Dacor Renaissance RNTT365GB Скачать руководство пользователя страница 3

All specifications subject to change without notice.

Phone: (800) 793-0093

www.dacor.com

PLANNING

GUIDE

4.40

RNTT365GB

Renaissance 36” Wide

Drop-in,Touch-Control Gas Cooktop

Document # PG04-010

Revised 09/02/15   Page 3/5

Cabinet and Countertop Layout

 WARNING

•  To reduce the risk of personal injury caused by reaching 

over a hot appliance, avoid locating cabinet storage 

space directly above the cooktop.

•  Failure to meet or exceed the maximum and minimum 

dimensions/clearances stated in these instructions may 

result in a fire hazard.

•  Follow the countertop manufacturer’s instructions 

regarding the minimum corner radius, use of heat 

reflective tape, reinforcement of corners, etc.

◊ 

Carefully check the location where the cooktop will be 

installed. For best performance, the cooktop should be placed 

away from drafts that may be caused by doors, windows, and 

heating and air conditioning outlets. 

◊ 

This appliance must be installed in a well ventilated room. To 

reduce the risk of personal injury and to reduce accumulated 

smoke in the room, Dacor strongly recommends installing 

a range hood. A range hood should project horizontally a 

minimum of five (5) inches beyond the face of the cabinets.

To allow clearance for hold-down brackets:

◊ 

The gas supply piping, gas shut-off valve, and the electrical 

outlet must be positioned so they do not interfere with the 

cooktop when it is installed.

◊ 

If installing another appliance in the cabinet below, allow for 

the routing of gas and electrical service behind it.

The installation must have these access and clearance 

allowances:

◊ 

Access to the gas shut-off valve and regulator after the unit is 

installed. 

◊ 

Access to the electrical outlet when the cooktop is in place. 

The 72-inch (183 cm) power cord must be able to directly 

reach the electrical outlet.

◊ 

Clearance inside the cabinet to allow for proper hold- down 

bracket installation.

All tole1/16” -0” (unless otherwise noted).

Minimum Overhead Clearances

13" max.

3

(33.0 cm)

3

 Not applicable for cabinets more than a horizontal distance of  

  

 

1 1/8” (2.9 cm) from edge of cooktop. Allow 2 7/8” (7.3 cm) 

  

 

from cutout edge.

 

  15" min.

1, 3

(38 cm)

Combustible 

surface to rear

Combustible overhead 

cabinets

25" min.

1, 2

(63.5 cm)

36" min.

4

(91.4 cm)

See cutout

dimensions

2

 If installing with an overhead vent hood, also check the hood 

  

 

specifications for minimum required clearances.

1

 Measured from the cooking surface (top of cooktop grate).

4

 42” (106.7 cm) recommeded.