background image

31

PMOR3021S
PMOR3021B
PMOR3021R

4. Remove the three (3) screws holding the hood louver to

the oven cavity front face plate.

5. Pull the hood louver from the oven cavity by pushing the

right and left tabs of the hood louver to remove.

6. Now, the hood louver is free.

REMOVAL OF OVEN FROM WALL (Two persons recommended to remove the oven)

1. Disconnect the power supply cord, and uncoil the power

supply cord.

2. To discharge the high voltage capacitor, wait for 60 seconds.
3. If the exhaust damper assembly is installed, remove the

one (1) screw holding the exhaust  damper assembly to
the rear stay, and remove the exhaust  damper assembly
by sliding it backward.

4. Remove the two (2) screws holding the oven (outer case

cabinet) to the top cabinet.

5. While supporting the front of the oven, pull down the two

(2) mounting levers and release the oven from the unit
mounting plate.

6. Pull the power cord out of the wall cabinet and remove

the oven.

7. The oven is now free and can be placed on the work

surface selected for servicing the oven.

8. Installation is the reverse of this procedure.

OUTER CASE REMOVAL

Remove the oven from the wall, referring to "REMOVAL OF
OVEN FROM WALL" and proceed as follows;
1. Disconnect the power supply cord.
2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Remove five (5) screws holding the rear stay to the outer

case cabinet, hood fan motor or the oven, and remove it.

5. Remove the six (6) screws from the rear of the outer case

cabinet and one (1) screw at front.

6. Slide the outer case cabinet back about 1 inch (3 cm) to

free it from retaining clips on the cavity face plate.

7. Disconnect the three (3) pin connector of the power

supply cord from the wiring harness and remove the

power supply cord together with the outer case.

8. Nip the cord bushing with bushing pliers and release it

from the outer case cabinet.

9. Remove the cord bushing and the power supply cord

from the outer case cabinet.

10.Now, the power supply cord or the outer case cabinet is

free.

CAUTION: 1. DISCONNECT OVEN FROM POWER

SUPPLY BEFORE REMOVING OUTER
CASE.

2. DISCHARGE THE HIGH VOLTAGE

CAPACITOR BEFORE TOUCHING ANY
OVEN COMPONENTS OR WIRING.

Left tab

Screws

Right tab

Hood louver

1. Disconnect the power supply cord and remove the oven

from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")

2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Disconnect the 6-pin connector of the hood fan motor

HOOD FAN MOTOR REMOVAL

from the main wire harness located at the right edge of
the oven cavity top plate and release the snap band from
the hood duct.

5. Remove the hood fan motor  from the oven cavity top

plate by lifting it up.

6. Now, the hood fan motor is free.

1. Disconnect the power supply cord , remove the oven

from wall and remove outer case (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal".)

2. Open the door and block it open.
3. To discharge the high voltage capacitor, wait for 60 seconds.
4. Remove the seven (7) screws holding the hood intake

duct R to the oven cavity top plate, the oven cavity front
flange, the fan duct and magnetron duct. And remove the
hood intake duct R.

5. Disconnect  the high voltage wire from the magnetron.
6. Release the two (2) tabs of the fan duct from the base plate R.
7. Remove the magnetron duct from the oven cavity, by

releasing the tab of the magnetron duct from the base

MAGNETRON REMOVAL

plate R.

8. Remove the grease filter (right side one) from the base cover.
9. Carefully remove four (4) mounting screws holding the

magnetron to waveguide. When removing the screws
hold the magnetron to prevent it from falling.

10.Remove the magnetron from the unit with care so the

magnetron tube should not be hit by any metal object
around the tube.

CAUTION: WHEN REPLACING THE MAGNETRON, BE

SURE THE R.F. GASKET IS IN PLACE AND
MOUNTING SCREWS ARE TIGHTENED SE-
CURELY.

Содержание PMOR3021B

Страница 1: ...ORMATION 5 OPERATION 7 TROUBLESHOOTING GUIDE 11 TEST PROCEDURE 13 TOUCH CONTROL PANEL ASSEMBLY 23 COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE 30 PICTORIAL DIAGRAM 39 POWER UNIT CIRCUIT 40 LSI UNIT CIRCUIT 41 PRINTED WIRING BOARD 42 PARTS LIST 43 PACKING AND ACCESSORIES 48 In the interest of user safety the oven should be restored to its original condition and only parts identical to those speci...

Страница 2: ...ive unit perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual If microwave emissions level is in excess of the specified limit contact DACOR immediately 1 800 793 0093 If the unit operates with the door open service person should 1 tell the user not to operate the oven and 2 contact DACOR and Food and Drug Administration s Center for Devices...

Страница 3: ... Todischargehighvoltagecapacitor waitfor60seconds 4 Disconnect the leads to the primary of the inverter unit 5 Ensure that these leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 To...

Страница 4: ...astic The placing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set the cooking control on Full Power Cooking Mode 5 Close the door and select a cook cycle of several minutes If the water begins to boil before the survey is completed replace it with 275 ml of cool water C Leakage test Closed door leakage tes...

Страница 5: ...he oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing Service personnel Do not contact the following parts while the appliance is energized Inverter unit that includes High Voltage Capacitor High Voltage Power Transformer High Voltage Rectifier ...

Страница 6: ...ughout the cooking time P 90 approx 90 of Full Power P 80 approx 80 of Full Power P 70 approx 70 of Full Power P 60 approx 60 of Full Power P 50 approx 50 of Full Power P 40 approx 40 of Full Power P 30 approx 30 of Full Power P 20 approx 20 of Full Power P 10 approx 10 of Full Power P 0 No power throughout the cooking time SENSOR CENTER pads MEAL TIME pads HELP GUIDE pad KEEP WARM PLUS pad EASY D...

Страница 7: ... prong grounding plug DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG The power supply cord and plug must be connected to a separate 120 Volt AC 60 Hz 15 Amp or more dedicated line using agroundedreceptacle ThereceptacleshouldbelocatedinsidethecabinetdirectlyabovetheMicrowaveOven Hoodsystem mounting location OVEN DIAGRAM 1 Oven door with see through window 2 Door hinge...

Страница 8: ...OTE Some one touch cooking features such as MINUTE PLUS are disabled after three minutes when the oven is not in use These features are automatically enabled when the door is opened and closed or the STOP CLEAR pad is pressed PMOR3021S ...

Страница 9: ...hen the door was opened 7 Themonitorswitchiselectricallymonitoringtheoperation of the secondary interlock switch and primary interlock switch and is mechanically associated with the door so that it will function in the following sequence 1 When the door opens from a closed position the primary interlock switch and secondary interlock switch open their contacts and then the monitor switch contacts ...

Страница 10: ...Y 2 is energized The power transformer is turned on microwave energy is produced and first stage is started The 32 seconds is the cooling time required to remove any vapor from the oven cavity and sensor NOTE During this first stage do not open the door or touch STOP CLEAR pad 4 When the sensor detects the vapor emitted from the food the display switches over to the remaining cooking time and the ...

Страница 11: ... H1 H3 NOTES 1 Circuits Wire Colors subject to change without notice 2 Terminal that located to the right side on the lamp socket s back view must be connected to neutral wire 3 Only certain models use the absolute humidity sensor H N GND GRN LVT C1 C2 C4 C3 WHT BLU RED BLK BLU WHT RED BLK RED RED FUSE 20A RED ORG RED RED A5 RY3 A7 High BLK BLK WHT HOOD CAPACITOR HOOD MOTOR GRY YLW BLU YLW RED RY4...

Страница 12: ...guide HOOD LAMP The hood lamps are mounted at the hood lamp angle The hood lamps can be turned off and on by touching the Light Options pad And also the brightness can be varied to high or low by touching the Light Options pad DOOR OPEN MECHANISM The door is opened by pushing the open button on the control panel refer to the Figure D 1 Whentheopenbuttonispushed theopenbuttonpushesup the open lever...

Страница 13: ...MPORTANT Whenever troubleshooting is performed with the power supply cord disconnected It may in some cases be necessary to connect the power supply cord after the outer case has been removed in this event 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 To discharge high voltage capacitor waite for 60 seconds 4 Disconnect the leads to the primary o...

Страница 14: ...n cook cycle But it does light when door is opened Fan motor does not operate Oven lamp and strrer motor operate Oven does not go into cook cycle when START pad is touched Oven seems to be operating but little or no heat is produced in oven load Food incompletely cooked or not cooked at all at end of cook cycle Oven goes into a cook cycle but extremely uneven heating is produced in oven load food ...

Страница 15: ...ometerorthermocouplethroughthewater until the temperature stabilizes Record the temperature of the water 2 Place the cup of water in the oven Operate oven at POWER 10 HIGH selecting more than 60 seconds cook time Allow the water to heat for 60 seconds measuring with a stop watch second hand of a watch or the digital read out countdown 3 Remove the cup from the oven and again measure the temperatur...

Страница 16: ...ower output cooking Magnetron is defective Exchange the magnetron Exchange the Inverter unit Brown monitor fuse The secondary interlock switch primary interlock switch and the monitor switch are operating properly YES Exchange the Inverter unit TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST NO Check the switches according to the switch Test Procedure YES NO 1 Disconnect the power supply cord and ...

Страница 17: ...ushed in the meter should indicate an open circuit If improper operation is indicated the switch may be defective After testing the monitor switch reconnect the wire lead to the monitor switch COM terminal and check the continuity of the monitor circuit 5 Reconnect all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer ...

Страница 18: ... all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8 Run the oven and check all functions Resistance between BLU 1 AND YLW 4 0 Ω Shorted BLK 2 AND YLW 4 32 Ω BLU 1 AND BLK 2 32 Ω BLK 2 AND WHT 3 10 Ω WHT 3 AND RED 5 20 Ω 32 Ω 10 Ω 20 Ω HOOD FAN CAPACITOR YLW RED BLU BLK 1 2 3 WHT 4 5 1 2 3 4 5 BLU...

Страница 19: ...certain digit all or some segments do not light up b At a certain digit brightness is low c Only one indicator does not light d The corresponding segments of all digits do not light up or they continue to light up e Wrong figure appears f A certain group of indicators do not light up g The figure of all digits flicker 2 3 Other possible problems caused by defective control unit a Buzzer does not s...

Страница 20: ... C voltmeter The meter should indicate 120 volts if not check oven circuit RY1 RY3 RY4 RY5 and RY6 Relay Test These relays are operated by D C voltage Check voltage at the relay coil with a D C voltmeter during the microwave cooking operation DC voltage indicated Defective relay DC voltage not indicated Check diode which is connected to the relay coil If diode is good control unit is defective REL...

Страница 21: ...mately 160Ω 10 If any abnormal condition is detected replace the control unit 7 Reconnectallleadsremovedfromcomponents during testing 8 Re install the control unit to the control panel and re install the control panel to the oven 9 Reconnect the power supply cord 10 Run the oven and check all functions 2 Follow the troubleshooting guide given below if indicator does not light up after above check ...

Страница 22: ...the food ERROR will appear and the oven will shut off Water load cooking test WARNING The oven should be fully assembled before following procedure Make sure the oven has been plugged in at least two minutes before checking sensor cook operation The cabinet should be installed and screws tightened 1 Fill approximately 200 milliliters 7 2 oz of tap water in a 1000 milliliter measuring cup 2 Place t...

Страница 23: ...en chassis by using insulation tape 8 After that procedure re connect the power supply cord 9 Check the sensor cook operation proceed as follows 9 1 Touch the TIMER CLOCK pad once the POWER LEVEL pad twice the START pad once and the number pad 1 once and the number pad 4 once 9 2 The control panel is in the sensor cooking operation 9 3 After approximately 65 seconds push plunger of select switch f...

Страница 24: ...ICATION OF OHM METER Between source and source Open Circuit Between terminal source and load Short Circuit Between terminal source and load Short Circuit If incorrect readings are obtained replace the noise filter 6 Reconnect all leads removed from components during testing 7 Re install the outer case cabinet 8 Reconnect the power supply cord after the outer case is installed 9 Run the oven and ch...

Страница 25: ... Inverter Unit Control Circuit This is the circuit to control inverter unit The touch control section consists of the following units as shown in the touch control panel circuit 1 Key Unit 2 Control Unit The Control unit consists of LSI Unit and Power U nit The principal functions of these units and the signals communicated among them are explained below Key Unit The key unit is composed of a matr...

Страница 26: ... connected to the A D converter built into the LSI for R 2120J 11 P57 OUT Oven lamp fan motor stirrer motor and inverter unit driving signal To turn on and off shut off relay RY1 The square waveform voltage is delivered to the RY1 driving circuit 12 P56 OUT Signal to sound buzzer 2 0 kHz A key touch sound B Completion sound 13 P50 OUT Terminal not used 14 18 P54 P50 OUT Used for initial balancing ...

Страница 27: ...ignalappliedtotouch keysection ApulsesignalisinputtoP43 P46terminalwhileone of G8 line keys on key matrix is touched 37 P23 OUT Key strobe signal Signalappliedtotouch keysection ApulsesignalisinputtoP43 P46terminalwhileone of G9 line keys on key matrix is touched 38 P22 OUT Key strobe signal Signalappliedtotouch keysection ApulsesignalisinputtoP43 P46terminalwhileone of G10 line keys on key matrix...

Страница 28: ...4 SEG 6 66 SEG 6 11 SEG 18 54 SEG18 23 SEG 5 67 SEG 5 10 SEG 17 55 SEG17 22 SEG 4 68 SEG 4 9 SEG 16 56 SEG16 21 SEG 3 69 SEG 3 8 SEG 15 57 SEG15 20 SEG 2 70 SEG 2 7 SEG 14 58 SEG14 19 SEG 1 71 SEG 1 6 SEG 13 59 SEG13 18 SEG 0 72 SEG 0 5 SEG 12 60 SEG12 17 73 74 VCC VREF IN Connected to GND 75 AVSS IN Connected to VC 76 COM3 OUT Common data signal Connected to LCD signal COM4 77 COM2 OUT Common dat...

Страница 29: ...tration One thermistor is housed in the closed vesselfilledwithdryairwhileanotherintheopenvessel Each sensor is provided with the protective cover made of metal mesh to be protected from the external airflow 2 Operational Principle of Humidity Sensor The figure below shows the basic structure of a humidity sensor A bridge circuit is formed by two thermistors and two resistors R1 and R2 The output ...

Страница 30: ... itself is so short that the two can t be separated For those models check and repair all the controls sensor related ones included of the touch control panel while keeping it connected to the oven B On some models the power supply cord between the touch control panel and the oven proper is long enough that they may be separated from each other For those models it is possible to check and repair t...

Страница 31: ...y solder it is recommend that a dedicated bit is used and that the iron temperature is adjusted accordingly 3 Soldering As the melting point of lead free solder Sn Ag Cu is higher and has poorer wettability flow to prevent damage to the land of the PWB extreme care should be taken not to leave the bit in contact with the PWB for an extended period oftime Removethebitassoonasagoodflowisachieved The...

Страница 32: ...t or latch hook is damaged 3 The door gasket or seal is damaged 4 The door is bent or warped 5 There are defective parts in the door interlock system 6 There are defective parts in the microwave generating and transmission assembly 7 There is visible damage to the oven Do not operate the oven 1 Without the RF gasket Magnetron 2 If the wave guide or oven cavity are not intact 3 If the door is not c...

Страница 33: ...outer case cabinet 9 Remove the cord bushing and the power supply cord from the outer case cabinet 10 Now the power supply cord or the outer case cabinet is free CAUTION 1 DISCONNECT OVEN FROM POWER SUPPLY BEFORE REMOVING OUTER CASE 2 DISCHARGE THE HIGH VOLTAGE CAPACITOR BEFORE TOUCHING ANY OVEN COMPONENTS OR WIRING Left tab Screws Right tab Hood louver 1 Disconnect the power supply cord and remov...

Страница 34: ... the wire leads from the fuse holder 14 Remove the one 1 screw holding the hood duct R to the oven cavity top plate 15 Remove the hood duct R from the oven cavity top plate 16 Remove the one 1 screw holding the fan duct to the oven cavity top plate 17 Remove the fan duct with the inverter unit and the fan motor from the oven 18 Remove the three 3 screws holding the inverter unit to the fan duct 19...

Страница 35: ...rt a putty knife into the gap between the table tray assembly and the oven cavity front plate And remove the table tray assembly from the oven cavity 2 Install the stirrer motor left one to the oven cavity with the two 2 screws 3 Reconnect the wire lead to the stirrer motor left one referring to the pictorial diagram 4 Make sure that the stirrer motor gear stirrer shaft assembly and shield spring ...

Страница 36: ...ONNECTORS TO THE TERMINALS IN STALL THE POSITIVE LOCK SO THAT THE LEVER FACES YOU POSITIVE LOCK CONNECTOR NO CASE TYPE REMOVAL Positive lock connector 1 Disconnect the power supply cord 2 Open the door and block it open 3 To discharge the high voltage capacitor wait for 60 seconds 4 Remove three 3 screws holding the hood louver to oven cavity front face plate 5 Remove the hood louver from the oven...

Страница 37: ...le tray assembly 3 Remove the table tray assembly from the oven cavity 4 Now the table tray assembly is free Table Tray assembly removal Reinstallation 1 Remove the two 2 stirrer fans 2 Clean the oven cavity bottom plate and or under the antenna plate assembly by a vacuum cleaner 3 Reinstall the two 2 stirrer fans to the stirrer shafts 4 Make sure that the flat edge of the table tray assembly This...

Страница 38: ...front flange fan duct base plate R and magnetron duct And remove the hood intake duct R 5 Remove the control panel assembly referring to the procedure of CONTROL PANEL ASSEMBLY CONTROL UNIT AND KEY UNIT REMOVAL If the stop switch primary interlock switch secondary interlock switch and monitor switch do not operate properly due to a misadjustment the following adjustment should be made 6 Loosen the...

Страница 39: ...f the following 1 Door latch heads smoothly catch latch hook through latch holes and that latch head goes through center of latch hole 2 Deviation of door alignment from horizontal line of cavity face plate is to be less than 1 0mm 3 Door is positioned with its face pressed toward cavity face plate 4 Re install outer case and check for microwave leakage around door with an approved microwave surve...

Страница 40: ...e four 4 screws holding the door panel to the door frame assembly 12 Release the door panel from the door frame assembly NOTE It iseasiertoreleasetheengagingpartsoftheupper or lower door hinge pin side at first 13 Now door frame assembly is free LATCH SPRING LATCH HEAD AND DOOR PANEL 14 Release the latch spring from the tab of the latch head and tab of the door frame 15 Release the latch head from...

Страница 41: ...D RED BLU RED ORG BLK BLK PRIMATY INTERLOCK SWITCH STOP SWITCH SENSOR GROUND WIRE ORG HOOD FAN MOTOR STIRRER MOTOR STIRRER MOTOR 1 2 3 4 5 6 WHT RED YLW BLU BLK WHT RED YLW BLU BLU BLK 2 1 3 4 BRN WHT RED RED ORG ORG RED WHT 1 3 2 YLW PPL 5 4 3 2 1 ORG BLK CN C CN H CN B RY3 N O T1 CN E CN H CN G CN E 1 1 1 3 1 3 2 13 HOOD FAN THERMAL CUT OUT HOOD LAMP AND SOCKETS To GND GRN GRN WHT ORG 9 8 7 6 5 ...

Страница 42: ...40 PMOR3021S PMOR3021B PMOR3021R 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure S 2b Power Unit Circuit ...

Страница 43: ...41 PMOR3021S PMOR3021B PMOR3021R 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure S 3b LSI Unit Circuit ...

Страница 44: ...42 PMOR3021S PMOR3021B PMOR3021R Figure S 4 Printed Wiring Board 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H ...

Отзывы: