Dacor IOWO Скачать руководство пользователя страница 8

6

I

nstallatIon

 s

pecIfIcatIons

Support

platform

Chassis

face

I

nstallIng

 

the

 s

upport

 p

latform

 

In

 

the

 c

abInet

Provide a platform (100lb. load capacity) within the cabinet upon 
which the warming oven will be supported. The platform must 
be installed level and straight. The top edge of the platform must 
be flush with the cutout at the front of the cabinet. There are no 
provisions to level the warming oven after it has been installed. 
3/4” (19mm) thick plywood is recommended.

NOTE:

If the oven is not installed in a level fashion, the drawer 
may slide open on its own or may not seal tightly, allowing 
heat to escape and resulting in poor performance.

p

oWer

 s

upply

 r

equIrements

 WARNING

Electric shock Hazard – 

This appliance is equipped 

with a 40” (1016mm) power cord with a three prong 
grounded plug. Plug it only into a grounded three prong 
electrical outlet. 

• Do not remove the ground prong.
• Do not use a 2-prong adapter.
• Do not use an extension cord.
• Do not use a power cord that is frayed or 

damaged.

Failure to comply with the above can result in fire, 
electric shock, or death.

The electrical outlet for this appliance must only be 
installed by a licensed electrician.

Power cord with 

three-prong grounding plug

Grounding type 

electrical outlet

The correct voltage, frequency and amperage must be supplied 
to the electrical outlet from a grounded, single phase circuit that is 
protected by a properly sized circuit breaker or time-delay fuse. 

Circuit Requirements:

120 Vac, 60 Hz, 15 Amp. dedicated circuit.

◊ 

Total Connected Load:

 

 

 

Model EWO36: 0.8kW (6.5 Amp.)

◊ 

All other models: 

◊ 

0.5kW (4 Amp.)

NOTES:

The above specifications are for reference only. Refer 

1. 

to the product date label for exact specifications. If the 
requirements above do not agree with those listed on 
the product data label, use the information found on the 
label. See inside the front cover for location. 

If the electrical service provided does not meet the 

2. 

product specifications, or does not conform to the NEC 
or local standards, do not proceed with the installation.  
Call a licensed electrician to install the required 
electrical service before proceeding. 

3. 

Be certain to locate the electrical outlet in an 
accessible location, so that the warming oven may be 
easily unplugged if service becomes necessary. 

4. 

It is the owner’s responsibility to ensure that the 
electrical outlet for this appliance has been installed 
by a qualified electrician. The electrical installation 
must comply with the latest revision of the National 
Electric Code ANSI/NFPA 70 and local codes and 
ordinances.

Содержание IOWO

Страница 1: ...Installation Instructions Warming Oven For use with models EW EWO MW MWO PW PWO IWO IOWO Part No 65034 Rev K...

Страница 2: ...stallation instructions completely before you begin the installation process Leave these installation instructions with the homeowner HOMEOWNER Keep these installation instructions for future referenc...

Страница 3: ...at and cook food It is not designed for industrial or laboratory use 5 As with any appliance close supervision is necessary when used by children 6 Do not operate this appliance if it has a damaged el...

Страница 4: ...sions 10 1 8 257mm Drawer Face Dimensions MW Shown Warming Oven Overall Dimensions Model C Drawer Face Width D Chassis Face Width E Chassis Width EWO24 23 7 8 606mm 23 11 16 602mm 22 3 16 564mm EW27 2...

Страница 5: ...g holes rear holes IOWO model only K Chassis Dimensions IOWO Shown Chassis Drawer open J G E C Overall Dimensions Top View Integrated Warming Oven Overall Dimensions Warming Oven Model No Dimension C...

Страница 6: ...ation The oven should be placed for convenient access Make certain that electrical power can be provided in the selected location Plan the installation so that all minimum clearances are met or exceed...

Страница 7: ...19mm 5 8 Min 16mm 120 Vac electrical outlet A 36 Typ 914mm B C A Warming Oven Warming Oven OB Outdoor Grill EG Epicure Gas Cooktop B 3 4 Min 19mm D 5 8 Min 16mm 120 Vac electrical outlet 36 typ 914mm...

Страница 8: ...rd with three prong grounding plug Grounding type electrical outlet The correct voltage frequency and amperage must be supplied to the electrical outlet from a grounded single phase circuit that is pr...

Страница 9: ...nstalling the mounting screws Install one mounting screw through the hole provided in the front A pair of holes go through the side of the chassis for mounting to the cabinet walls continued Removing...

Страница 10: ...to the instructions on page 6 Has the chassis been properly fastened to the mounting platform and sides of the cabinet See page 7 Has the drawer been properly installed Has proper operation been veri...

Страница 11: ......

Страница 12: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: