service la client le Dacor T l phone 800 793 0093 ex...

Страница 22: ...plus longs si l appareil fonctionne avec un circuit de moins de 240 VCA Cet appareil m nager est fourni avec du c blage lectrique dans un conduit en m tal flexible Prescriptions d installation Mod le...

Страница 23: ...and E Haut du ch ssis Vue lat rale Longueur du conduit d alimentation 60 152 cm Haut du ch ssis L entaille pour les services Prescriptions d installation Dimensions du produit Toutes les tol rances 1...

Страница 24: ...anch Planifier l installation afin de respecter ou d passer tous les d gagements minimums Les dimensions indiqu es offrent les d gagements minimums sauf indication contraire S assurer de tenir compte...

Страница 25: ...trique recommand Emplacement lectrique de remplacement 1 1 2 3 8 cm comptoir type 1 2 5 cm min au plancher combustible 1 2 5 cm min aux combustibles Emplacement lectrique recommand 4 coup de pied type...

Страница 26: ...ur GlideRack MC 1 pour four simple 2 pour four double Enl vement de la porte Enlever la porte pour faciliter le d placement de la four pen dant le processus d installation ADVERTISSEMENT Ne pas tenter...

Страница 27: ...un calibre plus petit que le c blage standard du domicile de la conduite d alimentation r serv e Ils r pondent aux exigences du raccordement au c blage du domicile selon les attributions du National E...

Страница 28: ...eau chaude Au raccordement du fil de mise la terre un tuyau d eau froide mis la terre raccorder l aide d un fil de mise la terre s par en cuivre no 10 minimum et une bride avec une vis de mise la ter...

Страница 29: ...cteurs depuis le four Conduit depuis le point de distribution du domicile Connecteurs de fils 4 Bo tier de jonction Fil de 10 AWG minimum s par Fixer le fil solidement au tuyau Brides de serrage m tal...

Страница 30: ...u four soit gal au devant de l armoire et que le four est centr dans l entaille S assurer que la con duit lectrique passe par l ouverture dans la plateforme de l armoire ou les serpentins au dessus du...

Страница 31: ...ur du four 3 Glisser les grilles du four sur les supports l int rieur des chambres de cuisson selon le manuel d utilisation 4 Alimenter l appareil au niveau du disjoncteur ou du coffret de fusibles 5...

Страница 32: ...up port solide et horizontale Voir page 22 L appareil m nager est il c bl et mis la terre selon ces instructions et conform ment tous les codes lectriques en vigueur Les raccordements sont ils serr s...

Страница 33: ...31 Notes...

Страница 34: ...32 Notes...

Страница 35: ......

Страница 36: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com Part No 105487 Rev J...

Отзывы: