4

NOTES: 

1.  Best performance is achieved by 

using round duct instead of rect-

angular, especially when elbows 

are required.  

2.  If  multiple  elbows  are  needed, 

ensure  that  there  is  a  minimum 

of  24”  of  straight  duct  between 

any two elbows. 

3.  Avoid “S” or “back to back” con-

figurations  caused  by  adjacent 

elbows. 

4.  Thermal breaks, such as a short 

section  of  non-metallic  duct, 

should  be  used  in  areas  of 

extreme cold.  

5.  A back-draft damper at the duct 

outlet may also be required.

6.  Do not use flexible metal duct. 
7.  Do  not  use  duct  work  that  is 

smaller  in  cross-sectional  area 

than  the  recommended  size 

duct.

8.  Do not rely on duct tape alone to 

seal duct joints. Use sheet metal 

screws as require to support the 

duct weight.

9.  The  vent  hood  and  cooking 

appliance(s) must be removable 

if service is required.

10. Be  certain  that  the  duct  work 

does  not  interfere  with  floor 

joists or wall studs.

11.  It  is  important  to  keep  as  few 

turns in the duct run, and to keep 

the run as short as possible.

12. EhDR  series  hoods  are  not 

equipped with an internal blower. 

Installation  of  an  in-line  (Dacor 

model  ILB8)  or  remote  

blower  (Dacor  model 

REMP3)  is  required.  

Install  the  in-line  or 

remote blower according 

to  the  blower  installa-

tion  instructions  before 

installing the hood.

13. If  installing  an  in-line 

blower, it must be locat-

ed  within  60  equivalent 

feet  of  the  hood  canopy 

system.

Model  

Series

Duct

 

Size

Maximum Equivalent 

Straight Lengths

Internal 

Blower

ILB8

REMP3

EHD 

MHD

8” Round

60’

NA

NA

10” Round

50’

NA

NA

3 1/4” x 10”

50’

NA

NA

EHDR 

MHDR

8” Round

NA

60’

60’

10” Round

NA

50’

50’

3 1/4” x 10”

NA

50’

50’

Recommended Maximum Straight Lengths

3 1/4" x 10" 

90° Elbow

3 1/4" x 10"

45° Elbow

Roof Cap or

Wall Cap with Damper

3 1/4" x 10"

90° Flat Elbow

Transistion

3 1/4" x 10" to Round

45° Elbow

Round Duct

90° Transistion

3 1/4" x 10" to 

8" Round

90° Elbow

Round Duct

15 Feet

7 Feet

30 Feet

20 Feet

8" Diameter - 4 Feet

10" Diameter - 4 Feet

8" Diameter - 3 Feet

10" Diameter - 2 Feet

25 Feet

8" Diameter - 7 Feet

10" Diameter - 5 Feet

Recommended sheet metal elbows, transition, and wall cap 

equivalent straight lengths

Electrical Power Supply 

Requirements

NOTES:

1.  If the power supply 

requirements shown do 

not agree with those listed 

on the product data plate, 

provide a power source per 

the information found on the 

product data plate. 

2.  If the electrical service 

provided does not meet the 

product specification, or 

does not conform to the NEC 

or local standards, do not 

proceed with the installation.  

Call a licensed electrician to 

correct the electrical service 

before proceeding.

Electrical Supply Requirements

  120 Vac, 60 Hz, 15 Amp. Dedicated 

Circuit

Total Connected Load

  1.4 kW (12 A)

The correct voltage, frequency and amper-

age must be supplied to the appliance from 

a separate, grounded, circuit that is pro-

tected by a properly sized circuit breaker 

or time delay fuse. Refer to the data plate 

located on the blower housing, inside the 

filter area. The specifications below are 

provided for reference and do not super-

sede the information on the product data 

plate.

Refer to the table below for recommended 

maximum straight lengths of duct to pro-

vide adequate performance.  Refer to  the 

table above for recommended sheet metal 

elbows, transitions, and wall cap equivalent 

straight lengths.

3.  It is the owner’s responsibility 

to ensure that electrical 

installation of this appliance 

is performed by a qualified 

electrician. The electrical 

installation must comply 

with the National Electric 

Code ANSI/NFPA 70-1990 (or 

to latest revision) and local 

codes and ordinances.

4.  Failure to disconnect electric 

power may result in electrical 

shock or fire hazard.

Содержание Epicure EHD3018

Страница 1: ...ions Page 2 Cabinet preparation Page 3 Duct planning Page 3 Electrical power supply requirements Page 4 Installing the hood Page 4 Connecting the electrical power Page 4 Verifying proper operation Pag...

Страница 2: ...xception The additional safety instructions do not apply to a ceiling suspended fan 11 For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors WARNING To red...

Страница 3: ...ing NOTE All tolerances 1 16 0 unless otherwise stated Overall Dimensions Overall Dimensions MHD Series Shown 9 High Hood Overall Dimensions 11 7 8 302mm A 18 457mm B Overall Dimensions MHD Series Sho...

Страница 4: ...Locations 1 1 2 38mm 7 8 11mm Holes A B C L C L C L C L Rear of hood Vertical Electrical Access Hole Locations Top View C L 3 4 19mm 7 8 11mm Holes Top of hood C D C L C L C L Horizontal Electrical A...

Страница 5: ...Flat Elbow Transistion 3 1 4 x 10 to Round 45 Elbow Round Duct 90 Transistion 3 1 4 x 10 to 8 Round 90 Elbow Round Duct 15 Feet 7 Feet 30 Feet 20 Feet 8 Diameter 4 Feet 10 Diameter 4 Feet 8 Diameter...

Страница 6: ...in a fire hazard 6 Failure to complete electrical connections properly may result in a damaged or a non functional system Follow the wiring diagrams carefully to ensure a proper installation Model EH...

Страница 7: ...6...

Страница 8: ...Web Site www Dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Отзывы: