![Dacor Epicure EOG36 Скачать руководство пользователя страница 10](http://html2.mh-extra.com/html/dacor/epicure-eog36/epicure-eog36_installation-instructions-manual_3186574010.webp)
8
I
nstallatIon
I
nstructIons
Gas Connections
WARNINGS:
Natural Gas Connections
Verify gas supply pressures are acceptable based on the table on
page 6.
The Dacor outdoor cooking products ship with a 3/4 inch nipple,
regulator, and 1/2” reducer for gas supply connections.
Install a 3/4 inch (19mm) or 1/2 inch (13mm) natural gas supply
line, with a shut off valve (not included with the outdoor product),
in an accessible location under the appliance. Place the gas
supply line and shut off valve inside the base enclosure within a
reachable distance from the front access doors or open rear area
of the enclosure. Refer to base enclosure planning and cutout
dimensions page within this manual for additional detail.
.
Connect the, factory supplied, regulator and gas line nipple at the
back right bottom corner of the grill. Use only approved gas line
thread compound, regulators, and gas hose. Be certain the gas
flow arrow on the regulator is installed with the flow in the correct
direction.
Install approved flexible gas line from the regulator to the rough
gas line shut off valve using the factory supplied regulator.
Check all gas connections for leaking by applying a water and
soap solution. If you observe leakage (soap bubbles around any
connections) do not attempt to operate the grill without correcting
the leak.
Liquid Propane (LP) Connections
1. A dented or rusty LP tank may be hazardous and
should be checked by your LP supplier.
2. Never use a cylinder with a damaged valve.
3. A Portable Liquid Propane tank should be a 5
gallon, 20 lb. gas cylinder approximately 12 inches
(305mm) in diameter and 18 inches (457mm)
high, which must be constructed and marked
in accordance with the specification for Liquid
Propane (LP) gas cylinders of the U.S. Department
of Transportation (DOT) and designed for use with
a 5LP-A quick disconnect systems only.
4. Do not change the regulator/hose assembly with a
standard 510 POL tank/valve assembly.
5. The cylinder must be provided with a shut-
off valve terminating in a Liquid Propane (LP)
gas supply cylinder valve outlet specified, as
applicable, for connection No. 5LP-A.
6. The cylinder supply system must be arranged
for vapor withdrawal and provided with a listed
overfilling prevention device.
7. If the appliance is stored indoors, the cylinder
must be disconnected and removed from the
appliance.
8. Cylinders must be stored outdoors in a well
vented area out of the reach of children.
Make sure the LP tank main valve is completely closed before
proceeding with the installation.
1. In the event of a power failure. Use Dacor supplied
match lite tool.
2. Verify that the proper electrical power supply has
been provided.
3. Verify that the electrical supply matches the
ratings found on the appliance data plate before
proceeding.
4. This appliance must be connected to a grounded,
metallic, permanent wiring system. Alternatively,
a grounding conductor should be connected to
the grounding terminal or lead on the appliance.
Failure to do so may result in an electrical shock
hazard.
5. Do not use an extension cord with this appliance.
Such use may result in fire, electrical shock, or
other personal injury.
6. Do not install a fuse in the neutral or ground
circuit. A fuse in the neutral or ground circuit may
result in an electrical shock hazard.
7. Do not ground this appliance to a gas supply pipe
or hot water pipe.
8. Keep any electrical supply cord and the fuel
supply hose away from any heated surfaces.
Plug the factory supplied, three-prong plug located at the bottom
back right corner of the grill into the grounded receptacle.
Also, install the rotisserie motor and spit at this time (Use and
Care instruction for proper rotisserie installation) be sure to plug
only into a grounded receptacle.
Connecting the Electrical
WARNINGS:
Install the LP regulator and gas hose on the grill main gas stub at
the right rear corner of the appliance. Follow all regulator and gas
line instructions as noted in the warnings above.
Place the tank into the final position within the base enclosure or
cart.
NOTE:
The Dacor outdoor grills are approved for installation
on typical whole-house LP gas supply systems. For
proper whole-house LP gas installation order Dacor
part # 72601.
Three-Prong Plug
Three-prong grounded receptacle
and cover plate
Three-Prong Plug and Receptacle
Содержание Epicure EOG36