PLANNING

GUIDE

www.Dacor.com      Phone: (800) 793-0093  

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

5.9

Epicure

®

 Ranges

ER30D, ER30DSR

ER30DSR with

H

J

K

no side panels no raised vent

23 1/2” (597 mm)

23 1/2” (597 mm)

24” to 25 9/16”

3-inch side panels* and no raised vent

20 1/2” (521 mm)

20 1/2” to 23 1/2”

21” to 25 9/16”

no side panels and raised vent

24” (610 mm)

24” (610 mm)

24 1/2” to 26 1/16”

3-inch side panels and raised vent

21” (533 mm)

21” to 24”

21 1/2” to 26 1/16”

Cutout tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated

toP VIEw - moDEL ER30DSR CoUNtERtoP/CAbINEt  

CUtoUt DImENSIoNS SELf RImmING INStALLAtIoN 

Non-combustible

rear wall recommeded

Countertop Height: Min: 35 5/8” (905 mm) Max: 37 3/8” (949 mm) 

Combustible side

wall above range

countertop opening

29 1/2” (749 mm)

30” (762 mm)

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

overhang to width of

cabinets

1/4” Min. (6 mm)

 Countertop

overhang

10” Min.

(254 mm)

both sides

Countertop front

H J K

rear wall recommended

Non-combustible

countertop opening

cabinet opening

below countertop

29 1/2” (749 mm)

27 1/2” (699 mm)

30” (762 mm)

2 3/8” (60 mm)

Combustible side

wall above range

10” Min.

(254 mm)

both sides

Countertop Height: Min: 35 5/8” (905 mm) Max: 37 1/4” (946 mm) 

Notch countertop

overhang to width of

cabinets

3/8” Min. (10 mm)

Countertop

overhang

below countertop

Cabinet face

raised vent  opening

H J K

Countertop front

toP VIEw - moDEL ER30DSR CoUNtERtoP/CAbINEt 

CUtoUt DImENSIoNS, SELf RImmING INStALLAtIoN 

wIth RAISED VENt (Atk30SR tRIm kIt INStALLED)

APPRoVED RAISED VENtS: ERV30 oR PRV30 

Stiffener

Cabinet face*

Countertop*

IMPORTANT

: See Countertop/Cabinet Cutout Dimensions 

for countertop cutout dimensions.

** 

IMPORTANT

: If optional 3-inch side panels are not installed

cabinet face must be flush with back of control panel. 

Back of

control

panel

ERV30 or

PRV30

raised vent

ER30DSR Range: 

ATK30SR trim kit 

required for installation

with raised vent

3/8” Min. (10 mm)

space behind

raised vent 

chassis to clear

stiffener

Shown with

optional 3-inch

side panels

installed**

3/8” Min. (10 mm)

flat countertop overhang

required behind cutout

Countertop height:

35 5/8" (905 mm) Min.

37 1/4” (946 mm) Max.

Document # PG05-003

Revised 08/23/10   Page 3/3