Dacor Epicure EOG36 Скачать руководство пользователя страница 10

8

I

nstallatIon

 I

nstructIons

Gas Connections

 WARNINGS:

Natural Gas Connections

Verify gas supply pressures are acceptable based on the table on 

page 6.

The Dacor outdoor cooking products ship with a 3/4 inch nipple, 

regulator, and 1/2” reducer for gas supply connections.

Install a 3/4 inch (19mm) or 1/2 inch (13mm) natural gas supply 

line, with a shut off valve (not included with the outdoor product), 

in an accessible location under the appliance. Place the gas 

supply line and shut off valve inside the base enclosure within a 

reachable distance from the front access doors or open rear area 

of the enclosure. Refer to base enclosure planning and cutout 

dimensions page within this manual for additional detail. 

.

Connect the, factory supplied, regulator and gas line nipple at the 

back right bottom corner of the grill. Use only approved gas line 

thread compound, regulators, and gas hose. Be certain the gas 

flow arrow on the regulator is installed with the flow in the correct 

direction.  

Install approved flexible gas line from the regulator to the rough 

gas line shut off valve using the factory supplied regulator.

Check all gas connections for leaking by applying a water and 

soap solution. If you observe leakage (soap bubbles around any 

connections) do not attempt to operate the grill without correcting 

the leak.

Liquid Propane (LP) Connections

1.  A dented or rusty LP tank may be hazardous and 

should be checked by your LP supplier.

2.  Never use a cylinder with a damaged valve.

3.  A Portable Liquid Propane tank should be a 5 

gallon, 20 lb. gas cylinder approximately 12 inches 

(305mm) in diameter and 18 inches (457mm) 

high, which must be constructed and marked 

in accordance with the specification for Liquid 

Propane (LP) gas cylinders of the U.S. Department 

of Transportation (DOT) and designed for use with 

a 5LP-A quick disconnect systems only.

4.  Do not change the regulator/hose assembly with a 

standard 510 POL tank/valve assembly.

5.  The cylinder must be provided with a shut-

off valve terminating in a Liquid Propane (LP) 

gas supply cylinder valve outlet specified, as 

applicable, for connection No. 5LP-A.

6.  The cylinder supply system must be arranged 

for vapor withdrawal and provided with a listed 

overfilling prevention device.

7.  If the appliance is stored indoors, the cylinder 

must be disconnected and removed from the 

appliance.

8.  Cylinders must be stored outdoors in a well 

vented area out of the reach of children.

Make sure the LP tank main valve is completely closed before 

proceeding with the installation.

1.  In the event of a power failure. Use Dacor supplied 

match lite tool.

2.  Verify that the proper electrical power supply has 

been provided.

3.  Verify that the electrical supply matches the 

ratings found on the appliance data plate before 

proceeding.

4.  This appliance must be connected to a grounded, 

metallic, permanent wiring system. Alternatively, 

a grounding conductor should be connected to 

the grounding terminal or lead on the appliance. 

Failure to do so may result in an electrical shock 

hazard.

5.  Do not use an extension cord with this appliance. 

Such use may result in fire, electrical shock, or 

other personal injury.

6.  Do not install a fuse in the neutral or ground 

circuit. A fuse in the neutral or ground circuit may 

result in an electrical shock hazard.

7.  Do not ground this appliance to a gas supply pipe 

or hot water pipe.

8.   Keep any electrical supply cord and the fuel 

supply hose away from any heated surfaces.

Plug the factory supplied, three-prong plug located at the bottom 

back right corner of the grill into the grounded receptacle.

Also, install the rotisserie motor and spit at this time (Use and 

Care instruction for proper rotisserie installation) be sure to plug 

only into a grounded receptacle. 

Connecting the Electrical

 WARNINGS:

Install the LP regulator and gas hose on the grill main gas stub at 

the right rear corner of the appliance. Follow all regulator and gas 

line instructions as noted in the warnings above.

Place the tank into the final position within the base enclosure or 

cart.

NOTE:

The Dacor outdoor grills are approved for installation 

on typical whole-house LP gas supply systems.  For 

proper whole-house LP gas installation order Dacor 

part # 72601.

Three-Prong Plug

Three-prong grounded receptacle 

and cover plate

Three-Prong Plug and Receptacle

Содержание Epicure EOG36

Страница 1: ...Installation Instructions Epicure Outdoor Grill For use with models EOG303 EOG36 EOG52 EOSB162 Part No 65249 Rev F...

Страница 2: ...nal injury or death CAUTION CAUTION Hazards or unsafe practices which COULD result in minor personal injury or property damage CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuel generat...

Страница 3: ...ubes for insects and insect nests A clogged tube can lead to a fire beneath the grill 9 Outdoor gas cooking appliances shall be used only outdoors and shall not be used in a building garage or any oth...

Страница 4: ...52 28 711mm EOSB162 EOG303 36 52 Cutout Dimensions Top View 9 1 8 232mm 23 584mm 26 3 8 670mm 27 1 8 689mm 30 762mm 23 584mm EOG303 Overall Dimensions 9 1 8 232mm 23 584mm 26 3 8 670mm 27 1 8 689mm 36...

Страница 5: ...trical connection gas shut off valve and pressure regulator are accessible inside the base enclosure 5 All MINIMUM electrical and gas dimensions are illustrated in the drawings within this manual Util...

Страница 6: ...tilizing the deck screws and holes located along the vertical sides of the finish trim install them securely to the base enclosure countertop sub straight Install the trim before installing the grill...

Страница 7: ...ne 11 Water Column 12 Water Column EOG52 Natural 4 Water Column 7 Water Column EOG52LP Liquid Propane 11 Water Column 12 Water Column EOSB162 Natural 4 Water Column 7 Water Column EOSB162LP Liquid Pro...

Страница 8: ...ural gas installations will be connected to factory supplied natural gas regulator Refer to Natural gas connections in this manual for details 8 Inspect the gas line before and after installation Also...

Страница 9: ...two fasteners located in the front right corner behind the horizontal support temporarily creating a 1 2 gap between the support rail and right side panel 4 Remove the EOG from its shipping carton and...

Страница 10: ...utlet specified as applicable for connection No 5LP A 6 The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device 7 If the appliance is...

Страница 11: ...ON the main tank valve then turn all burners ON to the high position for approximately 20 seconds to allow the air in the system to purge from the grill and cooktop side burners Once the gas has fill...

Страница 12: ...0Hz HALOGEN LIGHTS TRANSFORMER BR 10W 12V RIGHT HALOGEN LIGHT BR BR W BK RED RED EOG303 Electrical Schematic GN W BK PLUGS IGNITION 4 POINT RE IGNITOR S2 S4 S3 S1 GN N A 3 4 S4 S3 2 1 S2 S1 LIGHTS IND...

Страница 13: ...ONT SIDE BK BURNER REAR SIDE BK BURNER LEFT GRILL BK CENTER GRILL BURNER BK RIGHT GRILL BURNER BK O BK BK BK BK S2 BK BK W S1 W BK BK W BK BK BK S3 S4 S5 GN W W BK BK BK BK BK S6 BK BK BK BK BK W W W...

Страница 14: ...he model and serial numbers when you call You ll find these numbers on the serial number plate located on the light shield in the fresh food compartment Contact a Dacor authorized servicer a Dacor dea...

Страница 15: ......

Страница 16: ...ained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc 2006 Distinctive Appliances Inc all rights reserved Specifications contained...

Отзывы: