background image

9

Installation Instructions

Connecting the Gas Line

 WARNING

• Before connection, ensure the gas supply meets speci-

fications (Pg. 4).

• Install the included gas regulator before you install/use

the cooktop.

• Ensure the arrow on the regulator points in the direction

of the gas flow (toward the cooktop).

• Do not overtighten the gas connections/fittings.
• Do not use Teflon tape or plumber’s putty on flexible

gas-line connections.

• Before use, test the gas lines for leaks as instructed.

Do not use a flame to check for leaks.

• The gas-supply pressure to the regulator must not

exceed 1/2 psi (pounds per square inch) or 3.5 kPa.

• The cooktop and shut-off valve must be disconnected

from the gas-supply piping system during any pressure

test over 1/2 psi (3.5 kPa).

• You must close the shut-off valve to the cooktop during

any gas-supply piping-system pressure testing equal to

or less than 1/2 psi (3.5 kPa).

• For LP (liquid propane) gas installations, the tank must

have its own high-pressure regulator besides the pres-

sure regulator supplied with the cooktop.

1. Attach the gas-pressure regulator (included) to the

cooktop gas inlet.
(Tight spaces) Install the regulator anywhere between

the cooktop and gas-supply/shut-off valve.
To minimize gas-pressure loss, attach the regulator as

close to the cooktop as possible.
Use a minimum 1/2” flexible gas line (not included) to

connect the regulator to the gas-supply/shut-off valve.

2. Check for gas leaks:

a. Turn OFF all cooktop control valves.
b. With a soap-water solution or gas-leak detector,

check all lines/connections for leaks. (Ensure the

gas-supply/shut-off valve is ON.)

c. Turn the gas supply/shut-off valve OFF.

Verifying Package Contents

• Hold-down brackets (2)
• Gas-pressure regulator (1)
• Grates: (3)
• Burners: (6)
• Stainless-steel cleaner (1)
If parts are missing, see the 

Replacement Parts

 (Pg.

12) for ordering information.

Installing the Cooktop

 WARNING

• Before proceeding, verify that the power supply meets

the specifications on Page 4.

• To avoid damaging the gas-pressure regulator, install it

after

 mounting the cooktop in its permanent position.

 IMPORTANT

• Do not overtighten the hold-down bolts; overtightening

may keep the dual gas burners from operating properly.

• Do not seal the cooktop to the counter; the cooktop

must be easily removable for service. The customer is

financially responsible for the added task of removing

sealing compounds in the course of servicing the unit.

If a downdraft vent will be used, first install the vent 

according to its installation instructions.

1. Lower the cooktop into the cutout and center it.
2. Secure the cooktop to the countertop using the hold-

down brackets as shown.

Beneath the Cooktop

Hold-down bracket 

mounting holes

Gas inlet

Содержание HPCT466GS

Страница 1: ...Installation Instructions Heritage Gas Cooktop HPCT466GB HPCT466GS Part No 113930 Rev A...

Страница 2: ...fore you begin the installation process Leave this Installation Instruction manual with the consumer Consumer Keep this Installation Instruction manual for future reference and for the local electrica...

Страница 3: ...hrough the cooktop and may cause carbon monoxide poisoning Aluminum foil linings may also trap heat causing a fire hazard Keep all slots holes and passages clear of grease and grime WARNING If the inf...

Страница 4: ...attended near the cooktop nor let them touch its controls or any other parts Do not store items of interest to children on or above the cooktop as children could be burned injured while climbing on th...

Страница 5: ...3 Installation Specifications All tolerances 1 16 unless otherwise noted Product Dimensions Model HPCT466G...

Страница 6: ...s equipped for high eleva tion operation Units equipped for liquid propane have LP in the model number on the product data label previous graphic Units equipped for high elevation use have an H at the...

Страница 7: ...paired with a suitable vent hood or approved Dacor downdraft CLEARANCE REQUIREMENTS Model A Minimum A Recommended HPCT466G 46 in 121 9 cm 54 in 137 2 cm Installation Specifications Under Chassis Clea...

Страница 8: ...the correct diagram before cutting the countertop CUTOUT TYPE AND DIMENSIONS Configuration Cutout Type C Min D E F G H HPCT466G no downdraft Square 2 7 8 in 7 3 cm 19 3 4 in 50 2 cm 44 1 2 in 113 03...

Страница 9: ...7 Installation Specifications All tolerances 1 16 unless otherwise noted Square Cutout Notched Cutout...

Страница 10: ...Countertop Floor 5 8 in min 1 6 cm space needed behind downdraft vent chassis to clear stiffener 4 5 8 in 11 7 cm 9 7 8 in 25 1 cm with CABP3 blower installed RV Series Downdraft Check downdraft spec...

Страница 11: ...the regulator as close to the cooktop as possible Use a minimum 1 2 flexible gas line not included to connect the regulator to the gas supply shut off valve 2 Check for gas leaks a Turn OFF all cookto...

Страница 12: ...pa nying User Manual Running the Ignition Test This test verifies the proper function of each burner and its corresponding control knob 1 Ensure all cooktop burner controls are turned OFF and plug in...

Страница 13: ...e cover of this manual for the location of these numbers Dacor shall not pay to correct problems caused by a faulty installation Installation Instructions Installation Checklist WARNING The installer...

Страница 14: ...Part Name Part Hold down brackets w screws 2 sets 82540 Stainless steel cleaner stainless steel only 108850 HPCT466GS GB Part Name Location Type Part Regulator Natural gas 62320 Liquid propane 62434 G...

Страница 15: ...ram AFTER SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPERAND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABELALLWIRES PRIORTO DISCONNECTION WIRING DI...

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: