4

Electrical Specifications

•  It is the owner’s responsibility to ensure that a licensed 

electrician performs the installation of the electrical sup-

ply for this appliance. The electrical installation, includ-

ing minimum supply wire size, must comply with the 

National Electric Code ANSI/NFPA 70 (latest revision) 

and local codes and ordinances.

    A copy of this standard may be obtained from:

•  The correct voltage, frequency and amperage must be 

supplied to the appliance from a dedicated, grounded, 

single phase circuit that is protected by a properly sized 

circuit breaker or time-delay fuse. If a time-delay fuse is 

utilized, fuse both sides of the line (L1 and L2).

•  Preheat times and cavity temperature recovery times 

will be increased slightly if operating the unit with less 

than a 240 Vac circuit.

•  This appliance is provided with electrical wiring in a 

flexible metal conduit.

Product Specifications

Model 

Number

Total Connected 

Load*

Dedicated Circuit 

Requirements

RNO(V)127

240 Vac 60 Hz,  

19.0 Amp., 4.7 kW

240 Vac 60 Hz,  

4 wire**, 30 Amp.

RNO(V)130

240 Vac 60 Hz,  

24.5 Amp., 6.0 kW

240 Vac 60 Hz,  

4 wire**, 30 Amp.

RNO(V)227

240 Vac 60 Hz,  

39.4 Amp., 9.5 kW

240 Vac 60 Hz,  

4 wire**, 40 Amp.

RNO(V)230

240 Vac 60 Hz,  

48.6 Amp., 12.0 kW

240 Vac 60 Hz,  

4 wire**, 50 Amp.

* This specification is for reference only. See the product 

data label (see page 3) for exact specifications.
** Two 120 Vac hot (L1 and L2), one neutral, one ground.

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

Product Dimensions

All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.

(F) Utility 

Cutout 

Width

(G) Utility 

Cutout 

Height

 (H) Utility 

Cutout 

Depth

 (J) Control 

Panel 

Depth

 (K) Chassis 

Depth

 (L) Control 

Panel Notch 

Depth

 (M) Control 

Panel Notch 

Height

All Models

6 1/2” 

(16.5 cm)

5” 

(12.7 cm)

7 7/8” 

(20.0 cm)

3/4” 

(1.9 cm)

24”  

(61.0 cm)

1/2” 

(1.3 cm)

3/4”  

(1.9 cm)

Model 

Number

 (A) 

Overall 

Width

(B) Chassis 

Width 

 (C) Overall 

Height

(D) Chassis 

Height

(E) Control 

Panel 

Overlay

RNO(V)127

26 7/8”  

(68.3 cm)

25 3/8”  

(64.5 cm)

27 3/4”

(70.5 cm)

27 3/8”

(69.5 cm)

3/8” 

(1.0 cm)

RNO(V)130

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

27 3/4”

(70.5 cm)

27 3/8”

(69.5 cm)

3/8” 

(1.0 cm)

RNO(V)227

26 7/8”  

(68.3 cm)

25 3/8”  

(64.5 cm)

50 1/8”

(127.3 cm)

49 3/4”

(126.4 cm)

3/8” 

(1.0 cm)

RNO(V)230

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

50 1/8”

(127.3 cm)

49 3/4”

(126.4 cm)

3/8” 

(1.0 cm)

Содержание Renaissance RNO130

Страница 1: ...Installation Instructions Renaissance Wall Oven Models RNO127 RNO130 RNO227 RNO230 RNOV127 RNOV130 RNOV227 RNOV230 Fran ais Voir page 15...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2014 Dacor all rights reserved...

Страница 3: ...al Safety Precautions 2 Customer Service Information 3 If You Need Help 3 Product Data Label 3 Model Identification 3 Product Specifications 4 Electrical Specifications 4 Product Dimensions 4 Importan...

Страница 4: ...orward secure the oven to the cabinet using the supplied mounting screws WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance...

Страница 5: ...te www dacor com Dacor Distinctive Service repairs under warranty only Phone 800 793 0093 ex 2822 U S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Product Data Label The product data l...

Страница 6: ...30 Amp RNO V 130 240 Vac 60 Hz 24 5 Amp 6 0 kW 240 Vac 60 Hz 4 wire 30 Amp RNO V 227 240 Vac 60 Hz 39 4 Amp 9 5 kW 240 Vac 60 Hz 4 wire 40 Amp RNO V 230 240 Vac 60 Hz 48 6 Amp 12 0 kW 240 Vac 60 Hz 4...

Страница 7: ...60 152 cm long Control panel side view Control panel front Top of chassis Top of chassis Utility cutout C A D J H K E L M B G F Design Specifications 2 3 8 6 0 cm 1 7 8 4 8 cm Product Dimensions All t...

Страница 8: ...clearances unless otherwise noted Be certain that proper clearance is provided for the oven door when it is in the open position according to the Product Dimensions Cabinet cutout dimensions must be u...

Страница 9: ...t platform 31 1 4 79 4 cm recommended 1 2 5 cm min to bottom of cabinet door 1 2 5 cm min to top of cabinet door N 1 1 2 3 8 cm typical counter 1 2 5 cm min to combustible floor 3 4 1 9 cm support pla...

Страница 10: ...2 GlideRack oven rack single ovens come with 2 double ovens come with 4 Remove the door s to reduce weight and make the oven easier to lift WARNING Do not attempt to disengage the hinge catches with...

Страница 11: ...ousehold wiring of the dedicated supply circuit They are suitable for connection to household wiring under the jurisdiction of the National Electric Code and or the local inspection authority 1 Before...

Страница 12: ...ernal grounding screw The grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a mi...

Страница 13: ...External Ground Conduit to oven Incoming power Wire nut 4 places Junction box Separate 10 AWG wire minimum Clamp wire tightly to pipe RED RED WHITE WHITE GREEN GREEN BLACK BLACK Clamps Bare metal Ins...

Страница 14: ...t mounting platform slide the oven into the recessed area until the rear edge of the oven frame is flush with the cabinet face and the oven is centered within the cutout Ensure that the electrical con...

Страница 15: ...n bottom of hinge Lower lip of hinge receptacle Verifying Proper Operation 1 For stainless steel ovens peel off the protective layer of plastic that covers the stainless steel surfaces 2 Remove any pa...

Страница 16: ...ed and grounded according to these instructions and in accordance with all applicable elec trical codes See pages 4 and 9 Is the oven secured into the cabinet with all the mount ing screws four 4 on s...

Страница 17: ...Instructions d installation Four mural Mod les RNO127 RNO130 RNO227 RNO230 RNOV127 RNOV130 RNOV227 RNOV230...

Страница 18: ...s sp cifications figurant dans ce manuel sont susceptibles d tre modifi es sans pr avis Dacor n assumera aucune responsabilit en cas de modification de ces sp cifications 2014 Dacor tous droits reserv...

Страница 19: ...e de cet appareil ou de tout autre appareil electromenager Garder les articles qui pourraient exploser comme les g n ra teurs d a rosol loign s des appareils m nagers Ne pas entreposer de produits inf...

Страница 20: ...l armoire l aide des vis de montage fournies ADVERTISSEMENT Mesures de s curit g n rales Pour r duire le risque d incendie de choc lectrique de blessures ou de dommages lors de l utilisation de cet a...

Страница 21: ...uer le nom du mod le et le num ro de s rie de l appareil Le mod le et le num ro de s rie sont imprim s sur l tiquette de donn es sur le produit quipe de service la client le Dacor T l phone 800 793 00...

Страница 22: ...lexible Prescriptions d installation Mod le Charge branch e totale Exigences circuit r serv RNO V 127 240 VCA 60 Hz 19 0 Amp 4 7 kW 240 VCA 60 Hz 4 fil 30 A RNO V 130 240 VCA 60 Hz 24 5 Amp 6 0 kW 240...

Страница 23: ...mmand Haut du ch ssis Vue lat rale Longueur du conduit d alimentation 60 152 cm Haut du ch ssis L entaille pour les services C A D J H K E L M B G F Prescriptions d installation 2 3 8 6 0 cm 1 7 8 4 8...

Страница 24: ...s offrent les d gagements minimums sauf indication contraire S assurer de tenir compte du d gagement appropri pour la porte du four lorsqu elle est ouverte selon les Dimensions du produit La profondeu...

Страница 25: ...me de support Emplacement lectrique recommand Emplacement lectrique de remplacement 1 1 2 3 8 cm comptoir type 1 2 5 cm min au plancher combustible 1 2 5 cm min aux combustibles Emplacement lectrique...

Страница 26: ...ur GlideRack MC 2 pour four simple 4 pour four double Enl vement de la porte Enlever la porte pour faciliter le d placement de la four pen dant le processus d installation ADVERTISSEMENT Ne pas tenter...

Страница 27: ...un calibre plus petit que le c blage standard du domicile de la conduite d alimentation r serv e Ils r pondent aux exigences du raccordement au c blage du domicile selon les attributions du National E...

Страница 28: ...eau chaude Au raccordement du fil de mise la terre un tuyau d eau froide mis la terre raccorder l aide d un fil de mise la terre s par en cuivre no 10 minimum et une bride avec une vis de mise la ter...

Страница 29: ...cteurs depuis le four Conduit depuis le point de distribution du domicile Connecteurs de fils 4 Bo tier de jonction Fil de 10 AWG minimum s par Fixer le fil solidement au tuyau Brides de serrage m tal...

Страница 30: ...u four soit gal au devant de l armoire et que le four est centr dans l entaille S assurer que la con duit lectrique passe par l ouverture dans la plateforme de l armoire ou les serpentins au dessus du...

Страница 31: ...ur du four 3 Glisser les grilles du four sur les supports l int rieur des chambres de cuisson selon le manuel d utilisation 4 Alimenter l appareil au niveau du disjoncteur ou du coffret de fusibles 5...

Страница 32: ...up port solide et horizontale Voir page 22 L appareil m nager est il c bl et mis la terre selon ces instructions et conform ment tous les codes lectriques en vigueur Les raccordements sont ils serr s...

Страница 33: ...31 Notes...

Страница 34: ...32 Notes...

Страница 35: ......

Страница 36: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com Part No 107938 Rev B...

Отзывы: