3
NOTE:
The ILB8 & ILB10 inline blowers
are only approved in updraft
(hood) applications.
NOTE:
The REMP must be sealed
between the roof or wall and
the underside of the flange with
mastic to prevent leaks. For
installation on a flat roof, or a
roof with a pitch of less than 2:12,
install the REMP on a curb as
shown below. Position the curb
on flat roofs so that the discharge
(low) end points away from the
prevailing wind.
RV
REMP
Dacor Preference
and Millennia Cooktops
AIR
3 1/4" x 10"
90° Elbow
3 1/4" x 10"
90° Elbow
3 1/4" x 10" to
Round
Transistion
45° Adjustable
Elbow
Air
Discharge
REMP Roof Installation
Side View
Roof Curb
REMP Flat Roof Installation
Sealant
Air
Discharge
Sealant
REMP
Round Duct
45° Adjustable
Elbow
Flange
REMP Sloped Roof Installation
25 1/2"
(648mm)
2"
(51mm)
19"
(483mm)
23 1/4"
(591mm)
6"
(152mm)
2"
(51mm)
REMP3 Sloped Roof Installation
33 1/2"
(851mm)
2"
(51mm)
26"
(660mm)
30 1/2"
(776mm)
6"
(152mm)
2"
(51mm)
REMP16 Roof Curb Dimensions
Electrical Connection
WARNINGS:
1. Ensure that the power supply
is disconnected before
proceeding.
2. Verify that the power supply
matches the ratings found on
the appliance data plate before
proceeding.
3. The complete appliance must
be properly grounded at all
times when electrical power is
applied.
4. Do not ground the appliance
with the neutral (white) house
supply wire. A separate
ground wire must be utilized.
5. If aluminum house supply
wiring is used, splice the
appliance copper wires to the
aluminum house wiring with
special connectors designed
and agency-certified for this
purpose. Follow the connector
manufacturer’s recommended
procedure carefully. Improper
connection can result in a fire
hazard.
6. Failure to complete electrical
connections properly may
result in a damaged or non-
functional system. Follow the
wiring diagrams carefully to
ensure a proper installation.
It is the owner’s responsibility to ensure that
a qualified electrician performs the electrical
connection of this appliance. The electrical
installation, including minimum supply wire
size, must comply with the latest revision of the
National Electric Code ANSI/NFPA 70* and local
codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
NOTES:
1. Make all electrical connections
between the vent and blowers,
then connect power to the
vent as per the wiring diagram
shown.
2. Use wire nuts and electrical
tape to secure all wiring
connections at the blowers.