background image

PLANNING

GUIDE

www.Dacor.com      Phone: (800) 793-0093  

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

4.4

cAbINEt/coUNtErtoP cUtoUt DImENsIoNs wIth rAIsED VENt - toP VIEw

cAbINEt/coUNtErtoP cUtoUt DImENsIoNs 

wIth rAIsED VENt - sIDE VIEw

EG366, EG486

Document # PG04-001

Revised 05/06/10   Page 4/4

Model 

No.

B - Cutout 

Width

D - Hole 

Offset

E - Raised 

Vent Cutout

EG366

36”  

(914 mm)

16 5/8”  

(422 mm)

33 1/2” 

(851 mm)

EG486

48”  

(1219 mm)

20 13/16” 

(529 mm)

43 1/2”  

(1105 mm)

Model 

No.

Approved Raised

Vent Models

EG366

ERV36, PRV36

EG486

ERV48, PRV48

Cutout tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated

Non combustible rear 

wall recommended

10” (254 mm) Min. to 

combustible wall 

above countertop, 

both sides

Cabinet face 

below countertop 

overhang

3/8” (10 mm) Min. 

countertop overhang

2 5/8”

(67 mm)

Hole 1/2” dia. (13 mm), 

2 places, through platform

for hold down bolts 

1/2” (13 mm) 

countertop 

overhang

1” thick mounting platform Min.

Open to below to allow for raised 

vent, gas and electrical connections

Countertop

Countertop

1/2” (13 mm) 

countertop 

overhang

2” (51 mm)

1” (25 mm)

11 7/16” 

(291 mm)

15”

(381 mm)

24 5/8”

(625 mm)

CL

D

D

E

B

CL

CL

CL

Stiffener

Cabinet face

Control panel

Countertop

Dacor approved

raised vent

IMPORTANT: See raised vent

installation instructions for 

duct system layout/planning 

EG366 or EG486 cooktop

3/8” Min. (10 mm)

space behind

raised vent 

chassis to clear

stiffener

3/8” Min. (10 mm)

flat countertop overhang

required behind cutout

Minimum

countertop 

height: 

30 1/4"

(768 mm)

IMPORTANT:

 Use only the raised vents specified.

36 Inch and 48 Inch wide

Epicure

®

 Gas cooktops

Отзывы: