With the door closed, reattach the kick panel to the range
by snapping the ball studs on the back of the panel into the
holes on the front panel of the range.
Open the door and reattach the kick panel top screws
removed in step 1.
Installing a Raised Vent (Optional)
Install the ERV30 or PRV30 raised vent before final installation
of the range. See the raised vent installation instructions, part no.
65335.
IMPORTANT:
The ERV30 or PRV30 raised vent attaches to the
narrow back portion of the raised vent/range cutout. It is self-
supporting in the cutout and does not actually attach to the range
itself.
9.
10.
Reattach kick panel
with existing screws
Space between
door and oven
opening
Installation Instructions
Level and Adjust the Range Height
Raise or lower the range to prepare for final installation:
For model ER30D and ER30D-C, adjust the height until
the top edge of the trim around the edge of the of the
cooktop is slightly higher than the countertop.
For model ER30DSR, raise the range until bottom edge
of the trim around the edge of the of the cooktop is 1/8”
higher than the countertop.
Install the Anti-Tip Bracket and Foot
Locate the anti-tip foot and lower it until it is 1/16" (2 mm) off
the floor.
Locate the anti-tip bracket included in the parts box.
Install the anti-tip bracket on the floor using the four (4)
included screws. See the diagram below for location.
ANTI-TIP BRACKET PLACEMENT
A
6 5/8” (168 mm)
B
6 3/8” (162 mm)
1.
◊
◊
1.
2.
3.
A
B
Top View
Back of
Range
Range
Right
Side
Back of
Range
2 1/8” *
down
up
Rear
Leg
* Distance to floor: 2 7/16” to 4 9/16”
Back of Range
Anti-Tip Foot Location