Dacor EORD227S Скачать руководство пользователя страница 6

4

Power Supply Requirements

• 

It is the owner’s responsibility to ensure that a licensed 

electrician performs the installation of the electrical sup-

ply for this appliance. The electrical installation, includ-

ing minimum supply wire size, must comply with the 

National Electric Code ANSI/NFPA 70 (latest revision) 

and local codes and ordinances.

A copy of this standard may be obtained from:

• 

The correct voltage, frequency and amperage must be 

supplied to the appliance from a dedicated, grounded, 

single phase circuit that is protected by a properly sized 

circuit breaker or time-delay fuse. If a time-delay fuse is 

utilized, fuse both sides of the line (L1 and L2).

• 

The required voltage, frequency and amperage ratings 

are listed on the appliance data plate (see page 3) and 

in the table for reference.

• 

Preheat times and cavity temperature recovery times 

will be increased slightly if operating the unit with less 

than a 240 Vac circuit.

• 

This appliance is provided with electrical wiring in a 

flexible metal conduit.

Product Specifications

Model 

Number

Dedicated Circuit 

Requirements

total Connected 

Load

EORS127

240 Vac 60 Hz,  

4 wire*, 30 Amp.

5.0 kW (21 Amp.)

MORS127
EORS130
MORS130
EORS136

5.3 kW (22 Amp.)

EORS227

240 Vac 60 Hz,  

4 wire*, 40 Amp.

7.8 kW (33 Amp.)

MORS227
EORS230
MORS230
EORD227

240 Vac 60 Hz,  

4 wire*, 50 Amp.

10.0 kW (42 Amp.)

MORD227
EORD230
MORD230

* Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above specifications are for reference only. See the 

appliance data plate (page 3) for exact specifications.

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

Model 

Number

Overall 

Width (A)

Chassis 

Width (B)*

Overall 

Height (C)

Chassis 

Height (D)**

Control Panel 

Overlay (E)

EORS127/

MORS127

26 7/8”  

(68.3 cm)

25 3/8”  

(64.5 cm)

28 7/16” 

(72.2 cm)

27 1/2” 

(69.9 cm)

15/16” 

(23.8 cm)

EORS130/

MORS130

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

EORS136

35 7/8”  

(91.1 cm)

34 3/8”  

(87.3 cm)

28 1/8” 

(71.4 cm)

27 1/4” 

(69.2 cm)

7/8”  

(2.2 cm)

EORX227/

MORX227

26 7/8”  

(68.3 cm)

25 3/8”  

(64.5 cm)

49 15/16” 

(126.8 cm)

49 1/16” 

(124.6 cm)

7/8”  

(2.2 cm)

EORX230/

MORX230

29 7/8”  

(75.9 cm)

28 3/8”  

(72.1 cm)

X = Number of convection ovens, see page 3 

*  Width at light covers on sides 

**  To top of chassis notch behind control panel 

Product Dimensions

All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.

Utility 

Cutout 

Width (F)

Utility 

Cutout 

Height (G)

Utility 

Cutout 

Depth (H)

Control 

Panel 

Depth (J)

Notch 

Depth (K)

Chassis 

Depth (L)

Notch 

Height (M)

All Models

5”  

(12.7 cm)

5 1/4” 

(13.3 cm)

6” 

(15.2 cm)

1” 

(2.5 cm)

1 1/8” 

(2.9 cm)

24”  

(61.0 cm)

1” 

(2.5 cm)

Содержание EORD227S

Страница 1: ...Installation Instructions Classic Wall Oven Models EOR MOR Part No 102579 Rev L...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved...

Страница 3: ...Labels 1 General Safety Precautions 2 Customer Service Information 3 If You Need Help 3 Appliance Data Plate 3 Model Identification 3 Product Specifications 4 Power Supply Requirements 4 Product Dime...

Страница 4: ...rd secure the oven to the cabinet using the supplied mounting screws WARNING General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance foll...

Страница 5: ...ou call have the model and serial number of the appliance ready The model and serial number are printed on the appliance data plate Dacor Customer Service Phone 800 793 0093 U S A and Canada Monday Fr...

Страница 6: ...0 kW 21 Amp MORS127 EORS130 MORS130 EORS136 5 3 kW 22 Amp EORS227 240 Vac 60 Hz 4 wire 40 Amp 7 8 kW 33 Amp MORS227 EORS230 MORS230 EORD227 240 Vac 60 Hz 4 wire 50 Amp 10 0 kW 42 Amp MORD227 EORD230...

Страница 7: ...F A K L M E Chassis Notch Side View Control panel front Top of chassis Top of chassis Utility cutout Light cover Light cover Conduit 60 152 cm Long D Design Specifications 3 3 8 8 6 cm 1 2 5 cm 1 2 5...

Страница 8: ...allation so that all minimum clearances are met or exceeded Dimensions shown provide mini mum clearances unless otherwise noted Be certain that proper clearance is provided for the oven door when it i...

Страница 9: ...4 1 9 cm support platform 31 1 4 79 4 cm recommended 1 2 5 cm Min to bottom of cabinet door 1 2 5 cm Min to top of cabinet door 1 1 2 3 8 cm typical counter 1 2 5 cm Min to combustible floor 3 4 1 9...

Страница 10: ...with 2 double ovens come with either 4 or 5 GlideRack oven rack 1 Broil grill and pan Remove the door s to reduce weight and make the oven easier to lift warning Do not attempt to disengage the hinge...

Страница 11: ...the supplied appli ance conduit may be a smaller gage than the standard household wiring of the dedicated supply circuit They are suitable for connection to household wiring under the jurisdiction of...

Страница 12: ...e Wire Electrical System Where Local Codes Permit warning Do not connect the green appliance conduit wire to the neutral white junction box wire unless local building codes permit 1 Separate the wires...

Страница 13: ...be jumped with a minimum 4 AWG wire to establish continuity to ground note If the junction box has been properly grounded by a licensed electrician the green ground wire from the appliance conduit ma...

Страница 14: ...il the rear edge of the oven frame is flush with the cabinet face and the oven is centered within the cut out Ensure that the electrical conduit slides through the opening in the cabinet platform or c...

Страница 15: ...or on opposite sides and lift it until the door hinges are aligned with the openings in the oven frame 2 Holding the door at about a 30 angle from the horizon tal slide the hinges into the openings un...

Страница 16: ...ker or fuse box and check the electrical connections Turn on power and repeat the above heating test If the appliance still does not work contact Dacor Distinctive Service at 877 337 3226 Do not attem...

Страница 17: ...nded according to these instructions and in accordance with all applicable elec trical codes See pages 4 and 9 through 11 Is the oven secured into the cabinet with all the mount ing screws four 4 on s...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: