Dacor MO Скачать руководство пользователя страница 9

7

1 ¾” (45mm) Min.

to Combustible Floor

“A” 

“B” 

“A” 

“B” 

1 1/2” (38mm) 

Typical Counter 

4“ Typical Toe Kick (Shown) 

Alternate 

Electrical  

Locations 

3/4” (19mm) 

Support Platform 

4“ (102mm) Min. 

Between Cutout 

3/4” (19mm) 

Support Platform 

Recommended Electrical Location 

1“ (25mm) Min. to Combustibles 

36” (914mm)

Typical

Planning the Installation

Duel Single Wall Oven Cutout

Duel Single Wall Oven 
Under Counter Cutout

Single Wall Oven Under 

Counter Cutout

“A” 

“B” 

“A” 

“B” 

“D”

1 ¾“ (45mm)

Min. to Top of

Door for Heat

Exhaust

31 1/4” (794mm) 

Recommended 

(May be Altered) 

4“ Typical Toe Kick (Shown) 

3/4” (19mm) 

Support Platform 

3/4” (19mm) 

Support Platform 

4“ (102mm) Min. 

Between Cutout 

Recommended  

Electrical  

Location 

Recommended  

Electrical  

Location 

Alternate  

Electrical  

Location 

Alternate  

Electrical  

Location 

1“ (25mm) Min.

to Bottom of

Door

36” Typical

(914mm)

1 1/2” 

(38mm) 

Typical Counter 

“A” 

“B” 

1 ¾“ (45mm) Min.

to Combustible Floor

4“ Typical Toe Kick (Shown) 

Recommended 

Electrical  

Location 

3/4” (19mm) 

Support Platform 

1“ (25mm) Min. to Combustibles 

NOtES:

All tolerances are 1/16”, -0 (1.6 mm, -0)

• 

24” minimum cutout depth

• 

3/4” support platform must be flush with 

• 

front of cutout. See page 8.

Содержание MO

Страница 1: ...Installation Instructions Discovery Wall Oven For use with models EO MO and PO Part No 65433 Rev G Preliminary For Review Only No Scheduled Release Date...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved...

Страница 3: ...s completely and care fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the...

Страница 4: ...nless specifically instructed to do so in this manual warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety...

Страница 5: ...with installation con tact your Dacor dealer or the Dacor Customer Service Team When you call have the model and serial num ber of the appliance ready The model and serial num ber are printed on the a...

Страница 6: ...28 3 8 721mm PO130 MOV130 MOV130 EO227 27 686mm 51 3 32 1298mm 49 1 2 1257mm 25 3 8 644mm PO227 MOV227 MOH227 EO230 30 762mm 28 3 8 721mm PO230 MOV230 MOH230 Handle Dimensions All Models Side View Doo...

Страница 7: ...duct Specifications Single Wall Oven Dimension Double Wall Oven Dimension R N P Q M 1 1 16 27mm 66 1676mm Flexible Conduit K L 1 1 4 32mm S M L 1 1 4 32mm P N 1 1 16 27mm R 66 1676mm Flexible Conduit...

Страница 8: ...686mm NA PO227 MOV227 MOH227 EO230 28 1 2 724mm 30 762mm PO230 MOV230 MOH230 Single Wall Oven Cutout Double Wall Oven Cutout Selecting the Location Carefully check the location where the oven is to be...

Страница 9: ...of Door for Heat Exhaust 31 1 4 794mm Recommended May be Altered 4 Typical Toe Kick Shown 3 4 19mm Support Platform 3 4 19mm Support Platform 4 102mm Min Between Cutout Recommended Electrical Location...

Страница 10: ...he oven to malfunction See below Provide a platform within the cabinet to support the oven A properly supported piece of 3 4 19mm thick plywood is recommended All contact surfaces between the applianc...

Страница 11: ...p plied to the appliance from a dedicated grounded single phase circuit that is protected by a properly sized circuit breaker or time delay fuse If a time delay fuse is utilized fuse both sides of the...

Страница 12: ...oduct specifications do not proceed with the installation Call a licensed electrician to install the required wiring To prevent an electric shock or fire hazard turn off power to the circuit at the ci...

Страница 13: ...ding screw The grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a minimum 4 AWG...

Страница 14: ...pper door is removed Remove the oven door s Due to the weight of this appliance remove the door s to reduce the lifting load Removing the door s will also pro vide a place to grip the oven when liftin...

Страница 15: ...abinet Be certain to take all necessary safety precau tions Resting the oven on the cabinet support platform slide 3 the oven into the recessed area until the rear edge of the oven trim post is flush...

Страница 16: ...he use and 5 care manual NOTES If the oven does not operate properly follow these troubleshooting steps Verify that power is supplied to the oven Check for proper electrical connection Repeat the abov...

Страница 17: ...10 Oven is level See page 13 Oven is secured into cabinet with included screws See page 13 Exhaust deflector has been installed See page 14 Oven door s have been properly re installed See page 14 Pla...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: