PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
4.1
A
EG366, EG486
ELEctrIc cIrcUIt rEqUIrEmENts
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
GAs sUPPLy PrEssUrE rEqUIrEmENts*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
IMPORTANT:
Installation of a non-combustible material* (up to the hood) or
a backsplash is always recommended, and mandatory if the distance to the
back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a
backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366),
AEB4809 or AEB4812 (EG486).
cAbINEt/coUNtErtoP sIDE VIEw wIthoUt bAckGUArD
cAbINEt/coUNtErtoP sIDE VIEw wIth bAckGUArD
ProDUct DImENsIoNs - sIDE VIEw
ProDUct DImENsIoNs - Iso VIEw
A - Width
EG366
35 7/8” (911 mm)
EG486
47 7/8” (1216 mm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
WARNING
Observe all governing codes and ordinances during planning
•
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
•
accompanying installation instructions.
Document # PG04-001
Revised 05/06/10 Page 1/4
4” (102 mm)
5/8”
(16 mm)
7 3/4”
(197 mm)
Trim:
7/16”
(11 mm)
thick
26” (660 mm)
1 1/2” (38 mm) cooking surface
height (grate level) above
countertop
3/4” gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2” (51 mm) from chassis bottom
27” (686 mm)
28” (711 mm)
Power cord
32” long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (64 mm) Min. to
combustible rear wall
36 Inch and 48 Inch wide
Epicure
®
Gas cooktops