Verifying the Package Contents

• Use and Care Manual

• Anchoring Legs

Installation Planning

A qualified technician must complete the 

installation of this appliance. Proper installation 

is your responsibility.

Raised Vent System Specifications

Raised Vent 

Model No

.

For Use with

For Use with Blower

Duct Size

ERV/PRV30

30” Ranges/Cooktops

REMP3/16

3 1/4”x10”, 8” & 10”

ERV/PRV36

36” Cooktops

REMP3/16

3 1/4”x10”, 8” & 10”

PRV46

46” Cooktops

REMP3/16

3 1/4”x10”, 8” & 10”

ERV48

48” Cooktops

REMP3/16

3 1/4”x10”, 8” & 10”

For detailed information on the remote blowers, refer to the Remote Blowers Installation Instructions.

Duct Planning

wARNINgS

1.  To reduce the risk of fire and 

to properly exhaust air, ducted 

fans must be vented to outside. 

Do not vent exhaust air into 

spaces within walls, ceilings, 

attics, crawl spaces or garages.

2.  Improper installation, 

adjustment, alteration, service, 

or maintenance can cause 

personal injury or property 

damage.

3.  To reduce the risk of fire, 

use only ductwork materials 

deemed acceptable by state, 

municipal and local codes.

wARNINg: 

Failure to disconnect power may 

result in electrical shock or fire 

hazard! If the electric service 

provided does not meet the 

product specifications, do not 

proceed with the installation. Call 

the selling dealer or a licensed 

electrician.
Electrical Power Supply 

Requirements

It is the owner’s responsibility to ensure that 

the electrical connection of this appliance 

is performed by a qualified electrician. The 

electrical installation, including minimum supply 

wire size and grounding, must be in accordance 

with the National Electric code ANSI/NFPA 70-

2002* (or latest revision) and local codes and 

ordinances. 

*A copy of this standard may be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, Massachusetts 02269-9101 

The correct 120VAC, 60Hz, 15A circuit must 

be supplied for this appliance from a separate, 

grounded, circuit that is protected by a properly 

sized circuit breaker or time delay fuse.

NOTES:

1.  Best performance is achieved 

by using round duct instead of 

rectangular, especially when 

elbows are required.  

2.  If multiple elbows are needed, 

ensure that there is a minimum 

of 24” of straight duct between 

any two elbows. 

3.  Avoid “S” or “back to back” 

configurations caused by 

adjacent elbows. 

ERV / PRV Overall Dimensions

Side View

ERV / PRV Overall Dimensions

Front View

Model

width “A”

width “B”

ERV/PRV30

30” (762mm)

27 3/4” (705mm)

ERV/PRV36

36” (914mm)

33 3/8” (848mm)

PRV46

46” (1168mm)

43 3/8” (1102mm)

ERV48

48” (1219mm)

43 3/8” (1102mm)

Overall Dimensions

8 1/2"

(216mm)

6 5/8”

(168mm)

10"

(254mm)

30"

(762mm)

18 13/16”

(478mm)

1 5/8" x 16"

Exhaust duct

Stiffener 

3 3/4"

(95mm)

3/4"

(19mm)

Finished floor 

1 5/8" x 16"

Exhaust duct

3 1/4" x 10" 

Rear

Exhaust duct

1 5/8" x 16"

Exhaust duct

1 5/8" x 16"

Exhaust duct

48", 3 prong 

grounded

power cord

Electrical

access panel

Countertop

Motor

cover

6"

(152mm)

3 1/4" x 10"

Exhaust duct

25 7/8"

(657mm)

2 13/16"

(71mm)

Cooktop/Range

Stud wall 

Wall board 

3/4"  (19mm) Max. backsplash thickness 

1/4" (6mm) Min. flat area 

3"

(76mm)

9/32" (7mm)

1 15/16"

(49mm)

“B”

“A”

ATD2 

4"

(102mm)

Содержание ERV30

Страница 1: ...ements Page 2 Duct Planning Pages 2 3 Countertop and cabinet preparation Pages 4 5 Installing the ERV PRV Page 5 Connecting the exhaust duct Page 5 Electrical connection Pages 5 6 Cooktop Range instal...

Страница 2: ...ng or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented outdoors e To reduce the risk of fire use only metal duct work to ins...

Страница 3: ...ce is performed by a qualified electrician The electrical installation including minimum supply wire size and grounding must be in accordance with the National Electric code ANSI NFPA 70 2002 or lates...

Страница 4: ...work meets the maximum duct length requirement proceed with the location planning Finished floor 3 1 4 x 10 90 Elbow 3 1 4 x 10 90 Elbow ERV36 Motor cover Epicure 36 Cooktop ERV36 Wall board Counterto...

Страница 5: ...top overhangs cabinet 6 152mm Min to combustible side walls above the range both sides 27 7 8 708mm Adjust for backsplash over 3 4 thick from 13 16 to 3 13 16 21 97mm Backsplash thicker than 3 4 19mm...

Страница 6: ...ground wire must be utilized 5 If aluminum house supply wiring is used splice the appliance copper wires to the aluminum house wiring with special connectors designed and agency certified for this pur...

Страница 7: ...ference may result in permanent damage to the vent Verifying the Operation Warnings 1 If the vent system is not operational after completion of the installation do not attempt to repair it See the Pro...

Страница 8: ...NOTES...

Страница 9: ...NOTES...

Страница 10: ...NOTES...

Страница 11: ...10 NOTES...

Страница 12: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Отзывы: