background image

18

Base Grille Water Filtration System (Water Filter)

Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the 

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water 

leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction 

Aesthetic Effects

NSF Reduction 

Requirements

Average  

Influent

Influent Challenge 

Concentration

Maximum 

Effluent

Average 

Effluent

Minimum % 

Reduction

Average % 

Reduction

Chlorine Taste/Odor  

Particulate Class 1*

≥50% 

≥85%

2.1 mg/L 

5,366,667/mL

2.0 mg/L ± 10%

At least 10,000

particles/mL

0.06 mg/L

4,100/mL** 

0.05 mg/L

2,300/mL

97.1%

99.3%

97.6%

99.9%

Contaminant 

Reduction

NSF Reduction 

Requirements

Average  

Influent

Influent Challenge 

Concentration

Maximum 

Effluent

Average 

Effluent

Minimum % 

Reduction

Average % 

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

0.01mg/L

0.01mg/L

0.152 mg/L†

0.143 mg/L†

0.15 mg/L ± 10%

0.15 mg/L ± 10%

0.001 mg/L

0.001 mg/L

0.001 mg/L

0.001 mg/L

99.34%

99.30%

99.34%

99.30%

Mercury: @ pH 6.5

Mercury: @ pH 8.5

0.002 mg/L

0.002 mg/L

0.0061 mg/L

0.0057 mg/L

0.006 mg/L ± 10%

0.0058 mg/L ± 10%

0.0004 mg/L

0.0008 mg/L

0.0003 mg/L

0.00051 mg/L

93.5%

85.8%

96.7%

91.2%

Benzene

0.005 mg/L

0.0162 mg/L

0.015 ± 10%

0.0005 mg/L

0.001 mg/L

96.3%

96.3%

p-dichlorobenzene

0.075 mg/L

0.220 mg/L

0.225 ± 10%

0.0005 mg/L

0.0005 mg/L

99.7%

99.7%

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 ± 10%

0.0014 mg/L

0.001 mg/L

90%

92.96%

Atrazine

0.003 mg/L

0.0086 mg/L

0.009 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

94.25%

94.25%

2, 4-D

0.07 mg/L

0.197 mg/L

0.210 ± 10%

0.058 mg/L

0.0137 mg/L

70.6%

93.06%

Asbestos

99%

26 x 107

107 to 108 fibers/L††

0.18 x 107 mg/L 0.18 x 107 mg/L 99.93%

99.93%

Cysts‡

Turbidity

99.95%

0.5 NTU

111,000/mL

11.00 NTU

50,000/L min.

11 ± 1 NTU

1 mg/L

0.40 NTU

1 mg/L

0.35 NTU

99.99%

96.4%

99.99%

96.8%

Product Data Sheets

* Class I particle size: >0.5 to <1 um  

** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. 

† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. 

†† Fibers greater than 10 um in length 

‡ Based on the use of Cryptosporidium parvum oocysts 

® NSF is a registered trademark of NSF International.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F 

(17.2°C).

Application Guidelines/Water Supply Parameters

Water Supply 

 

City or Well

Water Pressure   

30 - 120 psi (207 - 827 kPa)

Water Temperature 

33° - 100°F (0.6° - 37.8°C) 

Service Flow Rate  

0.5 GPM (1.89 L/min.) @ 60 psi.

Tested and certified by NSF International against ANSI/NSF Standard 42 for 

the reduction of Chlorine Taste and Odor, Particulate Class I*; and against 

ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, 

Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.

It is essential that operational, maintenance, and filter 

 

„

replacement requirements be carried out for the product to 

perform as advertised.
The filter monitor system measures the amount of water that 

 

„

passes through the filter and alerts you to replace the filter. 

When 90% of the filter’s rated life is used, the filter indicator 

light changes from green to yellow. When 100% of the filter’s 

rated life is used, the filter indicator light changes from yellow 

to red, and it is recommended that you replace the filter. Use 

replacement cartridge AFF5. See www.everythingdacor.com.
The product is for cold water use only.

 

„

Содержание EF42DBSS

Страница 1: ...afety 1 Important Information 2 Model Identification 2 Before Use 3 Refrigerator Operation 3 12 Care and Cleaning 13 14 Troubleshooting 15 17 Product Data Sheets 18 Warranty and Service 19 Notes 20 Fr...

Страница 2: ...2008 Dacor all rights reserved...

Страница 3: ...ead and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbo...

Страница 4: ...n of your refrigerator ready These numbers are found on a serial number label located on the right side of the refrigerator liner Record these numbers on this page for easy access Model number _______...

Страница 5: ...ammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your refrigerator For more information see Important Safety Instructions on page 1 Dispose of recycl...

Страница 6: ...st reduction may be used on disinfected waters that may contain filterable cysts Please read before using the water system Follow the directions specific to your model NOTE If your model has a base gr...

Страница 7: ...een both sections any odors formed in one section will transfer to the other You must thoroughly clean both sections to eliminate odors To avoid odor transfer and drying out of food wrap or cover food...

Страница 8: ...hours unless manually turned off NOTE The refrigerator temperature display will remain at 34 F 1 C and the freezer temperature display will remain at 5 F 21 C while the Max Cool feature is on After 24...

Страница 9: ...vances require turning off the lights and ice maker When you select this feature the ice maker will be disabled and the interior lights will turn off The temperature settings remain unchanged On some...

Страница 10: ...and the ice bin Ice moves from the bin and falls through the chute When you release the dispenser lever the trap door closes and the ice dispensing stops The dispensing system will not operate when th...

Страница 11: ...your ice will be only as good as the quality of the water supplied to your ice maker Avoid connecting the ice maker to a softened water supply Water softener chemicals such as salt can damage parts of...

Страница 12: ...shelves and covers are heavy Use both hands when removing them to avoid dropping The shelves and compartments in your refrigerator are adjustable and or removable to meet your individual storage need...

Страница 13: ...ogurt sour cream and cottage cheese have freshness dates on their cartons for appropriate length of storage Store these foods in the original carton and refrigerate immediately after purchasing and af...

Страница 14: ...ne day ahead of time When the last load of ice drops raise the wire shutoff arm to the OFF up position 3 Turn the power off See Turning the Refrigerator On or Off on page 5 4 Clean refrigerator wipe i...

Страница 15: ...directions on the bottle IMPORTANT This cleaner is for stainless steel parts only Do not allow the Stainless Steel Cleaner and Polish to come into contact with any plastic parts such as the trim piec...

Страница 16: ...lush the water system See Flushing the Water System After Replacing Filter Flushing the Water System After Replacing Filter Non dispensing models Turn on the ice maker Allow 24 hours to produce the fi...

Страница 17: ...ain pan Creaking Cracking occurs as ice is being ejected from the ice maker mold Try the solutions suggested here first in order to avoid the cost of an unnecessary service call The motor seems to run...

Страница 18: ...ten the water source line Reverse osmosis water filtration system connected to your cold water supply See Water Supply Requirements Questions remain regarding water pressure Call a licensed qualified...

Страница 19: ...our cold water supply See Water Supply Requirements Water is leaking from the dispenser NOTE One or two drops of water after dispensing is normal Glass not being held under the dispenser long enough H...

Страница 20: ...10 0 058 mg L 0 0137 mg L 70 6 93 06 Asbestos 99 26 x 107 107 to 108 fibers L 0 18 x 107 mg L 0 18 x 107 mg L 99 93 99 93 Cysts Turbidity 99 95 0 5 NTU 111 000 mL 11 00 NTU 50 000 L min 11 1 NTU 1 mg...

Страница 21: ...refrigerator is located in the United States or Canada Refrigerators located elsewhere are covered by the limited warranties only including parts that fail during the first year Warranty is null and...

Страница 22: ...20 Notes...

Страница 23: ......

Страница 24: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: